The single and two-phase flow field of a rotating disc contactor (RDC) extraction column is simulated with the help of computational fluid dynamics (CFD). The simulations were validated by particle image velocimetry (PIV) measurements. The single phase setup was used to test different turbulence models, and a 2D and 3D grid approach. For the two-phase simulations, a 2D computational grid and the Euler-Euler model was used. The two-phase PIV measurements are possible when using an iso-optical system, where the refractive indices of both liquid phases are identical.
In this work, a one-group reduced population balance model based on the one primary and one secondary particle method (OPOSPM) developed recently by Attarakih et al. (
Jezowski
J.
Thullie
J.
Proceedings of the 19th European Symposium on Computer Aided Process Engineering, ESCAPE-19, Cracow, Poland, June 14−17, 2009New York2009978-0-444-53433-0) is implemented in the commercial computational fluid dynamics (CFD) package FLUENT 6.3 for solving the population balance equation in a combined CFD−population balance model (PBM). The one-group reduced population balance conserves the total number (N) and volume (α) concentrations of the population by directly solving two transport equations for N and α and provides a one-quadrature point for closing the unclosed integrals in the population balance equation. Unlike the published two-equation models, the present method offers accuracy improvement and internal consistency (with respect to the continuous population balance equation) by increasing the number of primary particles (sections). The one-group reduced population balance provides the possibility of a one-equation model for the solution of the PBM in CFD based on the mathematically consistent d
30 instead of the classical d
32 mean droplet diameter. Droplet breakage and coalescence are considered in the PBM, which is coupled to the fluid dynamics in order to describe real droplet behavior in a stirred liquid−liquid extraction column. As a case study, a full pilot-plant extraction column of a rotating disk contactor (RDC) type consisting of 50 compartments was simulated with the new model. The predicted results for the mean droplet diameter and the dispersed-phase volume fraction (holdup) agree well with literature data. The results show that the new CFD−PBM model is very efficient from a computational point of view (a factor of 2 less than the QMOM and a factor of 5 less than the method of classes). This is because the one-group reduced population balance requires the solution of only one equation (the total number concentration) when coupled to the CFD solver. It is therefore suitable for fast and efficient simulations of small-scale devices and even large-scale industrial processes.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.