IntroductionThe turnover of Ringer´s solutions is greatly dependent on the physiological situation, such as the presence of dehydration or anaesthesia. The present study evaluates whether the kinetics is affected by previous infusion of colloid fluid.MethodsTen male volunteers with a mean age of 22 years underwent three infusion experiments, on separate days and in random order. The experiments included 10 mL/kg of 6% hydroxyethyl starch 130/0.4 (Voluven™), 20 mL/kg of Ringer's acetate, and a combination of both, where Ringer´s was administered 75 minutes after the starch infusion ended. The kinetics of the volume expansion was analysed by non-linear least- squares regression, based on urinary excretion and serial measurement of blood haemoglobin concentration for up to 420 minutes.ResultsThe mean volume of distribution of the starch was 3.12 L which agreed well with the plasma volume (3.14 L) estimated by anthropometry. The volume expansion following the infusion of starch showed monoexponential elimination kinetics with a half-life of two hours. Two interaction effects were found when Ringer´s acetate was infused after the starch. First, there was a higher tendency for Ringer´s acetate to distribute to a peripheral compartment at the expense of the plasma volume expansion. The translocated amount of Ringer´s was 70% higher when HES had been infused earlier. Second, the elimination half-life of Ringer´s acetate was five times longer when administered after the starch (88 versus 497 minutes, P <0.02).ConclusionsStarch promoted peripheral accumulation of the later infused Ringer´s acetate solution and markedly prolonged the elimination half-life.Trial registrationClinicalTrials.gov: NCT01195025
Brachial plexus block significantly altered [Formula: see text], PVI, and PI, which indicates that regional nervous control of the arm greatly affects plethysmographic measurements obtained by the Radical-7. After the brachial plexus block, [Formula: see text] increased and PVI decreased.
The starch increased COP and only minor capillary leak occurred in healthy volunteers. The fluid-induced plasma dilution correlated with mild impairment of the extrinsic coagulation pathway but not of the intrinsic pathway.
The bias of measuring haemoglobin concentration by pulse oximetry is dependent on whether a crystalloid or a colloid fluid is infused. Trial registration ClinicalTrials identifier: NCT01195025.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.