Different strain values are found between fibrous, fibro-fatty, and fatty plaque components, indicating the potential of intravascular elastography to distinguish different plaque morphologies.
Ultrasound is the most commonly used clinical imaging modality. However, in applications requiring cell-labeling, the large size and short active lifetime of ultrasound contrast agents limit their longitudinal use. Here, 100 nm radius, clinically applicable, polymeric nanoparticles containing a liquid perfluorocarbon, which enhance ultrasound contrast during repeated ultrasound imaging over the course of at least 48 h, are described. The perfluorocarbon enables monitoring the nanoparticles with quantitative 19 F magnetic resonance imaging, making these particles effective multimodal imaging agents. Unlike typical core-shell perfluorocarbon-based ultrasound contrast agents, these nanoparticles have an atypical fractal internal structure. The nonvaporizing highly hydrophobic perfluorocarbon forms multiple cores within the polymeric matrix and is, surprisingly, hydrated with water, as determined from small-angle neutron scattering and nuclear magnetic resonance spectroscopy. Finally, the nanoparticles are used to image therapeutic dendritic cells with ultrasound in vivo, as well as with 19 F MRI and fluorescence imaging, demonstrating their potential for long-term in vivo multimodal imaging.
In this paper we present a computer aided detection (CAD) system for automated measurement of the fetal head circumference (HC) in 2D ultrasound images for all trimesters of the pregnancy. The HC can be used to estimate the gestational age and monitor growth of the fetus. Automated HC assessment could be valuable in developing countries, where there is a severe shortage of trained sonographers. The CAD system consists of two steps: First, Haar-like features were computed from the ultrasound images to train a random forest classifier to locate the fetal skull. Secondly, the HC was extracted using Hough transform, dynamic programming and an ellipse fit. The CAD system was trained on 999 images and validated on an independent test set of 335 images from all trimesters. The test set was manually annotated by an experienced sonographer and a medical researcher. The reference gestational age (GA) was estimated using the crown-rump length measurement (CRL). The mean difference between the reference GA and the GA estimated by the experienced sonographer was 0.8 ± 2.6, −0.0 ± 4.6 and 1.9 ± 11.0 days for the first, second and third trimester, respectively. The mean difference between the reference GA and the GA estimated by the medical researcher was 1.6 ± 2.7, 2.0 ± 4.8 and 3.9 ± 13.7 days. The mean difference between the reference GA and the GA estimated by the CAD system was 0.6 ± 4.3, 0.4 ± 4.7 and 2.5 ± 12.4 days. The results show that the CAD system performs comparable to an experienced sonographer. The presented system shows similar or superior results compared to systems published in literature. This is the first automated system for HC assessment evaluated on a large test set which contained data of all trimesters of the pregnancy.
Background Previous studies have reported on myocardial injury in patients with coronavirus infectious disease 19 (COVID-19) defined as elevated cardiac biomarkers. Whether elevated biomarkers truly represent myocardial dysfunction is not known. The aim of this study was to explore the incidence of ventricular dysfunction and assess its relationship with biomarker analyses. Methods This cross-sectional study ran from April 1 to May 12, 2020, and consisted of all consecutively admitted patients to the Radboud university medical Electronic supplementary material The online version of this article (
Controlling the motion of microrobots based on feedback provided using an imaging modality is essential to make them clinically viable. In this study, we demonstrate the wireless magnetic-based motion control of paramagnetic microparticles using ultrasound feedback. This control is accomplished by pulling the microparticles using the magnetic field gradients towards the reference position through feedback provided by an ultrasound system. First, position of the microparticles is determined using the ultrasound images. Second, calibration of the ultrasound-based tracking of microparticles is achieved and verified using a calibrated microscopic system. Third, the feedback provided by the ultrasound system is used in the implementation of a proportional-derivative magneticbased control system. This control system allows us to achieve point-to-point control of microparticles with an average position tracking error of 48±59 µm, whereas a control system based on a microscopic system achieves an average position tracking error of 21±26 µm. The positioning accuracy accomplished using our ultrasound magnetic-based control system demonstrates the ability to control microrobotic systems in situations where visual feedback cannot be provided via microscopic systems.
Deformations of the atherosclerotic vascular wall induced by the pulsating blood can be estimated using ultrasound strain imaging. Because these deformations indirectly provide information on mechanical plaque composition, strain imaging is a promising technique for differentiating between stable and vulnerable atherosclerotic plaques. This paper first explains 1-D radial strain estimation as applied intravascularly in coronary arteries. Next, recent methods for noninvasive vascular strain estimation in a transverse imaging plane are discussed. Finally, a compounding technique that our group recently developed is explained. This technique combines motion estimates of subsequently acquired focused ultrasound images obtained at various insonification angles. However, because the artery moves and deforms during the multi-angle acquisition, errors are introduced when compounding. Recent advances in computational power have enabled plane wave ultrasound acquisition, which allows 100 times faster image acquisition and thus might resolve the motion artifacts. In this paper the performance of strain imaging using plane wave compounding is investigated using simulations of an artery with a vulnerable plaque and experimental data of a two-layered vessel phantom. The results show that plane wave compounding outperforms 0° focused strain imaging. For the simulations, the root mean squared error reduced by 66% and 50% for radial and circumferential strain, respectively. For the experiments, the elastographic signal-to-noise and contrast-to-noise ratio (SNR(e) and CNR(e)) increased with 2.1 dB and 3.7 dB radially, and 5.6 dB and 16.2dB circumferentially. Because of the high frame rate, the plane wave compounding technique can even be further optimized and extended to 3D in future.
Background: In lung cancer staging, mediastinal lymph nodes are currently aspirated using endobronchial ultrasound transbronchial needle aspiration (EBUS-TBNA) based on size and FDG-PET avidity. EBUS strain elastography (SE) is a new technique that may help predict the presence of malignancy. However, a standardized assessment strategy for EBUS-SE measurement is lacking. Objectives: The aim of this study was to determine the optimal assessment strategy for investigating the predictive value of EBUS-SE in mediastinal lymph nodes. Methods: Two qualitative visual analogue scale strain scores and two semiquantitative strain elastography measurements (a strain histogram and strain ratio) were acquired in 120 lymph nodes of 63 patients with (suspected) lung cancer. The dataset was randomized into an 80% training dataset to determine cut-off values. Performance was consecutively tested on the remaining 20% and the overall dataset. Results: The semiquantitative mean histogram scoring strategy with a cut-off value of 78 (range 0–255) showed the best and most reproducible performance in prediction of malignancy with 93% overall sensitivity, 75% specificity, 69% positive predictive value, 95% negative predictive value, and 82% accuracy. Combining the EBUS-SE mean histogram scoring outcome with PET-CT information increased the post-test probability of disease in relevant clinical scenarios, having a positive test likelihood ratio of 4.16 (95% CI 2.98–8.13) and a negative test likelihood ratio of 0.14 (95% CI 0.04–2.81) in suspicious lymph nodes based on FDG-PET or CT imaging. Conclusions: EBUS-SE can potentially help predict lymph node malignancy in patients with lung cancer. The best semiquantitative assessment method is the mean strain histogram technique.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.