Background Little is known about the performance of the Roche novel severe acute respiratory syndrome coronavirus 2 antibody (anti-SARS-CoV-2) assay. We provide an extensive evaluation of this fully automated assay on the Cobas e801/e602 immunoassay analysers. Methods We assessed the linearity, precision, and throughput of the Roche anti-SARS-CoV-2 assay. Sensitivity was calculated from 349 SARS-CoV-2 polymerase chain reaction (PCR) positive samples; specificity was determined from 715 coronavirus disease 2019 (COVID-19)-naive samples. We examined cross-reactivity against other antibody positive samples (syphilis, RF, ANA, ds-DNA, influenza, dengue, HBV, HCV) and the anti-SARS-CoV-2 kinetics. Results The assay cut-off index (COI) was linear up to 90.8. The inter-assay precision was 2.9% for a negative control (COI=0.1) and 5.1% for a positive control (COI=3.0). Assay time is 18min and results are available 1 minute later; throughput for 300 samples was 76 minutes. Only 1 case positive for HBsAg tested falsely positive; specificity was 99.9%. The assay has a sensitivity of 97.1% 14 days after PCR positivity (POS) and 100% at ≥ 21 days POS; 48.2% of cases had anti-SARS-CoV-2 within 6 days POS. In 11 subjects in whom serum was available prior to a positive antibody signal (COI ≥1.0) the interval between the last negative and first positive COI (time to “sero-conversion”) on average is 3 days (range 1-6 days) and 4 more days (range 1-7) for the anti-SARS-CoV-2 to plateau. Conclusion The Roche anti-SARS-CoV-2 assay shows excellent performance with minimal cross-reactivity from other viral and confounding antibodies. Antibody development and sero-conversion appears quite early.
Background: Subjects with previous COVID-19 have augmented post-vaccination responses. However, the antibody response in COVID-naïve subjects from Southeast Asia is not well known. Methods: 77 COVID-naïve vaccinees were tested with a full antibody panel [spike antibodies (total (T-Ab), IgG, IgM) and neutralizing antibodies (N-Ab)] pre-vaccination, 10 days after dose 1, and 20/40/60/90/120/150/180 days after dose 2. Results: 10 days after dose 1, 67.6% (48/71)/69.0% (49/71) were T-Ab/IgG positive; only 15.5% (11/71)/14.1% (10/71) were N-Ab/IgM positive. While all (100%) subjects had brisk T-Ab, IgG and N-Ab antibody responses 20 days after complete vaccination, only 79.1% (53/67) were IgM positive. At 180 days (n = 8), T-Ab/IgG/N-Ab were still reactive (lowest T-Ab 186 U/mL, IgG 617 AU/mL, N-Ab 0.39 µg/mL), but IgM was negative in all samples. Spike antibody thresholds of T-Ab 74.1 U/mL (r = 0.95) and IgG 916 AU/mL (r = 0.95) corresponded to N-Ab reactivity (>0.3 µg/mL). Non-linear regression analysis showed that N-Ab would decrease to 0.3 µg/mL by 241 days, whereas T-Ab/IgG would need 470/163 days to reach titers of T-Ab/IgG associated with a N-Ab 0.3 µg/mL (76.4 U/mL and 916 AU/mL respectively). Conclusions: The antibody responses of T-Ab, IgG and N-Ab remain high and durable even at 180 days. N-Ab titers are expected to remain reactive up to 241 days post-vaccination.
While sensitivity and specificity are important characteristics for any diagnostic test, the influence of prevalence is equally, if not more, important when such tests are used in community screening. We review the concepts of positive/negative predictive values (PPV/NPV) and how disease prevalence affects false positive/negative rates. In low-prevalence situations, the PPV decreases drastically. We demonstrate how using two tests in an orthogonal fashion can be especially beneficial in low-prevalence settings and greatly improve the PPV of the diagnostic test results.
Background: We evaluated the performance of the Abbott N-terminal pro-brain natriuretic peptide (NT-proBNP) assay against the Roche NT-proBNP immunoassay across two sites. Methods: Precision, linearity, and sensitivity studies were performed. A combined method of comparison and regression analysis was performed between the Roche and Abbott assays using samples from both sites (n = 494). To verify biotin interference, lyophilised biotin powder was reconstituted and spiked into serum samples at two medical decision levels (final concentration 500/4250 ng/mL) and compared to controls. NT-proBNP was also measured in anonymised leftover sera (n = 388) in a cardio-renal healthy population and stratified into three age bands—<50 (n = 145), 50–75 (n = 183) and >75 (n = 60). Results: Between-run precision (CV%) for NT-proBNP was 4.17/4.50 (139.5/142.0 pg/mL), 3.83/2.17 (521.6/506.3), and 4.60/2.51 (5053/4973), respectively. The assay was linear from 0.7–41,501 pg/mL. The limit of blank/quantitation was 1.2/7.9 pg/mL. The assay showed no interference from biotin up to 4250 ng/mL. Passing–Bablok regression analysis showed excellent agreement between the two assays (r = 0.999, 95% CI 0.999 to 0.999, p < 0.0001). The Roche assay had a slightly persistent, negative bias across different levels of NT-proBNP. ESC age cut-offs for diagnosing acute heart failure are applicable for the Abbott assay, with the median NT-proBNP of subjects < 50 years old at 43.0 pg/mL (range 4.9–456 pg/mL), 50–75 years old at 95.1 pg/mL (range 10.5–1079 pg/mL), and >75 years old at 173.1 pg/mL (range 23.2–1948 pg/mL). Conclusion: The Abbott Architect NT-proBNP assay has good performance that agrees with the manufacturer’s specifications. ESC/AHA recommended NT-proBNP age groups for acute heart failure diagnosis are applicable to this assay.
generation TRAb assays. Tozzoli R, et al. [7] compared an automated 3 rd generation TRAb (RAD 120; Radim, Pomezia, Italy) against a second 2 nd generation TRAb immunoassay (Lumitest TRAK human; Brahms, Berlin, Germany). The ROC plot of the 3 rd generation assay was excellent (AUC 0.994), with a lower optimal threshold of 1.25 U/L compared to second generation value of 1.99 U/l. The 3 rd generation assay had a higher sensitivity of 97.6% versus 95.1% for the 2 nd generation assay. The 3 rd generation assay also had greater analytical precision with a faster turnaround time.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.