Azodicarbonamide ADA is used in some countries as a flour bleaching agent and a dough conditioner. However, ADA is prohibited for use as a food additive in Japan. Therefore, it is necessary to establish an efficient and sensitive method to determine ADA in wheat flour. A simple and practical procedure to analyze ADA in wheat flour and prepared flour mixes was developed. ADA was extracted from samples by ultrasonication with acetone. ADA in the solution was derivatized with triphenylphosphine TPP . The ADA-TPP derivative was concentrated and cleaned up using a reversed-phase solid-phase extraction cartridge, and the ADA-TPP derivative was analyzed using HPLC for determination and LC-MS/MS for identification. Good linearity was achieved over the concentration range of 0.25-100 ppm ADA in wheat flour and prepared flour mixes. The mean recoveries from wheat flour and prepared flour mixes fortified at the levels of 1 and 10 ppm ranged from 86.9 to 101.0 , and the coefficients of variation ranged from 1.9 to 3.4 .
A simple and rapid dialysis method was developed for the extraction and purification of four artificial sweeteners, namely, sodium saccharin Sa , acesulfame potassium AK , aspartame APM , and dulcin Du , which are present in various foods. Conventional dialysis uses a membrane dialysis tube approximately 15 cm in length and is carried out over many hours owing to the small membrane area and owing to inefficient mixing. In particular, processed cereal products such as cookies required treatment for 48 hours to obtain satisfactory recovery of the compounds. By increasing the tube length to 55 cm and introducing efficient mixing by inversion at half-hour intervals, the dialysis times of the four artificial sweeteners, spiked at 0.1 g/kg in the cookie, were shortened to 4 hours. Recovery yields of 88.9-103.2 were obtained by using the improved method, whereas recovery yields were low 65. 5-82.0 by the conventional method. Recovery yields of Sa, AK, APM, and Du, spiked at 0.1 g/kg in various foods, were 91.6-100.1, 93.9-100.1, 86.7-100.0 and 88.7-104.7 using the improved method.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.