Tight glycemic control (TGC) has shown benefits but has been difficult to achieve consistently. STAR (Stochastic TARgeted) is a flexible, model-based TGC approach that directly accounts for intra-and interpatient variability with a stochastically derived maximum 5% risk of blood glucose (BG) below 72 mg/dl. This research assesses the safety, efficacy, and clinical burden of a STAR TGC controller modulating both insulin and nutrition inputs in virtual and clinical pilot trials. Methods: Clinically validated virtual trials using data from 370 patients in the SPRINT (Specialized Relative Insulin and Nutrition Titration) study were used to design the STAR protocol and test its safety, performance, and required clinical effort prior to clinical pilot trials. Insulin and nutrition interventions were given every 1-3 h as chosen by the nurse to allow them to manage workload. Interventions were designed to maximize the overlap of the model-predicted (5-95 th percentile) range of BG outcomes with the 72-117 mg/dl band and thus provide a maximum 5% risk of BG <72 mg/dl. Interventions were calculated using clinically validated computer models of human metabolism and its variability in critical illness. Carbohydrate intake (all sources) was selected to maximize intake up to 100% of the American College of Chest Physicians/Society of Critical Care Medicine (ACCP/SCCM) goal (25 kg/kcal/h). Insulin doses were limited (8 U/h maximum), with limited increases based on current rate (0.5-2.0 U/h). Initial clinical pilot trials involved 3 patients covering ~450 h. Approval was granted by the Upper South A Regional Ethics Committee.
Abstract-Tight glycemic control (TGC) is prevalent in critical care. Providing safe, effective TGC has proven very difficult to achieve with clinically derived protocols. The problem is exacerbated by extreme patient variability and the need to minimize clinical effort and burden. These ingredients make an ideal scenario for model-based methods to provide optimised solutions. This paper presents the development, clinically validated virtual trials optimisation, and initial clinical implementation of a stochastic targeted (STAR) TGC method and framework. It is compared to a prior successful, modelderived, less flexible and dynamic TGC protocol (SPRINT). The use of stochastic models to safely forecast a range of glucose outcomes over 1-3 hours ensures better performance, more dynamic use of the range of insulin and nutrition inputs and thus better glycemic performance and safety from hypoglycemia, the latter of which was reduced by 3.0x times. Hence, the paper presents an overall engineering approach to TGC from engineering models to clinical implementation and ongoing clinical practice change.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.