Serological and plasmablast responses and plasmablast-derived IgG monoclonal antibodies (MAbs) have been analysed in three COVID-19 patients with different clinical severities. Potent humoral responses were detected within 3 weeks of onset of illness in all patients and the serological titre was elicited soon after or concomitantly with peripheral plasmablast response. An average of 13.7% and 13.0% of plasmablast-derived MAbs were reactive with virus spike glycoprotein or nucleocapsid, respectively. A subset of anti-spike (10 of 32) and over half of anti-nucleocapsid (19 of 35) antibodies cross-reacted with other betacoronaviruses tested and harboured extensive somatic mutations, indicative of an expansion of memory B cells upon SARS-CoV-2 infection. Fourteen of 32 anti-spike MAbs, including five anti-receptor-binding domain (RBD), three anti-non-RBD S1 and six anti-S2, neutralised wild-type SARS-CoV-2 in independent assays. Anti-RBD MAbs were further grouped into four cross-inhibiting clusters, of which six antibodies from three separate clusters blocked the binding of RBD to ACE2 and five were neutralising. All ACE2-blocking anti-RBD antibodies were isolated from two recovered patients with prolonged fever, which is compatible with substantial ACE2-blocking response in their sera. At last, the identification of non-competing pairs of neutralising antibodies would offer potential templates for the development of prophylactic and therapeutic agents against SARS-CoV-2.
This multicenter, retrospective study included 346 serum samples from 74 patients with coronavirus disease 2019 (COVID-19) and 194 serum samples from non-COVID-19 patients to evaluate the performance of five anti-severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) antibody tests, i.e. two chemiluminescence immunoassays (CLIAs): Roche Elecsys® Anti-SARS-CoV-2 Test (Roche Test) and Abbott SARS-CoV-2 IgG (Abbott Test), and three lateral flow immunoassays (LFIAs): Wondfo SARS-CoV-2 Antibody Test (Wondfo Test), ASK COVID-19 IgG/IgM Rapid Test (ASK Test), and Dynamiker 2019-nCoV IgG/IgM Rapid Test (Dynamiker Test). We found high diagnostic sensitivities (%, 95% confidence interval [CI]) for the Roche Test (97.4%, 93.4–99.0%), Abbott Test (94.0%, 89.1–96.8%), Wondfo Test (91.4%, 85.8–94.9%), ASK Test (97.4%, 93.4–99.0%), and Dynamiker Test (90.1%, 84.3–94.0%) after >21 days of symptom onset. Meanwhile, the diagnostic specificity was 99.0% (95% CI, 96.3–99.7%) for the Roche Test, 97.9% (95% CI, 94.8–99.2%) for the Abbott Test, and 100.0% (95% CI, 98.1–100.0%) for the three LFIAs. Cross-reactivity was observed in sera containing anti-cytomegalovirus (CMV) IgG/IgM antibodies and autoantibodies. No difference was observed in the time to seroconversion detection of the five serological tests. Specimens from patients with COVID-19 pneumonia demonstrated a shorter seroconversion time and higher chemiluminescent signal than those without pneumonia. Our data suggested that understanding the dynamic antibody response after COVID-19 infection and performance characteristics of different serological test are crucial for the appropriate interpretation of serological test result for the diagnosis and risk assessment of patient with COVID-19 infection.
A practical approach to fabricate textured GaNbased light-emitting diodes (LEDs) by nanosphere lithography is presented. By spin coating a monolayer of SiO 2 nanoparticles as the mask, textured LEDs can be fabricated. Both textured p-GaN and textured indium tin oxide LEDs show significant improvement over conventional LEDs without damaging the electrical characteristics. The results show that the method is promising for manufacturing low-cost high-efficient GaN-based LEDs.
The authors report on the 394nm UV light emission from low-temperature sputtered n-ZnO∕SiO2 thin films on top of the p-GaN heterostructure. They compare samples with and without a SiO2 current blocking layer. With a SiO2 layer, electroluminescence spectrum shows a sharp emission peak at 394nm, which is attributed to the recombination of accumulated carriers between n-ZnO∕SiO2 and p-GaN∕SiO2 junctions. As for the sample without a SiO2 layer, a broadband ranging from 400to800nm is observed, which is due to Mg+ deep-level transition in the GaN along with defects in the ZnO layers.
We report the case of a patient who had travelled to Japan and who presented mild respiratory symptoms during the COVID-19 outbreak period. There was transient existence of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) RNA in his oropharynx. The RNA was absent in the six respiratory specimens that were subsequently tested. An anti-SARS-CoV-2 antibody response was absent in the acute and convalescent sera. The reported case indicates that transient colonization of SARS-CoV-2 in the upper respiratory tract is possible without inciting any antibody response against the virus.
To determine clinical performance of the single-target SARS-CoV-2
orf 1ab
reverse transcription-insulated isothermal PCR (RT-iiPCR) assay, the positive percentage agreement between this assay and a laboratory real-time RT-PCR assay was 96.8% (30 of 31; 95% confidence interval [CI], 90.5% - 100%) and the negative percentage agreement was 97.1% (67 of 69; 95% CI, 93.1% - 100%).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.