Continuous ambulatory peritoneal dialysis (CAPD) is used to treat end-stage renal failure in an increasing number of patients. CAPD has an advantage over hemodialysis in that it allows patients greater freedom to perform daily activities; it also provides other clinical benefits. However, the long-term effectiveness of CAPD is limited by complications, which have various causes. Complications with an infectious cause include bacterial peritonitis, tuberculous peritonitis, and infections of the catheter exit site and tunnel. Noninfectious complications include catheter dysfunction, dialysate leakage, hernias, and sclerosing encapsulating peritonitis. Many imaging modalities-radiography, ultrasonography, peritoneal scintigraphy, computed tomography (CT), and magnetic resonance (MR) imaging-are useful for characterizing these complications. CT peritoneography and MR peritoneography are techniques specifically suited to this purpose. Imaging plays a critical role in ensuring that complications are detected early and managed appropriately.
From our results and a review of the literature it is clear that before standards can be set we need to define which facial clefts are sonographically demonstrable. Our data provide information for effective counseling and setting of standards for clinical practice.
To validate the British Society of Thoracic Imaging issued guidelines for the categorisation of chest radiographs for coronavirus disease 2019 (COVID-19) reporting regarding reproducibility amongst radiologists and diagnostic performance. MATERIALS AND METHODS: Chest radiographs from 50 patients with COVID-19, and 50 control patients with symptoms consistent with COVID-19 from prior to the emergence of the novel coronavirus were assessed by seven consultant radiologists with regards to the British Society of Thoracic Imaging guidelines. RESULTS: The findings show excellent specificity (100%) and moderate sensitivity (44%) for guideline-defined Classic/Probable COVID-19, and substantial interobserver agreement (Fleiss' k¼0.61). Fair agreement was observed for the "Indeterminate for COVID-19" (k¼0.23), and "Non-COVID-19" (k¼0.37) categories; furthermore, the sensitivity (0.26 and 0.14 respectively) and specificity (0.76, 0.80) of these categories for COVID-19 were not significantly different (McNemar's test p¼0.18 and p¼0.67). CONCLUSION: An amalgamation of the categories of "Indeterminate for COVID-19" and "Non-COVID-19" into a single "not classic of COVID-19" classification would improve interobserver agreement, encompass patients with a similar probability of COVID-19, and remove the possibility of labelling patients with COVID-19 as "Non-COVID-19", which is the presenting radiographic appearance in a significant minority (14%) of patients.
It has previously been demonstrated that freehand 3D ultrasound can be acquired without a position sensor by measuring the elevational speckle decorrelation from frame to frame. However, this requires that the B-scans contain significant amounts of fully developed speckle. In this paper, we show that this condition is rarely satisfied in scans of real tissue, which instead exhibit fairly ubiquitous coherent scattering. By examining the axial and lateral correlation functions, we propose an heuristic technique to quantify the amount of coherency at each point in the B-scans. This leads to an adapted elevational decorrelation scheme which allows for the coherent scattering. Using the adapted scheme, we demonstrate markedly improved reconstructions of animal tissue in vitro.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.