“…In this section, we first present the modifications we have made to current single wall calibration systems used by Prager et al [17] and Treece et al [22]. We then performed and analyzed a number of calibrations in order to measure the reliability of a calibration using a metric based on the curvature of the criterion function.…”
Section: Improving the Reliability Of Single Wall Calibrationsmentioning
confidence: 99%
See 1 more Smart Citation
“…In this section, we first present the modifications we have made to current single wall calibration systems used by Prager et al [17] and Treece et al [22]. We then performed and analyzed a number of calibrations in order to measure the reliability of a calibration using a metric based on the curvature of the criterion function.…”
Section: Improving the Reliability Of Single Wall Calibrationsmentioning
confidence: 99%
“…We then performed and analyzed a number of calibrations in order to measure the reliability of a calibration using a metric based on the curvature of the criterion function. At the same time, these calibrations were used to compare with the results from Treece et al [22], in order to verify the effectiveness of the modifications we have made to the single wall calibration protocol.…”
Section: Improving the Reliability Of Single Wall Calibrationsmentioning
confidence: 99%
“…The RF vectors were filtered with a 5-10 MHz filter, then envelope detected using a Hilbert transform. Each B-scan's position and orientation was recorded using a Northern Digital Polaris optical tracking system (http://www.ndigital.com), with spatial and temporal calibration performed according to the techniques in [15]. The scanning subject was a joint of beef.…”
Section: Experiments and Resultsmentioning
confidence: 99%
“…software was also used to analyze and display the 3D data and has been described in detail elsewhere [16,17]. All 3D US data acquisition was performed by 1 of 2 experienced Consultant radiologists.…”
Section: Imaging Substudymentioning
confidence: 99%
“…The 3D US dataset was reviewed at the personal computer, the tumour was manually segmented and a series of outlines representing the tumour was produced. Volume measurements were produced from the target outlines for each dataset using the Stradwin software [16,17].…”
Section: Imaging Substudymentioning
confidence: 99%