Normal tissue complication probability (NTCP) models could aid the understanding of dose dependence of radiation-induced toxicities after eye-preserving radiotherapy of choroidal melanomas. We performed NTCP-modeling and established dose-response relationships for visual acuity (VA) deterioration and common late complications after treatments with proton therapy (PT).Design: Retrospective study from single, large referral center.Participants: We considered patients from Nice, France, diagnosed with choroidal melanoma and treated primarily with hypofractionated PT (52 Gy physical dose in 4 fractions). Complete VA deterioration information was available for 1020 patients, and complete information on late complications was available for 991 patients.Methods: Treatment details, dose-volume histograms (DVHs) for relevant anatomic structures, and patient and tumor characteristics were available from a dedicated ocular database. Least absolute shrinkage and selection operator (LASSO) variable selection was used to identify variables with the strongest impact on each end point, followed by multivariate Cox regressions and logistic regressions to analyze the relationships among dose, clinical characteristics, and clinical outcomes.Main Outcome Measures: Dose-response relationship for VA deterioration and late complications.Results: Dose metrics for several structures (i.e., optic disc, macula, retina, globe, lens, ciliary body) correlated with clinical outcome. The near-maximum dose to the macula showed the strongest correlation with VA deterioration. The near-maximum dose to the retina was the only variable with clear impact on the risk of maculopathy, the dose to 20% of the optic disc had the largest impact on optic neuropathy, dose to 20% of cornea had the largest impact on neovascular glaucoma, and dose to 20% of the ciliary body had the largest impact on ocular hypertension. The volume of the ciliary body receiving 26 Gy was the only variable associated with the risk of cataract, and the volume of retina receiving 52 Gy was associated with the risk of retinal detachment. Optic disc-to-tumor distance was the only variable associated with dry eye syndrome in the absence of DVH for the lachrymal gland.Conclusions: VA deterioration and specific late complications demonstrated dependence on dose delivered to normal structures in the eye after PT for choroidal melanoma. VA deterioration depended on dose to a range of structures, whereas more specific complications were related to dose metrics for specific structures. Ophthalmology 2021;128:152-161 ª 2020 by the American Academy of Ophthalmology Supplemental material available at www.aaojournal.org.Eye-preserving proton therapy (PT) is used commonly to treat choroidal melanomas. 1 The ultimate objective of the treatment is to destroy the malignancy without producing complications on adjacent healthy tissues, thereby preserving long-term function. Nonetheless, some structures may be exposed to large doses during treatment, and radiation-induced visual acuity (VA) deteriorati...
Ruthenium-106 (Ru-106) brachytherapy is an established modality for eye-preserving treatment of choroidal melanoma. To achieve optimal treatment outcomes, there should be a balance between tumour control and the risk of healthy tissue toxicity. In this retrospective study, we examined normal tissue complication probability (NTCP) for visual acuity deterioration and late complications to aid the understanding of dose-dependence after Ru-106 treatments. We considered consecutive patients diagnosed with choroidal melanoma and primarily treated at a single institution from 2005–2014. Treatment plans were retrospectively recreated using dedicated software and image guidance to contour the tumour and determine the actual plaque position. Dose distributions were extracted from each plan for all relevant anatomical structures. We considered visual acuity deterioration and late complications (maculopathy, optic neuropathy, ocular hypertension, vascular obliteration, cataract and retinal detachment). Lasso statistics were used to select the most important variables for each analysis. Outcomes were related to dose and clinical characteristics using multivariate Cox regressions analysis. In total, 227 patients were considered and 226 of those were eligible for analysis. Median potential follow-up time was 5.0 years (95% CI: 4.5–6.0). Visual acuity deterioration was related to optic disc-tumour distance and dose metrics from the retina and the macula, with retina V10Gy showing the strongest correlation. Macula V10Gy was the only dose metric impacting risk of maculopathy, while optic disc-tumour distance also proved important. Optic disc V50Gy had the largest impact on optic neuropathy along with optic disc-tumour distance. Optic disc V20Gy was the only variable associated with vascular obliteration. Lens D2% had the largest impact on the risk of cataract along with older age and the largest base dimension. We found no variables associated with the risk of ocular hypertension and retinal detachment. Visual acuity deterioration and most late complications demonstrated dependence on dose delivered to healthy structures in the eye after Ru-106 brachytherapy for choroidal melanomas.
Purpose: Ruthenium-106 (Ru-106) brachytherapy is a common eye-preserving treatment for choroidal melanomas. However, a dose-response model describing the relationship between the actual delivered tumour dose and tumour control has, to the best of our knowledge, not previously been quantified for Ru-106 brachytherapy; we aimed to rectify this. Material and methods: We considered consecutive patients with primary choroidal melanomas, treated with Ru-106 brachytherapy (2005)(2006)(2007)(2008)(2009)(2010)(2011)(2012)(2013)(2014). Dosimetric plans were retrospectively recreated using 3D image-guided planning software. Pre-treatment fundus photographies were used to contour the tumour; post-treatment photographies to determine the accurate plaque position. Patient and tumour characteristics, treatment details, dose volume histograms, and clinical outcomes were extracted. Median follow-up was 5.0 years. The relationship between tumour dose and risk of local recurrence was examined using multivariate Cox regression modelling, with minimum physical tumour dose (D 99% ) as primary dose metric. Results: We included 227 patients with median tumour height and largest base dimension of 4 mm (range 1-12, IQR 3-6) and 11 mm (range 4-23, IQR 9-13). The estimated 3 year local control was 82% (95% CI 77-88). Median D 99% was 105 Gy (range 6-783, IQR 65-138); this was the most significant factor associated with recurrence (p < .0001), although tumour height, combined TTT and Ru-106 brachytherapy, and sex were also significant. The hazard ratio (HR) for a 10 Gy increase in D 99% was 0.87 (95% CI 0.82-0.93). Using biological effective dose in the model resulted in no substantial difference in dose dependence estimates. Robustness cheques with D 1-99% showed D 99% to be the most significant dose metric for local recurrence. Conclusion:The minimum tumour dose correlated strongly with risk of tumour recurrence, with 100 Gy needed to ensure at least 84% local control at 3 years.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.