The capability of an airborne 2-μm integrated path differential absorption (IPDA) lidar for high-accuracy and high-precision active remote sensing of weighted-average column dry-air volume mixing ratio of atmospheric carbon dioxide (XCO2) is demonstrated. A test flight was conducted over the costal oceanic region of the USA to assess instrument performance during severe weather. The IPDA targets CO2 R30 absorption line using high-energy 2-μm laser transmitter. HgCdTe avalanche photodiode detection system is used in the receiver. Updated instrument model included range correction factor to account for platform attitude. Error budget for XCO2 retrieval predicts lower random error for longer sensing column length. Systematic error is dominated by water vapor (H2O) through dry-air number density derivation, followed by H2O interference and ranging related uncertainties. IPDA XCO2 retrieval results in 404.43 ± 1.23 ppm, as compared to 405.49 ± 0.01 ppm from prediction models, using consistent reflectivity and steady elevation oceanic surface target. This translates to 0.26% and 0.30% relative accuracy and precision, respectively. During gradual spiral descend, IPDA results in 404.89 ± 1.19 ppm as compared model of 404.75 ± 0.73 ppm indicating 0.04% and 0.23% relative accuracy, respectively. Challenging cloud targets limited retrieval accuracy and precision to 2.56% and 4.78%, respectively, due to H2O and ranging errors.
The 2-micron wavelength region is suitable for atmospheric carbon dioxide (CO 2 ) measurements due to the existence of distinct absorption feathers for the gas at this particular wavelength. For more than 20 years, researchers at NASA Langley Research Center (LaRC) have developed several high-energy and high repetition rate 2-micron pulsed lasers. This paper will provide status and details of an airborne 2-micron triple-pulse integrated path differential absorption (IPDA) lidar. The development of this active optical remote sensing IPDA instrument is targeted for measuring both CO 2 and water vapor (H 2 O) in the atmosphere from an airborne platform. This presentation will focus on the advancement of the 2-micron triple-pulse IPDA lidar development. Updates on the state-of-the-art triple-pulse laser transmitter will be presented including the status of seed laser locking, wavelength control, receiver telescope, detection system and data acquisition. Future plans for the IPDA lidar system for ground integration, testing and flight validation will also be presented.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.