Systemic lupus erythematosis (SLE) is an autoimmune disease frequently accompanied by the presence of an antiphospholipid antibody (APA). Early referred to as the lupus anticoagulant (LAC), this APA consists of immunoglobulins that are known to interfere with coagulation tests that are phospholipid dependent. Such tests include the partial thromboplastin time (PTT), the activated clotting time (ACT) and may affect the thrombin time (TT). This challenges the cardiac surgical team and the perfusionist responsible for monitoring anticoagulation while performing cardiopulmonary bypass (CPB). A 46-year-old female with a history of SLE, severe mitral insufficiency, an anterior wall myocardial infarction, and the presence of a LAC was admitted for mitral valve surgery. Replacement of the mitral valve was accomplished successfully, utilizing CPB. Anticoagulation was managed using the Hepcon HMS PLUS, a device that calculates an individual's heparin dose response and permits assessment of the heparin concentration throughout the procedure. The patient recovered and was sent home 16 days after surgery.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.