Abstract-This study presents results from a randomized controlled clinical trial of the Mirror Image Movement Enabler (MIME) robotic device for shoulder and elbow neurorehabilitation in subacute stroke patients, including data on the use of its bilateral training mode. MIME incorporates a PUMA 560 robot (Staubli Unimation Inc, Duncan, South Carolina) that applies forces to the paretic limb during unilateral and bilateral movements in three dimensions. Robot-assisted treatment (bilateral, unilateral, and combined bilateral and unilateral) was compared with conventional therapy. Similar to a previous study in chronic stroke, combined unilateral and bilateral robotic training had advantages compared with conventional therapy, producing larger improvements on a motor impairment scale and a measure of abnormal synergies. However, gains in all treatment groups were equivalent at the 6-month follow-up. Combined unilateral and bilateral training yielded functional gains that were similar to the gains from equivalent doses of unilateral-only robotic training, although the combined group had more hypertonia and less movement out of synergy at baseline. Robot-assisted treatment gains exceeded those expected from spontaneous recovery. These results are discussed in light of the need for further device development and continued clinical trials.
Previously, we reported that chronic stroke subjects had significant improvements in isometric strength, free reaching extent, and clinical evaluations of function after training in the mirror-image movement enabler (MIME) robotic device. Our primary goal in this analysis was to investigate the hypothesis that the robotic training promoted improved muscle activation patterns. To this end, we examined the interaction forces, kinematics, and electromyograms recorded during training of eight different movement patterns in active-constrained mode. In this mode, the robot constrained the reaching movements to be toward the target, and the movement velocity was proportional to the force produced along the trajectory. Thirteen chronic stroke subjects trained in MIME for 24 1-h sessions over an eight-week period. Work output was significantly increased by week five in all eight movement patterns. Low-level subjects increased their extent of reach, while high-level subjects increased their speed. Directional errors in force production were reduced in six of eight movement patterns. Electromyographic data provided evidence for improved muscle activation patterns in the four movement patterns that started at tabletop level and ended at shoulder level. In contrast, there was no evidence of improved muscle activation patterns in any of the tabletop movements, with increased activation of antagonists in two movement patterns. This dichotomy may have been related to compensation at the shoulder girdle during movements that remained at tabletop level. A simple biomechanical model will be introduced to demonstrate the likelihood of this possibility.
This paper presents the design, control and performance of a high fidelity four degree-of-freedom wrist exoskeleton robot, RiceWrist, for training and rehabilitation. The RiceWrist is intended to provide kinesthetic feedback during the training of motor skills or rehabilitation of reaching movements. Motivation for such applications is based on findings that show robot-assisted physical therapy aids in the rehabilitation process following neurological injuries. The exoskeleton device accommodates forearm supination and pronation, wrist flexion and extension and radial and ulnar deviation in a compact parallel mechanism design with low friction, zero backlash and high stiffness. As compared to other exoskeleton devices, the RiceWrist allows easy measurement of human joint angles and independent kinesthetic feedback to individual human joints. In this paper, joint-space as well as task-space position controllers and an impedance-based force controller for the device are presented. The kinematic performance of the device is characterized in terms of its workspace, singularities, manipulability, backlash and backdrivability. The dynamic performance of RiceWrist is characterized in terms of motor torque output, joint friction, step responses, behavior under closed loop set-point and trajectory tracking control and display of virtual walls. The device is singularity-free, encompasses most of the natural workspace of the human joints and exhibits low friction, zero-backlash and high manipulability, which are kinematic properties that characterize a high-quality impedance display device. In addition, the device displays fast, accurate response under position control that matches human actuation bandwidth and the capability to display sufficiently hard contact with little coupling between controlled degrees-of-freedom.
Robotic devices for movement therapy are moving closer to becoming commercially available tools for aiding in stroke rehabilitation. Robotic technology offers a range of functions that will augment current clinical practice by leveraging therapists' time, cost effectively extending therapy programs, providing new measures of impairment, and offering new therapy protocols. In this article, we review work from several research laboratories that supports the clinical value of stroke therapy systems. A commercialization effort based on these results is described. We also discuss challenges to achieving clinical acceptance and practical implementation of these devices.
Abstract-This randomized, controlled, multisite Department of Veterans Affairs clinical trial assessed robot-assisted (RA) upper-limb therapy with the Mirror Image Movement Enabler (MIME) in the acute stroke rehabilitation setting. Hemiparetic subjects (n = 54) received RA therapy using MIME for either up to 15 hours (low-dose) or 30 hours (high-dose) or received up to 15 hours of additional conventional therapy in addition to usual care (control). The primary outcome measure was the FuglMeyer Assessment (FMA). The secondary outcome measures were the Functional Independence Measure (FIM), Wolf Motor Function Test, Motor Power, and Ashworth scores at intake, discharge, and 6-month follow-up. Mean duration of study treatment was 8.6, 15.8, and 9.4 hours for the low-dose, high-dose, and control groups, respectively. Gains in the primary outcome measure were not significantly different between groups at follow-up. Significant correlations were found at discharge between FMA gains and the dose and intensity of RA. Intensity also correlated with FMA gain at 6 months. The high-dose group had greater FIM gains than controls at discharge and greater tone but no difference in FIM changes compared with low-dose subjects at 6 months. As used during acute rehabilitation, motor-control changes at follow-up were no less with MIME than with additional conventional therapy. Intensity of training with MIME was positively correlated with motor-control gains.Clinical Trial Registration: ClinicalTrials.gov, NCT00223808, "Assisted Movement Neuro-rehabilitation: VA Multi-site Clinical Trial"; http://www.clinicaltrials.gov/ct2/show/NCT00223808
We evaluated a method for measuring abnormal upper-limb motor performance in post-stroke hemiparetic subjects. A servomechanism (MIME) moved the forearm in simple planar trajectories, directly controlling hand position and forearm orientation. Design specifications are presented, along with system performance data during an initial test of 13 stroke subjects with a wide range of impairment levels. Performance of subjects was quantified by measuring the forces and torques between the paretic limb and the servomechanism as the subjects relaxed (passive), or attempted to generate force in the direction of movement (active). During passive movements, the more severely impaired subjects resisted movement, producing higher levels of negative work than less-impaired subjects and neurologically normal controls. During active movements, the more severely impaired subjects produced forces with larger directional errors, and were less efficient in producing work. These metrics had significant test-retest repeatability. These motor performance metrics can potentially detect smaller within-subject changes than motor function scales. This method could complement currently used measurement tools for the evaluation of subjects during recovery from stroke, or during therapeutic interventions.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.