Background: High power shorter duration (HPSD) ablation seen to increase efficacy and safety treating of atrial fibrillation (AF); however, comparative data between HPSD and low power longer duration (LPLD) ablation are limited. Hypothesis: We thought that HPSD might bring more clinical benefits. The aim of this meta-analysis was to evaluate the clinical benefits of HPSD in patients with AF. Methods: The Medline, PubMed, Embase, and the Cochrane Library databases were searched for studies comparing HPSD and LPLD ablation. Results: Ten trials with 2467 patients were included in the analysis. Pooled analyses demonstrated that HPSD showed a benefit of first-pass pulmonary vein isolation (PVI) (risk ratio [RR]: 1.20; 95% confidence interval [
Background: Limited comparative data are available regarding catheter ablation (CA) of atrial fibrillation (AF) using second-generation cryoballoon (CB-2) vs radiofrequency (RF) ablation in elderly patients (>75-year-old).Hypothesis: CB-2 ablation may demonstrate different outcomes compared with that using RF ablation for elderly patients with AF.Method: Elderly patients with symptomatic drug-refractory AF were included in the study. Pulmonary vein isolation was performed in all patients.Results: A total of 324 elderly patients were included (RF: 176, CB-2:148) from September 2016 to April 2019. The CB-2 was associated with shorter procedure time and left atrial dwell time (112.9 ± 11.1 vs 135.1 ± 9.9 minutes, P < .001; 53.7 ± 8.9 vs 65.1.9 ± 9.0 minutes, P < .001), but marked fluoroscopy utilization (22.1 ± 3.3 vs 18.5 ± 3.6 minutes, P < .001). Complications occurred in 3.3% (CB-2) and 6.2% (RF) of patients with no significant different (P = .307). The length of stay after ablation was shorter, but the costs were higher in the CB-2 group (1.94 vs 2.53 days, P < .001 and 91 132.6 ± 3723.5 vs 81 149.4 ± 6824.1 CNY, P < .001) compared to the RF group. Additionally, the rate of early recurrence of atrial arrhythmia was lower in the CB-2 group (14.2 vs 23.3%, P = .047), but the long-term success rate was similar between two groups.Conclusions: CB-2 is associated with shorter procedure time, left atrial dwell time, and length of stay after ablation, but its costs and fluoroscopy time are greater than the RF group. Moreover, the rate of complications and long-term success are similar between the two groups. K E Y W O R D S atrial fibrillation, costs and long-term outcomes, elderly patients, radiofrequency ablation, second-generation cryoballoon ablation
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.