Background Excessive knee valgus has been strongly suggested as a contributing key factor for anterior cruciate ligament (ACL) injuries. Three-dimensional (3D) motion analysis is considered the “gold standard” to assess joint kinematics, however, this is difficult for on-field assessments and for clinical setting. Purpose To investigate the concurrent validity of 2D measurements of knee valgus angle during cutting in different directions and to explore intra-rater and inter-rater reliability of the 2D measurements. Study Design Descriptive laboratory study Method Seven recreational soccer players participated in this study. Participants performed three trials of cutting maneuvers in three different directions (30º, 60º, and 90º) with the dominant leg. Cutting maneuvers were recorded simultaneously with a video camera and a Vicon TM motion capture system. Knee valgus angle from 2D and 3D measurements at initial contact and at peak vertical ground reaction force (vGRF) were extracted. The Pearson’s correlation was used to explore the relationship between the 2D and 3D measurements, and reliability of the 2D measurements were performed using intraclass correlation coefficients (ICC). Result Significant correlations between 2D and 3D knee valgus measurements were noted for 60º ( r = 0.45) and 90º ( r = 0.77) cutting maneuvers at initial contact. At peak vGRF, significant correlations between 2D and 3D knee valgus measurements were noted for 30º, 60º, and 90º cutting maneuvers (r=0.45, r=0.74, r=0.78), respectively. Good-to-excellent intra-rater and inter-rater reliability of the 2D knee valgus measurements was observed during cutting in all directions (ICCs: 0.821-0.997). Conclusion Moderate-to-strong correlation between 2D and 3D knee valgus measurements during 60°-90° cutting maneuvers, and good-to-excellent intra-rater and excellent inter-rater reliability for the 2D measurements in the present study supports the use of 2D knee valgus measurements in the evaluation of targeted interventions, although the limitations of examining cutting maneuvers using 2D measurement in complex movement still need to be considered. Level of Evidence 3
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.