The most popular sap flow measurement technique uses thermal dissipation probes. Differences in wood characteristics and the natural temperature gradient between probes have affected the accuracy and applicability of the sap flow equation. In addition, the continued heat of the probe can also cause thermal damage to tree tissue. The objectives of this study were to use cyclic heating and calibrate the probes with two species: Pinus bungeana Zucc. And Salix matsudana Koidz., two typical diffuse-porous species. This experiment evaluated a thermal dissipation probe in three heating modes: continuous heating, 10 min heating and 50 min cooling (10/50), and 30 min heating and 30 min cooling (30/30). The heating modes were evaluated on two species. Temperature differences between the heating needle and the control needle under different heating modes and transpiration water consumption (whole-tree weighing method) were observed simultaneously. The sap flow estimation equation under cyclic heating mode was established by analyzing the relationship between the sap flow rate and the values obtained from whole-tree weighing. The results showed that the original equation underestimated sap flow rate of P. bungeana and S. matsudana by 67% and 60%. Under the cyclic heating modes, the modified equations were different from the original equation, and their accuracy was improved. After verification, the corrected equations [Fd = 0.0264K0.738 (P. bungeana, 30/30, R2 = 0.67), Fd = 0.0722K1.113(S. matsudana, 30/30, R2 = 0.60), Fd is the sap flow density, K is temperature coefficient] reduced the influence of the natural temperature gradient on the estimation of sap flow rate, thereby significantly improving the accuracy of sap flow rate estimation. The resulting equation may be more suitable for actual field observations of sap flow in the two tested species. The cyclic heating mode has the potential to measure plant transpiration for extended periods in the field.
This study clarified the characteristics and influencing factors of sap flow in Populus tomentosa Carr. and Salix babylonica L., and verified the applicability of Granier’s original formula for measuring the sap flow of the two species, aimed to provide a basis for the accurate assessment of tree transpiration. P. tomentosa and S. babylonica were used as research objects, their sap flow was measured by the thermal dissipation probe method (TDP), together with changes in meteorological factors and soil water content. Meanwhile, the transpiration of both species was measured by the liquid level equilibrium method (LLE) to verify the applicability of Granier’s original formula. We found that: (1) the sap flow velocity of P. tomentosa and S. babylonica under typical sunny and cloudy conditions showed unimodal or bimodal changes, which were highly significantly correlated with meteorological factors (P < 0.01), but they were all small and poorly correlated with meteorological factors on rainy days. (2) The sap flow velocity of both species was significantly and negatively correlated (P < 0.05) with the daily change in stem and soil water content at 10–20 cm. (3) Compared to that calculated with the LLE method, the sap flows of the two species calculated by the TDP technique using Granier’s original formula were seriously underestimated, with error rates of -60.96% and -63.37%, respectively. The Granier’s correction formulas for P. tomentosa and S. babylonica established by the LLE method were Fd = 0.0287K1.236 (R2 = 0.941) and Fd = 0.0145K0.852 (R2 = 0.904), respectively, and the combined correction formula was Fd = 0.0235K1.080 (R2 = 0.957). It was verified that the errors of sap flow calculated by the specific correction formulas for P. tomentosa and S. babylonica were -6.18% and -5.86%, and those calculated by the combined correction formula were -12.76% and -2.32%, respectively. Therefore, the characteristics of the sap flow velocity of P. tomentosa and S. babylonica on sunny, cloudy and rainy days were different and significantly influenced by meteorological factors. The original Granier’s formula for calculating their sap flow resulted in a large error, but can be measured more accurately by constructing specific correction and combination formulas through the LLE method.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.