Introduction The efficacy of tourniquet use during primary total knee arthroplasty (TKA) is thought to reduce intraoperative blood loss, improve surgical exposure, and optimize cement fixation. Tranexamic acid (TXA) use can decrease postsurgical blood loss and transfusion requirements. This review aimed to appraise the effects of tourniquet use in TKA for patients with tranexamic acid use. Methods A meta-analysis was conducted to identify relevant randomized controlled trials involving TXA plus a tourniquet (TXA-T group) and use of TXA plus no tourniquet (TXA-NT group) in TKA. Web of Science, PubMed, Embase, Cochrane Controlled Trials Register, Cochrane Library, Highwire, CNKI, and Wanfang database were searched from 2010 through October 2021. Results We identified 1720 TKAs (1690 patients) assessed in 14 randomized controlled trials. Compared with the TXA-NT group, the TXA-T group resulted in less intra-operative blood loss (P < 0.00001) and decreased duration of surgery (P < 0.00001), however more hidden blood loss (P = 0.0004) and less knee range of motion (P < 0.00001). No significant differences were found between two groups in terms of decrease in hemoglobin (P = 0.84), total blood loss (P = 0.79), transfusion rate (P = 0.18), drainage volume (P = 0.06), Visual Analogue Scale (VAS) at either the day of surgery (P = 0.2), 1 day (P = 0.25), 2 day (P = 0.39), 3 day (P = 0.21), 5 day (P = 0.21), 7 day (P = 0.06) or 1 month after surgery (P = 0.16), Hospital for Special Surgery (HSS) score at either 7 day (P = 0.10), 1 month (P = 0.08), 3 month (P = 0.22) or 6 month after the surgery (P = 0.92), Knee circumference (P = 0.28), length of hospital (P = 0.12), and complications such as intramuscular venous thrombosis (P = 0.81), deep venous thrombosis (P = 0.10), superficial infection (P = 0.45), deep wound infection (P = 0.64), and delayed wound healing (P = 0.65). Conclusion No big differences could be found by using or not tourniquet when use the TXA, though some benefits are related to operation time and less intra-operative blood loss by using tourniquet and TXA, Using the tourniquet was related to more hidden blood loss and less knee range of motion. More adequately powered and better-designed randomized controlled trials (RCTs) studies with long-term follow-up are required to validate this study.
Background The interscalene brachial plexus block (ISB) is a commonly used nerve block technique for postoperative analgesia in patients undergoing shoulder arthroscopy surgery; however, it is associated with potentially serious complications. The use of suprascapular nerve block (SSNB) has been described as an alternative strategy with fewer reported side effects for shoulder arthroscopy. This review aimed to compare the impact of SSNB and ISB during shoulder arthroscopy surgery. Methods A meta-analysis was conducted to identify relevant randomized controlled trials involving SSNB and ISB during shoulder arthroscopy surgery. Web of Science, PubMed, Embase, Cochrane Controlled Trials Register, Cochrane Library, Highwire, CNKI, and Wanfang database were searched from 2010 through March 2021. Results We identified 1255 patients assessed in 17 randomized controlled trials. Compared with the ISB group, the SSNB group had higher VAS at rest in PACU (P = 0.003), 1 h after operation (P = 0.005), similar pain score 2 h (P = 0.39), 3-4 h (P = 0.32), 6-8 h after operation (P = 0.05), then lower VAS 12 h after operation (P = 0.00006), and again similar VAS 1 day (P = 0.62) and 2 days after operation (P = 0.70). As for the VAS with movement, the SSNB group had higher pain score in PACU (P = 0.03), similar VAS 4-6 h after operation (P = 0.25), then lower pain score 8-12 h after operation (P = 0.01) and again similar VAS 1 day after operation (P = 0.3) compared with the ISB group. No significant difference was found for oral morphine equivalents use at 24 h (P = 0.35), duration of PACU stay (P = 0.65), the rate of patient satisfaction (P = 0.14) as well as the rate of vomiting (P = 0.56), and local tenderness (P = 0.87). However, the SSNB group had lower rate of block-related complications such as Horner syndrome (P < 0.0001), numb (P = 0.002), dyspnea (P = 0.04), and hoarseness (P = 0.04). Conclusion Our high-level evidence established SSNB as an effective and safe analgesic technique and a clinically attractive alternative to interscalene block with the SSNB’S advantage of similar pain control, morphine use, and less nerve block-related complications during arthroscopic shoulder surgery, especially for severe chronic obstructive pulmonary disease, obstructive sleep apnea, and morbid obesity. Given our meta-analysis’s relevant possible biases, we required more adequately powered and better-designed RCT studies with long-term follow-up to reach a firmer conclusion.
Supplemental Digital Content is available in the text
Objective: In this study we concerned on the morphological characteristics of the greater tuberosity of humerus and proposed the double-circle radius ratio as a new predictor for the diagnosis of rotator cuff tears. Methods:This was a retrospective study and patients who visited our hospital and were diagnosed with or without rotator cuff tears via magnetic resonance imaging from January 2018 to July 2021 were enrolled and classified into two groups respectively. In a standard anteroposterior view, the radius of the best-fit circle of humeral head and the radius of the concentric circle passing through the most lateral edge of the greater tuberosity were measured in each shoulder. The ratio of these two radiuses was named as the double-circle radius ratio. Angular parameters including the greater tuberosity angle and the critical shoulder angle were also measured in the anteroposterior view. Independent samples t tests and chi-square tests were used to find significant differences between groups. Significant associations between those measured variables and demographic characteristics were analyzed with simple linear regression analysis. Receiver operating characteristic curves were pictured to determine applied cutoff values by using Youden index. Multivariable-adjusted analysis for the occurrence of rotator cuff tears was carried out by using multiple logistic regression analysis. For all tests a p value of <0.05 was considered statistically significant.Results: One hundred and twelve shoulders with rotator cuff tears and 42 shoulders without rotator cuff tears were included. The mean value of the double-circle radius ratio was significantly larger in shoulders with rotator cuff tears (1.42 AE 0.09 vs. 1.30 AE 0.07, P = 0.000). With simple linear regression analysis, the radiuses of the humeral head and the greater tuberosity were significantly associated with heights and weights. In receiver operating characteristic curves, the largest area was found under the curve of the double-circle radius ratio as 0.846 (95% CI, 0.781-0.911; P = 0.000) with an applied cutoff value as 1.38 (sensitivity, 70.5%; specificity, 88.1%). Multivariable-adjusted analysis showed that a value of the double-circle radius ratio >1.38 resulted in 11.252-fold odds of developing rotator cuff tears (95% CI, 3.388-37.368; P = 0.000). Conclusion:The double-circle radius ratio is significantly larger in patients with rotator cuff tears and could be regarded as an eligible predictor for rotator cuff tears.
Background: The infrapatellar fat pad (IPFP) or Hoffa's fat pad is often resected during total knee arthroplasty in order to improve visibility. However, the management of the IPFP during total knee arthroplasty (TKA) is the subject of an ongoing debate that has no clear consensus. The purpose of this review was to appraise if resection of the IPFP affects clinical outcomes. Methods: We conducted a meta-analysis to identify relevant randomized controlled trials involving infrapatellar fat pad resection and infrapatellar fat pad preservation during total knee arthroplasty in electronic databases, including Web of Science, Embase, PubMed, Cochrane Controlled Trials Register, Cochrane Library, Highwire, CBM, CNKI, VIP, and Wanfang database, up to March 2020. Results: Nine randomized controlled trials, involving 783 TKAs (722 patients), were included in the systematic review. Outcome measures included patellar tendon length (PTL), Insall-Salvati ratio (ISR), rate of anterior knee pain, Knee Society Scores (KSS), and knee range of motion. The meta-analysis identified a trend toward the shortening of the patellar tendon with IPFP resection at 6 months (P = 0.0001) and 1 year (P = 0.001). We found no statistical difference in ISR (P = 0.87), rate of anterior knee pain within 6 months (p = 0.45) and 1 year (p = 0.38), KSS at 1 year (p = 0.77), and knee range of motion within 6 months (p = 0.61) and 1 year (0.46). Conclusion: Based on the available level I evidence, we were unable to conclude that one surgical technique of IPFP can definitively be considered superior over the other. More adequately powered and better-designed randomized controlled trial (RCT) studies with long-term follow-up are required to produce evidence-based guidelines regarding IPFP resection.
Background Despite Vast improvements in technology and surgical technique in total knee arthroplasty (TKA), approximately 15–25% TKAs, have suboptimal subjective clinical outcomes. Our study sought to evaluate if sensor-guided balancing improves postoperative clinical outcomes compared to a conventional gap balancing technique. Methods We searched Web of Science, Embase, PubMed, Cochrane Controlled Trials Register, Cochrane Library, Highwire, CBM, CNKI, VIP, and Wanfang database in March 2022 to identify studies involving sensor-guided balancing versus conventional gap balancing technique in TKA. Finally, we identified 2147 knees assessed in nine studies. Results Compared with manual gap balancing, Sensor-guided gap balancing resulted in less rate of Manipulation under anesthesia (MUA) (P = 0.02), however more rate of intraoperative additional procedures (P = 0.0003). There were no significant differences in terms of KSS (P = 0.21), KSS Function score (P = 0.36), OKS (P = 0.61), KOOS (P = 0.78), operative time (P = 0.17), Mechanical axis (P = 0.69) and rate of reoperation between two groups. Conclusion Compared with conventional manual gap balancing techniques, sensors have more balancing procedures being performed. However, it did result in a reduction in the rate of MUA. More extensive, high-quality RCTs are required to verify our findings further.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
334 Leonard St
Brooklyn, NY 11211
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.