Loss of orbital content can cause functional impairment, disfigurement of the face, and psychological distress. Rehabilitation of an orbital defect is a complex task, and if reconstruction by plastic surgery is not possible or not desired by the patient, the defect can be rehabilitated by an orbital prosthesis. The prosthetic rehabilitation in such cases depends on the precisely retained, user-friendly removable maxillofacial prosthesis. Many times, making an impression of the orbital area with an accurate record of surface details can be a difficult procedure. The critical areas are making a facial moulage, mold preparation, and attaching the retention device, particularly when eyeglass frames are used. This case focuses on these hindrance factors. A simple basket was used for the impression tray to obtain the facial moulage. A putty mold was used, and attachment of the prosthesis to a retention device was accomplished with positional distance. This method proves to be an economical and simple way of making an orbital prosthesis.
Hanau spring bow has been in use since 1986. Hanau spring bow is claimed to maintain self centering property when it is positioned in the patient as well as in the articulator. However there is no documented evidence to prove that feature. Mainly it was due to the absence of a testing device. Exclusively for the present study, the testing device consisting of a platform, stops and distance measuring system was designed by the third author. This study proved that Hanau has the capability of self centering.
Conventional beading and boxing procedure is time consuming and involves application of heat that might distort green stick compound used for border molding. Earlier studies regarding beading and boxing methods have shown usage of various materials that were disposable and that cannot be recycled. To reduce the time consumed for beading and boxing procedure and to make this procedure cost-effective by using recyclable beading material, "Preformed boxing appliance" with moldable clay meant for beading the secondary impression was used. Secondary impression was supported by 3 studs provided on the floor of the boxing appliance. The cast was poured. The duration for the entire procedure was much less than the conventional procedure.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.