Résumé. Le Laboratoire Charles Fabry conçoit de nombreuses optiques dont certaines pour les applications dans le spectre EUV. Pour les besoins de caractérisation, il est nécessaire de posséder une métrologie à la longueur d'onde d'utilisation proche des moyens de fabrication. Ceci permet d'étudier les composants dès leur conception et de caractériser les optiques. Nous présentons ici les performances d'un réflectomètre automatisé EUV large spectre. Il a été développé dans le cadre de la centrale CEMOX 1 , initiée par le pôle PRaXO 2 .
Irradiation experiments were conducted at Prague Asterix Laser System (PALS) with the Ne-like zinc soft x-ray laser (SXRL) at 21.2 nm (58.5 eV) delivering up to 4 mJ (~4 x 10 14 photons), 100-ps pulses in a narrowly collimated beam. The SXRL beam was focused using a 1 inch diameter off-axis parabolic mirror (f = 253 mm at 14 degrees) with a Mo:Si multilayer coating (R = 30% at 21.2 nm) placed 2825 mm from the SXRL. The diameter of the SXRL beam incident on the mirror was about 11 mm. Ablation experiments with a gradually attenuated beam were performed to determine the single-shot damage threshold of various materials. In this case, the sample was positioned at the tightest focus of the SXRL whose pulse energy was attenuated by aluminum filters of various thickness to adjust the fluence. Both the focal spot area and single-shot damage threshold were determined from the plot of damaged surface areas as a function of pulse energy logarithm. For PMMA, the focal spot area and the ablation threshold inferred from the data are S foc = 1172 Pm 2 and F th = 1.25 J/cm 2 , respectively. Inorganic materials have thresholds significantly higher than organic polymers, e.g., amorphous and monocrystalline silicon gave values 2.5 J/cm 2 and 4.2 J/cm 2 , respectively. For prospective SASE FEL optical elements, the SiC coating is of great interest. Its damage threshold is of 20 J/cm 2 , i.e., slightly lower than that of monocrystalline silicon. The thresholds determined with the 100-ps pulses from the plasma-based, quasi-steady state SXRL are significantly higher than the thresholds obtained for 20-fs pulses provided by the SXR free-electron laser in Hamburg. There is a difference in PMMA thresholds of two orders of magnitude for these two sources.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.