Background New consumer health devices are being developed to easily monitor multiple physiological parameters on a regular basis. Many of these vital sign measurement devices have yet to be formally studied in a clinical setting but have already spread widely throughout the consumer market. Objective The aim of this study was to investigate the accuracy and precision of heart rate (HR), systolic blood pressure (SBP), diastolic blood pressure (DBP), and oxygen saturation (SpO2) measurements of 2 novel all-in-one monitoring devices, the BodiMetrics Performance Monitor and the Everlast smartwatch. Methods We enrolled 127 patients (>18 years) from the Thomas Jefferson University Hospital Preadmission Testing Center. SBP and HR were measured by both investigational devices. In addition, the Everlast watch was utilized to measure DBP, and the BodiMetrics Performance Monitor was utilized to measure SpO2. After 5 min of quiet sitting, four hospital-grade standard and three investigational vital sign measurements were taken, with 60 seconds in between each measurement. The reference vital sign measurements were calculated by determining the average of the two standard measurements that bounded each investigational measurement. Using this method, we determined three comparison pairs for each investigational device in each subject. After excluding data from 42 individuals because of excessive variation in sequential standard measurements per prespecified dropping rules, data from 85 subjects were used for final analysis. Results Of 85 participants, 36 (42%) were women, and the mean age was 53 (SD 21) years. The accuracy guidelines were only met for the HR measurements in both devices. SBP measurements deviated 16.9 (SD 13.5) mm Hg and 5.3 (SD 4.7) mm Hg from the reference values for the Everlast and BodiMetrics devices, respectively. The mean absolute difference in DBP measurements for the Everlast smartwatch was 8.3 (SD 6.1) mm Hg. The mean absolute difference between BodiMetrics and reference SpO2 measurements was 3.02%. Conclusions Both devices we investigated met accuracy guidelines for HR measurements, but they failed to meet the predefined accuracy guidelines for other vital sign measurements. Continued sale of consumer physiological monitors without prior validation and approval procedures is a public health concern.
Part of the Anesthesiology Commons This Article is brought to you for free and open access by the Jefferson Digital Commons. The Jefferson Digital Commons is a service of Thomas Jefferson University's Center for Teaching and Learning (CTL). The Commons is a showcase for Jefferson books and journals, peer-reviewed scholarly publications, unique historical collections from the University archives, and teaching tools. The Jefferson Digital Commons allows researchers and interested readers anywhere in the world to learn about and keep up to date with Jefferson scholarship. This article has been accepted for inclusion in Phase 1 by an authorized administrator of the Jefferson Digital Commons.
Background: The benefits and challenges of successful breastfeeding for both mother and child have been well-established in the literature. While ankyloglossia, or tongue tie, alone or in combination with upper lip tie has been the focus of several previous studies, very few have directly addressed isolated symptomatic upper lip tie and the role of surgical correction for breastfeeding difficulties.Materials and methods: Seven infants with isolated upper lip tie and breastfeeding difficulty were taken to the operating room for labial frenotomy. These infants were assessed at their follow-up visits for their degree of weight gain since their procedure. Their mothers were surveyed regarding their experiences with breastfeeding since the frenotomy was performed.Results: In this article, we present seven infants with isolated upper lip tie and breastfeeding difficulty who were treated with labial frenotomy. Subsequently, these infants demonstrated improved weight gain, and all mothers reported increased ease of breastfeeding.Conclusion: These findings implicate lip tie as an underrecognized cause of breastfeeding difficulty and suggest that labial frenotomy is an effective treatment in these patients. Larger-scale randomized controlled studies are necessary to further evaluate this topic.
Introduction Despite the presence of a growing body of literature suggesting cost-ineffectiveness of routine pathologic analysis of tonsillectomy specimens, little is known about common institutional policies and practice patterns of pediatric otolaryngologists. The objectives of this study were to determine the prevalence of routine pathological evaluation of tonsillectomy specimens for uncomplicated pediatric adenotonsillectomy procedures and to evaluate opinions regarding this controversy among board-certified pediatric otolaryngologists. Methods This was a cross-sectional survey study sent to board-certified pediatric otolaryngologists currently practicing and registered with the American Society of Pediatric Otolaryngology (ASPO) assessing their institutions’ or practices’ current policies on sending routine tonsillectomy specimens for pathology, their experience with this practice, and their opinions on whether routine pathologic analysis should be employed. Basic statistical analysis was then conducted. Results Respondents mostly practiced in an academic setting (68.4%), with the next most common being academically affiliated private practice (21.8%), and private practice was the least common (9.8%). Most respondents (85.1%) did not agree with routine pathologic analysis of otherwise uncomplicated pediatric tonsillectomy specimens. Conclusion Most pediatric otolaryngologists who responded to this survey do not support routine pathological analysis of otherwise uncomplicated pediatric tonsillectomy specimens. However, the results are likely biased and should be interpreted carefully, since only a small percentage of pediatric otolaryngologists responded to the survey. Potential cost savings could be seen by patients, payers, and hospital systems with judicious use of surgical pathology, specifically in cases with concurrent signs or symptoms suspicious for malignancy.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.