Introduction: Age-related changes in muscle mass and muscle tissue composition contribute to diminished strength in older adults. The objectives of this study are to examine if an assessment method using mobile diagnostic ultrasound augments well-known determinants of lean body mass (LBM) to aid sarcopenia staging, and if a sonographic measure of muscle quality is associated with muscle performance.Methods: Twenty community-dwelling female subjects participated in the study (age = 43.4 ± 20.9 years; BMI: 23.8, interquartile range: 8.5). Dual energy X-ray absorptiometry (DXA) and diagnostic ultrasound morphometry were used to estimate LBM. Muscle tissue quality was estimated via the echogenicity using grayscale histogram analysis. Peak force was measured with grip dynamometry and scaled for body size. Bivariate and multiple regression analyses were used to determine the association of the predictor variables with appendicular lean mass (aLM/ht2), and examine the relationship between scaled peak force values and muscle echogenicity. The sarcopenia LBM cut point value of 6.75 kg/m2 determined participant assignment into the Normal LBM and Low LBM subgroups.Results: The selected LBM predictor variables were body mass index (BMI), ultrasound morphometry, and age. Although BMI exhibited a significant positive relationship with aLM/ht2 (adj. R2 = 0.61, p < 0.001), the strength of association improved with the addition of ultrasound morphometry and age as predictor variables (adj. R2 = 0.85, p < 0.001). Scaled peak force was associated with age and echogenicity (adj. R2 = 0.53, p < 0.001), but not LBM. The Low LBM subgroup of women (n = 10) had higher scaled peak force, lower BMI, and lower echogenicity values in comparison to the Normal LBM subgroup (n = 10; p < 0.05).Conclusions: Diagnostic ultrasound morphometry values are associated with LBM, and improve the BMI predictive model for aLM/ht2 in women. In addition, ultrasound proxy measures of muscle quality are more strongly associated with strength than muscle mass within the study sample.
Background. Quantitative diagnostic ultrasound imaging has been proposed as a method of estimating muscle quality using measures of echogenicity. The Rectangular Marquee Tool (RMT) and the Free Hand Tool (FHT) are two types of editing features used in Photoshop and ImageJ for determining a region of interest (ROI) within an ultrasound image. The primary objective of this study is to determine the intrarater and interrater reliability of Photoshop and ImageJ for the estimate of muscle tissue echogenicity in older adults via grayscale histogram analysis. The secondary objective is to compare the mean grayscale values obtained using both the RMT and FHT methods across both image analysis platforms.Methods. This cross-sectional observational study features 18 community-dwelling men (age = 61.5 ± 2.32 years). Longitudinal views of the rectus femoris were captured using B-mode ultrasound. The ROI for each scan was selected by 2 examiners using the RMT and FHT methods from each software program. Their reliability is assessed using intraclass correlation coefficients (ICCs) and the standard error of the measurement (SEM). Measurement agreement for these values is depicted using Bland-Altman plots. A paired t-test is used to determine mean differences in echogenicity expressed as grayscale values using the RMT and FHT methods to select the post-image acquisition ROI. The degree of association among ROI selection methods and image analysis platforms is analyzed using the coefficient of determination (R2).Results. The raters demonstrated excellent intrarater and interrater reliability using the RMT and FHT methods across both platforms (lower bound 95% CI ICC = .97–.99, p < .001). Mean differences between the echogenicity estimates obtained with the RMT and FHT methods was .87 grayscale levels (95% CI [.54–1.21], p < .0001) using data obtained with both programs. The SEM for Photoshop was .97 and 1.05 grayscale levels when using the RMT and FHT ROI selection methods, respectively. Comparatively, the SEM values were .72 and .81 grayscale levels, respectively, when using the RMT and FHT ROI selection methods in ImageJ. Uniform coefficients of determination (R2 = .96–.99, p < .001) indicate strong positive associations among the grayscale histogram analysis measurement conditions independent of the ROI selection methods and imaging platform.Conclusion. Our method for evaluating muscle echogenicity demonstrated a high degree of intrarater and interrater reliability using both the RMT and FHT methods across 2 common image analysis platforms. The minimal measurement error exhibited by the examiners demonstrates that the ROI selection methods used with Photoshop and ImageJ are suitable for the post-acquisition image analysis of tissue echogenicity in older adults.
Estimates of muscle tissue composition may have greater prognostic value than lean body mass levels regarding health-related outcomes. Ultrasound provides a relatively low cost, safe, and accessible mode of imaging to assess muscle morphology. The purpose of this study was to determine the construct validity of muscle echogenicity as a surrogate measure of muscle quality in a sample of older, predominantly African American (AA) participants. We examined the association of rectus femoris echogenicity with mid-thigh computed tomography (CT) scan estimates of intra- and intermuscular adipose tissue (IMAT), basic metabolic parameters via blood sample analysis, muscle strength, and mobility status. This observational study was conducted at a federal medical center and included 30 community-dwelling men (age, 62.5 ± 9.2; AA, n = 24; Caucasian, n = 6). IMAT estimates were significantly associated with echogenicity (r = 0.73, p < 0.001). Echogenicity and IMAT exhibited similar associations with the two-hour postprandial glucose values and high-density lipoproteins values (p < 0.04), as well as grip and isokinetic (180°/s) knee extension strength adjusted for body size (p < 0.03). The significant relationship between ultrasound and CT muscle composition estimates, and their comparative association with key health-related outcomes, suggests that echogenicity should be further considered as a surrogate measure of muscle quality.
Background. Quantitative ultrasound measures are influenced by multiple external factors including examiner scanning force. Force feedback may foster the acquisition of reliable morphometry measures under a variety of scanning conditions. The purpose of this study was to determine the reliability of force-feedback image acquisition and morphometry over a range of examiner-generated forces using a muscle tissue-mimicking ultrasound phantom.Methods. Sixty material thickness measures were acquired from a muscle tissue mimicking phantom using B-mode ultrasound scanning by six examiners with varied experience levels (i.e., experienced, intermediate, and novice). Estimates of interrater reliability and measurement error with force feedback scanning were determined for the examiners. In addition, criterion-based reliability was determined using material deformation values across a range of examiner scanning forces (1–10 Newtons) via automated and manually acquired image capture methods using force feedback.Results. All examiners demonstrated acceptable interrater reliability (intraclass correlation coefficient, ICC = .98, p < .001) for material thickness measures obtained using force feedback. Individual examiners exhibited acceptable reliability with the criterion-based reference measures (ICC > .90, p < .001), independent of their level of experience. The measurement error among all examiners was 1.5%–2.9% across all applied stress conditions.Conclusion. Manual image capture with force feedback may aid the reliability of morphometry measures across a range of examiner scanning forces, and allow for consistent performance among examiners with differing levels of experience.
Objectives-Assessing aging muscle through estimates of muscle heterogeneity may overcome some of the limitations of grayscale analyses. The objectives of this study included determining statistical model parameters that characterize muscle echogenicity and are associated with strength in younger and older participants.Methods-Thirty-three community-dwelling participants were assigned to younger and older groups. Quantitative B-mode ultrasound scanning of the rectus femoris and isometric grip strength testing were completed. Shape or dispersion parameters from negative binomial distribution, Nakagami, gamma, and gamma mixture models were fitted to the grayscale histograms.Results-The mean ages ± SDs of the younger and older groups were 24.0 ± 2.3 and 65.1 ± 6.5 years, respectively. Statistical model shape and dispersion parameters for the grayscale histograms significantly differed between the younger and older participants (P = .002-.006). Among all of the statistical models considered, the gamma mixture model showed the best fit with the grayscale histograms (χ 2 goodness of fit = 62), whereas the Nakagami distribution displayed the poorest fit (χ 2 goodness of fit = 2595). Grayscale values were significantly associated with peak grip strength force in younger adult participants (R 2 = 0.36; P < .008). However, the negative binomial dispersion parameter k (adjusted R 2 = 0.70; P < .001) and gamma shape parameter α (adjusted R 2 = 0.68; P < .01) showed the highest associations with peak grip strength force in older adult participants.Conclusions-The negative binomial dispersion parameter k and the gamma shape parameter α have clinical relevance for the assessment of age-related muscle changes. Statistical models of muscle heterogeneity may characterize the association between muscle tissue composition estimates and strength better than grayscale measures in samples of community-dwelling older adults.
Following publication of the ultrasound practitioner (UP) master's degree educational proposal in August 1999, the UP Commission published a questionnaire to obtain feedback from SDMS membership to the UP concept. This article contains the results of that data collection. Additionally, as progress has been made in the development of UP programs around the country, refinement of the curriculum, as originally proposed, has begun. This article contains a breakdown of required didactic and clinical education for the midlevel provider in diagnostic ultrasound.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.