Static and dynamic contrast-enhanced MR imaging, when added to nonenhanced MR imaging, improved differentiation between benign and malignant soft-tissue lesions.
The present study aimed to investigate (1) the association between left ventricular diastolic dysfunction (LVDD), graded according to the algorithm proposed by the Cirrhotic Cardiomyopathy Consortium, and long‐term survival in patients with cirrhosis undergoing transjugular intrahepatic portosystemic shunt (TIPS) and (2) the additive prognostic value of left atrial (LA) function, as assessed by LA reservoir strain, using two‐dimensional speckle‐tracking echocardiography (2D‐STE). A total of 129 TIPS candidates (mean ± SD, 61 ± 12 years; 61% men) underwent a comprehensive preprocedural echocardiography. LA dysfunction was defined by LA reservoir strain ≤35%, based on a previously suggested cut‐off value. The outcome was all‐cause mortality after TIPS. In the current cohort, 65 (50%) patients had normal diastolic function, 26 (20%) patients had grade 1 LVDD, 21 (16%) patients had grade 2 LVDD, and 17 (13%) patients had indeterminate diastolic function. Additionally, LA dysfunction (based on LA reservoir strain ≤35%) was noted in 67 (52%) patients. After a median follow‐up of 36 months (range, 12–80), 65 (50%) patients died. All‐cause mortality rates increased along worse grades of LVDD (log‐rank p = 0.007) and with LA dysfunction (log‐rank p = 0.001). On multivariable Cox regression analysis, Model for End‐Stage Liver Disease score (hazard ratio [HR],1.06; p = 0.003), hemoglobin (HR, 0.74; p = 0.022), and LA strain, expressed as a continuous variable (HR, 0.96; p = 0.005) were independently associated with all‐cause mortality. Notably, the addition of LA strain to the model provided incremental prognostic value over the established prognostic variables (delta χ2 = 8.27, p = 0.004). Conclusion: LA dysfunction assessed with 2D‐STE is independently associated with all‐cause mortality in patients with cirrhosis treated by TIPS.
In assessing the severity of lower extremity arterial disease (LEAD), physicians rely on clinical judgements supported by conventional measurements of macrovascular blood flow. However, current diagnostic techniques provide no information about regional tissue perfusion and are of limited value in patients with chronic limb-threatening ischemia (CLTI). Near-infrared (NIR) fluorescence imaging using indocyanine green (ICG) has been used extensively in perfusion studies and is a possible modality for tissue perfusion measurement in patients with CLTI. In this prospective cohort study, ICG NIR fluorescence imaging was performed in patients with CLTI and control patients using the Quest Spectrum Platform® (Middenmeer, The Netherlands). The time–intensity curves were analyzed using the Quest Research Framework. Fourteen parameters were extracted. Successful ICG NIR fluorescence imaging was performed in 19 patients with CLTI and in 16 control patients. The time to maximum intensity (seconds) was lower for CLTI patients (90.5 vs. 143.3, p = 0.002). For the inflow parameters, the maximum slope, the normalized maximum slope and the ingress rate were all significantly higher in the CLTI group. The inflow parameters observed in patients with CLTI were superior to the control group. Possible explanations for the increased inflow include damage to the regulatory mechanisms of the microcirculation, arterial stiffness, and transcapillary leakage.
The goal of our study was to determine the influence of ultrasound (US)-coupled volume navigation on the use of computed tomography (CT) during minimally-invasive radiofrequency and microwave ablation procedures of liver lesions. Method: Twenty-five patients with 40 liver lesions of different histological origin were retrospectively analysed. Lesions were ablated following standard protocol, using 1) conventional US-guidance, 2) manual registered volume navigation (mVNav), 3) automatic registered (aVNav) or 4) CT-guidance. In case of ultrasonographically inconspicuous lesions, conventional US-guidance was abandoned and mVNav was used. If mVNav was also unsuccessful, the procedure was either continued with aVNav or CT-guidance. The number, size and location of the lesions targeted using the different approaches were documented. Results: Of the 40 lesions, sixteen (40.0 %) could be targeted with conventional US-guidance only, sixteen (40.0 %) with mVNav, three (7.5 %) with aVNav and five (12.5 %) only through the use of CT-guidance. Of the three alternatives (mVNav, aVNav and CT only) the mean size of the lesions targeted using mVNav (9.1 ± 4.6 mm) was significantly smaller from those targeted using US-guidance only (20.4 ± 9.4 mm; p < 0.001). The location of the lesions did not influence the selection of the modality used to guide the ablation. Conclusions: In our cohort, mVNav allowed the ablation procedure to become less dependent on the use of CT. mVNav supported the ablation of lesions smaller than those that could be ablated with US only and doubled the application of minimally-invasive US-guided ablations.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.