Summary
Measurement of BCR activator of RhoGEF and GTPase ‐ABL proto‐oncogene 1, non‐receptor tyrosine kinase (BCR‐ABL1) mRNA levels by reverse transcription quantitative polymerase chain reaction (RTqPCR) has been critical to treatment protocols and clinical trials in chronic myeloid leukaemia; however, interlaboratory variation remains a significant issue. Reverse transcriptase droplet digital PCR (RTddPCR) has shown potential to improve testing but a large‐scale interlaboratory study is required to definitively establish this. In the present study, 10 BCR‐ABL1‐positive samples with levels ranging from molecular response (MR)1·0–MR5·0 were tested by 23 laboratories using RTddPCR with the QXDX BCR‐ABL %IS kit. A subset of participants tested the samples using RTqPCR. All 23 participants using RTddPCR detected BCR‐ABL1 in all samples to MR4·0. Detection rates for deep‐response samples were 95·7% at MR4·5, 78·3% at MR4·7 and 87·0% at MR5·0. Interlaboratory coefficient of variation was indirectly proportional to BCR‐ABL1 level ranging from 29·3% to 69·0%. Linearity ranged from 0·9330 to 1·000 (average 0·9936). When results were compared for the 11 participants who performed both RTddPCR and RTqPCR, RTddPCR showed a similar limit of detection to RTqPCR with reduced interlaboratory variation and better assay linearity. The ability to detect deep responses with RTddPCR, matched with an improved linearity and reduced interlaboratory variation will allow improved patient management, and is of particular importance for future clinical trials focussed on achieving and maintaining treatment‐free remission.
Molecular tests have become an indispensable tool for the diagnosis and prognosis of hematological malignancies and are subject to accreditation according to the International Standard ISO 15189. National standardization of these techniques is essential to ensure that patients throughout France benefit from the same care. We report here on the experience of the GBMHM (Groupe des Biologistes Moléculaires des Hémopathies Malignes). By organizing External Evaluation of Quality (EEQ) programs and training meetings, the GBMHM has contributed to improvement and standardization of molecular tests in 64 French laboratories. A retrospective analysis of the quality-control results of 11 national campaigns spanning 10 years was performed for the 3 most frequently prescribed tests: BCR-ABL1, JAK2 V617F, and lymphoid clonality. For each test, particular attention was placed on comparing methodologies and their evolution throughout the period. The establishment of the BCR-ABL1, JAK2 V617F, and lymphoid clonality EEQ programs and the associated training meetings have initiated a process of collective standardization concerning the methods of implementation (JAK2 V617F) and the interpretation and formulation of results (lymphoid clonality). In addition, it resulted in objective improvement in technical performance (BCR-ABL1). Our evaluation of the impact of these EEQ programs demonstrates that it is possible to obtain reproducible values across different laboratories in France by applying national recommendations. To our knowledge, this is the first publication that evaluates the impact of a national quality assurance program on improving molecular results in hematology.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.