The mechanical properties and the thickness of the resin cement agents used for bonding inlay bridges can modify the clinical performance of the restoration such as debonding or prosthetic materials fracture. Thus, the aim of this study was to evaluate the stress distribution and the maximum strain generated by resin cements with different elastic moduli and thicknesses used to cement resin-bonded fixed partial denture (RBFPD). A three-dimensional (3D) finite element analysis (FEA) was used, and a 3D model was created based on a Cone-Beam Computed Tomography system (CBCT). The model was analyzed by the Ansys software. The model fixation occurred at the root of the abutment teeth and an axial load of 300 N was applied on the occlusal surface of the pontic. The highest stress value was observed for the Variolink 0.4 group (1.76 × 106 Pa), while the lowest was noted for the Panavia 0.2 group (1.07 × 106 Pa). Furthermore, the highest total deformation value was found for the Variolink 0.2 group (3.36 × 10−4 m), while the lowest was observed for the Panavia 0.4 group (2.33 × 10−4 m). By means of this FEA, 0.2 mm layer Panavia F2.0 seemed to exhibit a more favorable stress distribution when used for cementation of posterior zirconium-dioxide-based RBFPD. However, both studied materials possessed clinically acceptable properties.
There is a scant literature on the accuracy of dental photographs captured by Digital Single-Lens Reflex (DSLR) and smartphone cameras. The aim was to compare linear measurements of plaster models photographed with DSLR and smartphone’s camera with digital models. Thirty maxillary casts were prepared. Vertical and horizontal reference lines were marked on each tooth, with exception to molars. Then, models were scanned with the TRIOS 3 Basic intraoral dental scanner (control). Six photographs were captured for each model: one using DSLR camera (Canon EOS 700D) and five with smartphone (iPhone X) (distance range 16-32 cm). Teeth heights and widths were measured on scans and photographs. The following conclusions could be drawn: (1) the measurements of teeth by means of DSLR and smartphone cameras (at distances of at least 24 cm) and scan did not differ. (2) The measurements of anterior teeth by means of DSLR and smartphone cameras (at all distances tested) and scan exhibited no difference. For documentational purposes, the distortion is negligeable, and both camera devices can be applied. Dentists can rely on DSLR and smartphone cameras (at distances of at least 24 cm) for smile designs providing comparable and reliable linear measurements.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.