The European Society of Gastrointestinal Endoscopy and United European Gastroenterology present a short list of key performance measures for lower gastrointestinal endoscopy. We recommend that endoscopy services across Europe adopt the following seven key performance measures for lower gastrointestinal endoscopy for measurement and evaluation in daily practice at a center and endoscopist level:
1 Rate of adequate bowel preparation (minimum standard 90?%); 2?Cecal intubation rate (minimum standard 90?%); 3 Adenoma detection rate (minimum standard 25?%); 4 Appropriate polypectomy technique (minimum standard 80?%); 5 Complication rate (minimum standard not set); 6 Patient experience (minimum standard not set); 7 Appropriate post-polypectomy surveillance recommendations (minimum standard not set).
Other identified performance measures have been listed as less relevant based on an assessment of their importance, scientific acceptability, feasibility, usability, and comparison to competing measures.
Main RecommendationsThe following recommendations for post-polypectomy colonoscopic surveillance apply to all patients who had one or more polyps that were completely removed during a high quality baseline colonoscopy.
1 ESGE recommends that patients with complete removal of 1 – 4 < 10 mm adenomas with low grade dysplasia, irrespective of villous components, or any serrated polyp < 10 mm without dysplasia, do not require endoscopic surveillance and should be returned to screening.Strong recommendation, moderate quality evidence.If organized screening is not available, repetition of colonoscopy 10 years after the index procedure is recommended.Strong recommendation, moderate quality evidence.
2 ESGE recommends surveillance colonoscopy after 3 years for patients with complete removal of at least 1 adenoma ≥ 10 mm or with high grade dysplasia, or ≥ 5 adenomas, or any serrated polyp ≥ 10 mm or with dysplasia. Strong recommendation, moderate quality evidence.
3 ESGE recommends a 3 – 6-month early repeat colonoscopy following piecemeal endoscopic resection of polyps ≥ 20 mm.Strong recommendation, moderate quality evidence. A first surveillance colonoscopy 12 months after the repeat colonoscopy is recommended to detect late recurrence.Strong recommendation, high quality evidence.
4 If no polyps requiring surveillance are detected at the first surveillance colonoscopy, ESGE suggests to perform a second surveillance colonoscopy after 5 years. Weak recommendation, low quality evidence.After that, if no polyps requiring surveillance are detected, patients can be returned to screening.
5 ESGE suggests that, if polyps requiring surveillance are detected at first or subsequent surveillance examinations, surveillance colonoscopy may be performed at 3 years. Weak recommendation, low quality evidence.A flowchart showing the recommended surveillance intervals is provided (Fig. 1).
The European Society of Gastrointestinal Endoscopy and United European Gastroenterology present a short list of key performance measures for lower gastrointestinal endoscopy. We recommend that endoscopy services across Europe adopt the following seven key performance measures for lower gastrointestinal endoscopy for measurement and evaluation in daily practice at a center and endoscopist level: rate of adequate bowel preparation (minimum standard 90%); cecal intubation rate (minimum standard 90%); adenoma detection rate (minimum standard 25%); appropriate polypectomy technique (minimum standard 80%); complication rate (minimum standard not set); patient experience (minimum standard not set); appropriate post-polypectomy surveillance recommendations (minimum standard not set). Other identified performance measures have been listed as less relevant based on an assessment of their importance, scientific acceptability, feasibility, usability, and comparison to competing measures.
Endoscopic resection of large polyps appeared to be an extremely effective and safe intervention. However, an adequate endoscopic surveillance is necessary for its long-term efficacy.
Fasting instructions prior to UGI endoscopy Minimum 7-minute procedure time for first diagnostic UGI endoscopy and follow-up of gastric intestinal metaplasia Documentation of procedure duration Minimum 1-minute inspection time per cm circumferential Barrett's epithelium Accurate photodocumentation of anatomical landmarks and abnormal findings Use of Lugol chromoendoscopy in patients with a curatively treated ENT or lung cancer to exclude a second primary esophageal cancer Accurate application of standardized disease-related terminology Application of validated biopsy protocol to detect gastric intestinal metaplasia (MAPS guidelines) Application of Seattle protocol in Barrett's surveillance Prospective registration of Barrett's patients Accurate registration of complications after therapeutic UGI endoscopy UGI, upper gastrointestinal; ENT, ear, nose, and throat; MAPS, management of patients with precancerous conditions and lesions of the stomach.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.