Peritoneal dialysis (PD) uses the peritoneal membrane for dialysis. The peritoneal membrane is a thin layer of tissue that lines the abdomen. The lining is used as a filter to help remove extra fluid and poisonous waste from the blood. Everybody is unique. What is normal for one person’s membrane may be very different from another person’s. The kidney care team wants to provide each person with the best dialysis prescription for them and to do this they must evaluate the person’s peritoneal lining. Sometimes dialysis treatment itself can cause the membrane to change after some years. This means more assessments (evaluations) will be needed to determine whether the person’s peritoneal membrane has changed. Changes in the membrane may require changes to the dialysis prescription. This is needed to achieve the best dialysis outcomes. A key tool for these assessments is the peritoneal equilibration test (PET). It is a simple, standardized and reproducible tool. This tool is used to measure the peritoneal function soon after the start of dialysis. The goal is to understand how well the peritoneal membrane works at the start of dialysis. Later on in treatment, the PET helps to monitor changes in peritoneal function. If there are changes between assessments causing problems, the PET data may explain the cause of the dysfunction. This may be used to change the dialysis prescription to achieve the best outcomes. The most common problem with the peritoneal membrane occurs when fluid is not removed as well as it should be. This happens when toxins (poisons) in the blood cross the membrane more quickly than they should. This is referred to as a fast peritoneal solute transfer rate (PSTR). Since more efficient fluid removal is associated with better outcomes, developing a personal PD prescription based on the person’s PSTR is critically important. A less common problem happens when the membrane fails to work properly (also called membrane dysfunction) because the peritoneal membrane is less efficient, either at the start of treatment or developing after some years. If membrane dysfunction gets worse over time, then this is associated with progressive damage, scarring and thickening of the membrane. This problem can be identified through another change of the PET. It is called reduced ‘sodium dip’. Membrane dysfunction of this type is more difficult to treat and has many implications for the individual. If the damage is major, the person may need to stop PD. They would need to begin haemodialysis treatment (also spelled hemodialysis). This is a very important and emotional decision for individuals with kidney failure. Any decision that involves stopping PD therapy or transitioning to haemodialysis therapy should be made jointly between the clinical team, the person on dialysis and a caregiver, if requested. Although evidence is lacking about how often tests should be performed to determine peritoneal function, it seems reasonable to repeat them whenever there is difficulty in removing the amount of fluid necessary for maintaining the health and well-being of the individual. Whether routine evaluation of membrane function is associated with better outcomes has not been studied. Further research is needed to answer this important question as national policies in many parts of the world and the COVID-19 has placed a greater emphasis and new incentives encouraging the greater adoption of home dialysis therapies, especially PD. For Chinese and Spanish Translation of the Lay Summary, see Online Supplement Appendix 1. Guideline 1: A pathophysiological taxonomy: A pathophysiological classification of membrane dysfunction, which provides mechanistic links to functional characteristics, should be used when prescribing individualized dialysis or when planning modality transfer (e.g. to automated peritoneal dialysis (PD) or haemodialysis) in the context of shared and informed decision-making with the person on PD, taking individual circumstances and treatment goals into account. (practice point) Guideline 2a: Identification of fast peritoneal solute transfer rate (PSTR): It is recommended that the PSTR is determined from a 4-h peritoneal equilibration test (PET), using either 2.5%/2.27% or 4.25%/3.86% dextrose/glucose concentration and creatinine as the index solute. (practice point) This should be done early in the course dialysis treatment (between 6 weeks and 12 weeks) (GRADE 1A) and subsequently when clinically indicated. (practice point) Guideline 2b: Clinical implications and mitigation of fast solute transfer: A faster PSTR is associated with lower survival on PD. (GRADE 1A) This risk is in part due to the lower ultrafiltration (UF) and increased net fluid reabsorption that occurs when the PSTR is above the average value. The resulting lower net UF can be avoided by shortening glucose-based exchanges, using a polyglucose solution (icodextrin), and/or prescribing higher glucose concentrations. (GRADE 1A) Compared to glucose, use of icodextrin can translate into improved fluid status and fewer episodes of fluid overload. (GRADE 1A) Use of automated PD and icodextrin may mitigate the mortality risk associated with fast PSTR. (practice point) Guideline 3: Recognizing low UF capacity: This is easy to measure and a valuable screening test. Insufficient UF should be suspected when either (a) the net UF from a 4-h PET is <400 ml (3.86% glucose/4.25% dextrose) or <100 ml (2.27% glucose /2.5% dextrose), (GRADE 1B) and/or (b) the daily UF is insufficient to maintain adequate fluid status. (practice point) Besides membrane dysfunction, low UF capacity can also result from mechanical problems, leaks or increased fluid absorption across the peritoneal membrane not explained by fast PSTR. Guideline 4a: Diagnosing intrinsic membrane dysfunction (manifesting as low osmotic conductance to glucose) as a cause of UF insufficiency: When insufficient UF is suspected, the 4-h PET should be supplemented by measurement of the sodium dip at 1 h using a 3.86% glucose/4.25% dextrose exchange for diagnostic purposes. A sodium dip ≤5 mmol/L and/or a sodium sieving ratio ≤0.03 at 1 h indicates UF insufficiency. (GRADE 2B) Guideline 4b: Clinical implications of intrinsic membrane dysfunction (de novo or acquired): in the absence of residual kidney function, this is likely to necessitate the use of hypertonic glucose exchanges and possible transfer to haemodialysis. Acquired membrane injury, especially in the context of prolonged time on treatment, should prompt discussions about the risk of encapsulating peritoneal sclerosis. (practice point) Guideline 5: Additional membrane function tests: measures of peritoneal protein loss, intraperitoneal pressure and more complex tests that estimate osmotic conductance and ‘lymphatic’ reabsorption are not recommended for routine clinical practice but remain valuable research methods. (practice point) Guideline 6: Socioeconomic considerations: When resource constraints prevent the use of routine tests, consideration of membrane function should still be part of the clinical management and may be inferred from the daily UF in response to the prescription. (practice point)
IntroductionIn the current study, an extended 3-pore model (TPM) is presented and applied to the problem of optimizing automated peritoneal dialysis (APD) with regard to osmotic water transport (UF), small/middle-molecule clearance, and glucose absorption.MethodsSimulations were performed for either intermittent APD (IPD) or tidal APD (TPD). IPD was simulated for fill and drain volumes of 2 L, whereas TPD was simulated using a tidal volume of 0.5 L, 1 L, or 1.5 L with full drains and subsequent fills (2 L) occurring after every fifth dwell. A total of 25 cycles for a large number of different dialysate flow rates (DFR) were simulated using 3 different glucose concentrations (1.36%, 2.27%, and 3.86%) and 3 different peritoneal transport types: slow (peritoneal equilibrium test D/Pcrea < 0.6), fast (peritoneal equilibrium test D/Pcrea > 0.8), and average. Solute clearance and UF were simulated to occur during the entire dwell, including both fill and drain periods.ResultsIt is demonstrated that DFRs exceeding ∼ 3 L/h are of little benefit both for UF and small-solute transport, whereas middle-molecule clearance is enhanced at higher DFRs. The simulations predict that large reductions (> 20%) in glucose absorption are possible by using moderately higher DFRs than a standard 6 × 2 L prescription and by using shorter optimized “bi-modal” APD regimens that alternate between a glucose-free solution and a glucose-containing solution.DiscussionReductions in glucose absorption appear to be significant with the proposed regimens for APD; however, further research is needed to assess the feasibility and safety of these regimens.
In the present study, an extended two-pore theory is presented where the porous pathways are continuously distributed according to small- and large-pore mean radii and SDs. Experimental glomerular sieving data for Ficoll were analyzed using the model. In addition, several theoretical findings are presented along with analytic solutions to many of the equations used in distributed pore modeling. The results of the data analysis revealed a small-pore population in the glomerular capillary wall with a mean radius of 36.6 Å having a wide arithmetic SD of ∼5 Å and a large-pore radius of 98.6 Å with an even wider SD of ∼44 Å. The small-pore radius obtained in the analysis was close to that of human serum albumin (35.5 Å). By reanalyzing the data and setting the distribution spread of the model constant, we discovered that a narrow distribution is compensated by an increased mean pore radius and a decreased pore area-to-diffusion length ratio. The wide distribution of pore sizes obtained in the present analysis, even when considering electrostatic hindrance due to the negatively charged barrier, is inconsistent with the high selectivity to proteins typically characterizing the glomerular filtration barrier. We therefore hypothesize that a large portion of the variance in the distribution of pore sizes obtained is due to the molecular "flexibility" of Ficoll, implying that the true variance of the pore system is lower than that obtained using flexible probes. This would also, in part, explain the commonly noted discrepancy between the pore area-to-diffusion length ratio and the filtration coefficient.
Osmosis drives transcapillary ultrafiltration and water removal in patients treated with peritoneal dialysis. Crystalloid osmosis, typically induced by glucose, relies on dialysate tonicity and occurs through endothelial aquaporin-1 water channels and interendothelial clefts. In contrast, the mechanisms mediating water flow driven by colloidal agents, such as icodextrin, and combinations of osmotic agents have not been evaluated. We used experimental models of peritoneal dialysis in mouse and biophysical studies combined with mathematical modeling to evaluate the mechanisms of colloid versus crystalloid osmosis across the peritoneal membrane and to investigate the pathways mediating water flow generated by the glucose polymer icodextrin. modeling and studies showed that deletion of aquaporin-1 did not influence osmotic water transport induced by icodextrin but did affect that induced by crystalloid agents. Water flow induced by icodextrin was dependent upon the presence of large, colloidal fractions, with a reflection coefficient close to unity, a low diffusion capacity, and a minimal effect on dialysate osmolality. Combining crystalloid and colloid osmotic agents in the same dialysis solution strikingly enhanced water and sodium transport across the peritoneal membrane, improving ultrafiltration efficiency over that obtained with either type of agent alone. These data cast light on the molecular mechanisms involved in colloid versus crystalloid osmosis and characterize novel osmotic agents. Dialysis solutions combining crystalloid and colloid particles may help restore fluid balance in patients treated with peritoneal dialysis.
The actions of systemic angiotensin II (ANG II) infusions on glomerular permeability were investigated in vivo. In anesthetized Wistar rats (250-280 g), the left ureter was cannulated for urine collection, while simultaneously blood access was achieved. Rats were continuously infused intravenously with either of four doses of ANG II ranging from 16 ng·kg(-1)·min(-1) (Lo-ANG II) to 1.82 μg·kg(-1)·min(-1) (Hi-ANG II), and in separate experiments with aldosterone (Aldo; 0.22 mg·kg(-1)·min(-1)), or with the calcium channel blocker nimodipine, or with the Aldo antagonist spironolactone together with a high ANG II dose (910 ng·kg(-1)·min(-1); Hi-Int-ANG II), respectively, and with polydisperse FITC-Ficoll-70/400 (molecular radius 10-80 Å) and (51)Cr-EDTA. Plasma and urine samples were taken at 5, 15, 30, 60, and 120 min and analyzed by high performance size-exclusion chromatography for determination of glomerular sieving coefficients (θ) to Ficoll. Mean arterial pressure (MAP) and glomerular filtration rate (GFR) were also assessed. For ANG II, there was a rapid, marked, partly reversible increase in glomerular permeability (θ) for Ficoll molecules >34 Å in radius, peaking at 5-15 min, which was completely abrogated by the ANG II blocker candesartan but not affected by spironolactone at 15 and 30 min. For Aldo, the response was similar to that found for the lowest dose of ANG II infused. For the two highest ANG II doses given (Hi-Int-ANG II and Hi-ANG II), GFR decreased transiently, concomitant with marked, sustained increases in MAP. Nimodipine completely blocked all hemodynamic ANG II actions, whereas the glomerular permeability response remained unchanged. Thus ANG II directly increased glomerular permeability independently of its hemodynamic actions and largely independently of the concomitant Aldo response. The ANG II-induced increases in glomerular permeability were, according to a two-pore and a log-normal distributed pore model, compatible with an increased number of "large pores" in the glomerular filter, and, to some extent, an increase in the dispersity of the small-pore radius.
Introduction: Unwanted glucose absorption during peritoneal dialysis (PD) remains a clinical challenge, especially in diabetic patients. Recent experimental data indicated that inhibitors of the sodium and glucose co-transporter (SGLT)-2 could act to reduce glucose uptake during PD, which raises the question of whether glucose absorption may also occur via intracellular or trans-cellular pathways. Methods: We performed PD in anesthetized Sprague-Dawley rats using a fill volume of 20 mL with either 1.5% glucose fluid or 4.25% glucose fluid for 120 min dwell time to evaluate the effects of SGLT2 inhibition by empagliflozin on peritoneal water and solute transport. To assess the diffusion capacity of glucose, we developed a modified equation to measure small solute diffusion capacity, taking convective- and free water transport into account. Results: SGLT2 inhibition markedly increased the urinary excretion of glucose and lowered plasma glucose after PD compared to sham groups. Glucose absorption for 1.5% glucose was 165 mg 95% CI (145–178) in sham animals and 157 mg 95% CI (137–172) for empagliflozin-treated animals. For 4.25% glucose, absorption of glucose was 474 mg 95% CI (425–494) and 472 mg 95% CI (420–506) for sham and empagliflozin groups, respectively. No significant changes in the transport of sodium or water across the peritoneal barrier could be detected. Conclusion: We could not confirm recent findings that SGLT2 inhibition reduced glucose absorption and increased osmotic water transport during experimental PD.
This paper describes the design, development, and initial application of a sensor-actuated network for sensing and sampling microbial communities in aquatic ecosystems. The network consists of ten stationary buoys and one mobile robotic boat for real-time, in situ measurements and analysis of chemical and physical factors governing the abundance and dynamics of microorganisms at biologically relevant spatiotemporal scales. The goal of the network is to obtain high-resolution information on the spatial and temporal distributions of plankton assemblages and concomitant environmental parameters in aquatic environments using the in situ presence afforded by the network and to make possible network-enabled robotic sampling of hydrographic features of interest. This work constitutes advances in (1) real-time observing in aquatic ecosystems and (2) sensor actuated sampling for biological analysis.
Recent developments in the field of the autonomous underwater vehicles allow the wide usage of these platforms as part of scientific experiments, monitoring campaigns and more. The vehicles are often equipped with sensors measuring temperature, conductivity, chlorophyll a fluorescence (Chl a), colored dissolved organic matter (CDOM) fluorescence, phycoerithrin (PE) fluorescence and spectral volume scattering function at 117 degrees, providing users with high resolution, real time data. However, calibration of these instruments can be problematic. Most in situ calibrations are performed by deploying complementary instrument packages or water samplers in the proximity of the glider. Laboratory calibrations of the mounted sensors are difficult due to the placement of the instruments within the body of the vehicle. For the laboratory calibrations of the Slocum glider instruments we developed a small calibration chamber where we can perform precise calibrations of the optical instruments aboard our glider, as well as sensors from other deployment platforms. These procedures enable us to obtain pre- and post-deployment calibrations for optical fluorescence instruments, which may differ due to the biofouling and other physical damage that can occur during long-term glider deployments. We found that biofouling caused significant changes in the calibration scaling factors of fluorescent sensors, suggesting the need for consistent and repetitive calibrations for gliders as proposed in this paper.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.