Carbon monoxide (CO) is a colourless and odourless poisonous gas formed from the incomplete combustion of substances containing carbon. In the United Kingdom, over 22 million homes have mains or liquefied petroleum gas and consequently there is particular concern regarding potential CO poisoning resulting from malfunctioning domestic gas appliances. Although the number of reported cases of CO poisoning in the United Kingdom is relatively small, there is a high probability of misdiagnosis of the condition due to the ambiguous clinical symptoms of CO poisoning; incidence may therefore be much higher than currently reported. This review discusses the current knowledge on human health and toxicological effects following exposure to CO, focusing particularly on the public health impacts associated with gas appliances in UK homes. In determining the possibility of an underlying threat, the biological plausibility of misdiagnosis, in combination with reported cases, is discussed. The implication of misdiagnosis for public health treatment is also briefly summarised.
When the BWR at Duane Arnold went on-line, it was rated at 565.7 MWe. Some time ago, due to operational and other problems it was determined that it would be economical to isolate the HP reheaters from service in the double-stage two Moisture Separator Reheaters (MSRs). Duane Arnold is now undergoing an extensive and lengthy life-extension and uprating program, targeted at 16 percent involving many components. After a detailed study involving several alternative approaches to upgrading the MSRs in conjunction with a new, larger HP turbine, they have now been completely redesigned and reconstructed using essentially the original configuration — 2-pass LP and HP reheaters with chevron moisture separator sections, but using advanced technology throughout and in conjunction with the optimization of the uprated turbine generator. In order to minimize component installation time and reduce personnel radiation exposure, the modern Moisture Separation (M.S.) components were “modularized” — installed as four completely preassembled M.S. sections replacing the need for the in-shell installation of multiple small components. This paper covers the many alternative choices considered and details all elements and phases of the final MSR upgrade design and installation process selected. The installation of a new main turbine, oversized in anticipation of an increase in thermal power, was expected to result in a decrease of about 10 MWe due to throttling losses across the turbine control valves. The refurbished MSR with restored second stage reheat was expected to just offset this loss. Post installation testing showed a gain of 4 MWe beyond the offset of the turbine control valve throttling losses. As a result, the net gain over previous operation is therefore 4 MWe even though the new MSR is responsible for gain of about 14 MWe.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.