Introduction Sedative and analgesic drugs are frequently used in critically ill patients. Their overuse may prolong mechanical ventilation and length of stay in the intensive care unit. Guidelines recommend use of sedation protocols that include sedation scores and trials of sedation cessation to minimize drug use. We evaluated processed electroencephalography (response and state entropy and bispectral index) as an adjunct to monitoring effects of commonly used sedative and analgesic drugs and intratracheal suctioning. Methods Electrodes for monitoring bispectral index and entropy were placed on the foreheads of 44 critically ill patients requiring mechanical ventilation and who previously had no brain dysfunction. Sedation was targeted individually using the Ramsay Sedation Scale, recorded every 2 hours or more frequently. Use of and indications for sedative and analgesic drugs and intratracheal suctioning were recorded manually and using a camera. At the end of the study, processed electroencephalographical and haemodynamic variables collected before and after each drug application and tracheal suctioning were analyzed. Ramsay score was used for comparison with processed electroencephalography when assessed within 15 minutes of an intervention. Results The indications for boli of sedative drugs exhibited statistically significant, albeit clinically irrelevant, differences in terms of their association with processed electroencephalographical parameters. Electroencephalographical variables decreased significantly after bolus, but a specific pattern in electroencephalographical variables before drug administration was not identified. The same was true for opiate administration. At both 30 minutes and 2 minutes before intratracheal suctioning, there was no difference in electroencephalographical or clinical signs in patients who had or had not received drugs 10 minutes before suctioning. Among patients who received drugs, electroencephalographical parameters returned to baseline more rapidly. In those cases in which Ramsay score was assessed before the event, processed electroencephalography exhibited high variation. Conclusions Unpleasant or painful stimuli and sedative and analgesic drugs are associated with significant changes in processed electroencephalographical parameters. However, clinical indications for drug administration were not reflected by these electroencephalographical parameters, and barely by sedation level before drug administration or tracheal suction. This precludes incorporation of entropy and bispectral index as target variables for sedation and analgesia protocols in critically ill patients.
BackgroundMidazolam is commonly used as a pre-anesthesia anxiolytic. It`s elimination may not be fast enough for short procedures. In orally premedicated patients we obtained midazolam plasma concentrations at the end of surgical procedures and compared those to concentrations at anesthesia induction.MethodsThe study was conducted prospectively with consent of the local ethics committee (Ethikkomission Kanton Thurgau, Switzerland) and carried out with written informed consent of each patient. Female patients aged 20 to 60 years undergoing elective procedures with general anesthesia were included, and were divided in two groups according to the planned surgical time: group S (<30 min) and group L (90–120 min), respectively. All patients received 7.5 mg Midazolam po as premedication. Blood samples were drawn at anesthesia induction, and at the end of surgery. Data were compared with t-test (independent samples; significance level p <0.05).ResultsTwenty-five patients per group were included. Four patients were excluded from analysis, since midazolam was not detectable in any samples. Time of premedication to the 1st blood sample was not statistically different between groups, neither were Midazolam plasma levels at this time point (p = 0.94). None of the patients from group L (n = 24), but five patients in group S (n = 22) did have a higher plasma level of Midazolam at the end of the case compared to the beginning.ConclusionsThe elimination half-life of oral Midazolam can lead to higher plasma levels at the end of a short procedure compared to those at induction of anesthesia.Trial registrationGerman Clinical Trials Register (Deutsches Register Klinischer Studien), DRKS00005429; date of registration 3rd January 2014
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.