The technique of using a "live annulus" for data collection analysis during frac pack sand control completions has evolved quite extensively over the past few years. Field case studies have revealed several anomalies in this data collection and analysis. The following discussion covers more than 100 wells completed in the Gulf of Mexico using mini frac data analysis on both the workstring and "live annulus" data and their relationship to the bottomhole gauge data. The ability to incorporate this "live annulus" data has been facilitated by downhole tool development. The use of "live annulus" data has been viewed by many as being the single most important factor in the successful interpretation of pressure analysis during frac pack operations. Certainly, the elimination of friction in trying to interpret real time data enhanced the ability to make "on-the-fly" decisions. Having a "live annulus" also may help in overcoming some of the water hammer problems in rapid closure situations. However, caution must be used in relying on "live annulus" data. A close look at this summary of data completed in the Gulf of Mexico highlights the need for this caution and questions the degree of it s use. Introduction In the last decade, the evolution of frac packs in high permeability environments have been influenced by lessons learned from data analysis of live surface data and enhanced by bottomhole gauge data. Numerous techniques for analyzing data and designing treatments such as those by Nolte1 and Smith2 have been put into practice for success in frac pack sand control completions. "Live annulus" data analysis has greatly influenced the decision making process for frac pack sand control completions in the Gulf of Mexico. One aspect of "live annulus" data is that during pumping operations, the friction factor for fluids being pumped down a workstring is left out and a more representative profile of bottomhole pressure response is seen less the hydrostatic pressure from the static fluid in the annulus. This is possible from the developments of downhole frac pack packers in the industry that enable the annulus and workstring environments to be in communication with each other simultaneously. As seen in Figure 1, while pumping a Step-Rate-Test, the annulus data is much easier to use for the pressure analysis than the pressure data from the workstring. This is because the dynamically changing friction pressure effects of the fluids in the workstring would be hard to model. Again, the annulus data is simply the bottomhole pressure response less some hydrostatic pressure and as seen in Figure 2, closely follows the recorded bottomhole gauge data. There are instances where data analyzed during mini frac analysis will be performed with "live annulus" data in order to eliminate the early time water hammer effect, that is present with workstring data, hindering the analysis effort in determining closure pressure. Figure 3 is an example of the water hammer effect on workstring data and how it relates to the annulus and bottomhole gauge data. In some situations, closure can happen during this time period due to high leakoff and interpretation of the workstring data can be very difficult. However, caution must be used in deciding that annulus data interpretation will be used under these circumstances. The water hammer effect sometimes can also be seen as illustrated in Figure 4 with "live annulus" data. Figure 5 is an example of how specific tool designs dictate that the annulus data will closely follow the bottomhole gauge data while pumping and when pumping is stopped, the annulus data does not continue to follow the same profile as the bottomhole gauge data. This happens because the specific tool design does not allow for a full flow of pressure in the reverse direction, thus creating a "check valve" or choke affect. Figure 6 is an example of a case where the "live annulus" pressure falloff data did not match that seen by the workstring data or the bottomhole gauge data. Herein lies the dilemma of which data do you use at the time of treatment execution and which is most accurate or meaningful.
TX 75083-3836, U.S.A., fax 01-972-952-9435. AbstractThe technique of using a "live annulus" for data collection analysis during frac pack sand control completions has evolved quite extensively over the past few years. Field case studies have revealed several anomalies in this data collection and analysis.The following discussion covers more than 100 wells completed in the Gulf of Mexico using mini frac data analysis on both the workstring and "live annulus" data and their relationship to the bottomhole gauge data. The ability to incorporate this "live annulus" data has been facilitated by downhole tool development.The use of "live annulus" data has been viewed by many as being the single most important factor in the successful interpretation of pressure analysis during frac pack operations. Certainly, the elimination of friction in trying to interpret real time data enhanced the ability to make "on-the-fly" decisions. Having a "live annulus" also may help in overcoming some of the water hammer problems in rapid closure situations. However, caution must be used in relying on "live annulus" data. A close look at this summary of data completed in the Gulf of Mexico highlights the need for this caution and questions the degree of it's use.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.