Radiotherapy is an important treatment modality against cancer resulting in apoptosis and inhibition of cell growth. Survivin is an important cancer biomarker conferring to tumour cells increased survival potential by inhibiting apoptosis. In the present study, we investigated the implication of breast cancer cells features, as hormone receptors and p53 status, in the radio-resistance of breast cancer cells and in the regulation of survivin’s expression by nuclear factor (NF)-κB and c-myc. Six breast cancer cell lines Michigan Cancer Foundation (MCF-7), MCF-7/Human Epidermal Growth Factor Receptor (HER)2, M. D. Anderson – Metastatic Breast (MDA-MB-231), SK-BR-3, BT-474 and Human Breast Lactating (HBL-100) were irradiated and cell viability as well as cell cycle distribution were evaluated by 3-(4,5-Dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) assay and flow cytometry, respectively. Survivin mRNA and protein levels were evaluated by real time PCR and Western blot analysis. Survivin and HER2 gene knockdown was performed with siRNA technology and investigation of transcription factors binding to survivin and c-myc gene promoters was assessed by chromatin immunoprecipitation. Student’s t-test and F-statistics were used for statistical evaluation. Our results demonstrated that only HER2+ breast cancer cells up-regulated survivin upon irradiation, whereas HER2 knockdown in HER2+ cells led to survivin’s down-regulation. Survivin and especially HER2 knockdown abolished the observed G2/M cell cycle checkpoint and reduced the radio-resistance of HER2 overexpressing breast cancer cells. Additionally, HER2 was found to regulate survivin’s expression through NF-κB and c-myc transcription factors. This study revealed the significance of HER2 in the radio-resistance of HER2+ breast cancer cells through induction of transcription factors NF-κB and c-myc, leading to activation of survivin, a downstream target oncogene preventing apoptosis.
Purpose. To determine whether in vivo proton magnetic resonance spectroscopy at 3T can provide accurate breast lesion characterization, and to determine the effect of gadolinium on the resonance of tCho. Methods. Twenty-four positive-mammogram patients were examined on a 3T MR scanner. 1H-MRS was performed before and after gadolinium administration. tCho peak was qualitatively evaluated before and after contrast injection. Results. Fourteen out of 27 lesions proved to be malignant after histopathological diagnosis. Using 1H-MRS, before contrast injection, 6/14 confirmed malignancies and 11/13 benign lesions were correctly classified; while, after contrast injection, 11/14 confirmed malignancies and 12/13 benign processes were correctly classified. Post gadolinium 1H-MRS proved useful in picking up tCho signal, improving the overall accuracy, sensitivity, and specificity by 35%, 83%, and 9%, respectively. Conclusion. 1H-MRS overall accuracy, sensitivity, and specificity in detecting breast lesion's malignancy were increased after gadolinium administration. It is prudent to perform 1H-MRS before contrast injection in large breast lesions to avoid choline underestimation. In cases of small or non-mass lesions, it is recommended to perform 1H-MRS after contrast injection for better voxel prescription to enable a reliable preoperative diagnosis.
FASMA is a prototype CDSS, which integrates complex quantitative MR data for brain tumor characterization. FASMA was developed as a diagnostic assistant that provides fast analysis, representation and classification for a set of MR parameters. This software may serve as a teaching tool on advanced MRI techniques, as it incorporates additional information regarding typical tumor characteristics derived from the literature.
A correlation between TA and hTERT mRNA expression and a radiation induced cell cycle dependent modification of hTERT mRNA expression was established for the first 24 h post-irradiation.
Structural radiation protection for diagnostic X-ray facilities is most commonly performed following the recommendations of the National Council on Radiation Protection and Measurements Report No. 49. A number of analytical methods have already been developed to improve the design of these facilities. Specifically, these methods reassess shielding calculations in X-ray areas with respect to the methodology of the calculation of the barrier thickness and the number of sources considered in the area. Thus, they generate an overall solution for the cases met at the medical radiation structural design. This paper presents an extension of an existing method for calculating shielding requirements, for multiple X-ray tubes in a room operated at various beam qualities. The methodology computes the required shielding thickness such that the exposure behind it stays below a desired value. The presented method eliminates the overestimation of added shielding thickness which may occur using the other methods already mentioned. A user-friendly windows-based program has also been developed to assist shielding computations.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.