In interventional cardiology, a wide variation in patient dose for the same type of procedure has been recognised by different studies. Variation is almost due to procedure complexity, equipment performance, procedure protocol and operator skill. The SENTINEL consortium has performed a survey in nine european centres collecting information on near 2000 procedures, and a new set of reference levels (RLs) for coronary angiography and angioplasty and diagnostic electrophysiology has been assessed for air kerma-area product: 45, 85 and 35 Gy cm2, effective dose: 8, 15 and 6 mSv, cumulative dose at interventional reference point: 650 and 1500 mGy, fluoroscopy time: 6.5, 15.5 and 21 min and cine frames: 700 and 1000 images, respectively. Because equipment performance and set-up are the factors contributing to patient dose variability, entrance surface air kerma for fluoroscopy, 13 mGy min(-1), and image acquisition, 0.10 mGy per frame, have also been proposed in the set of RLs.
Patient doses for a few common fluoroscopy-guided procedures in interventional radiology (IR) (excluding cardiology) were collected from a few radiological departments in 13 European countries. The major aim was to evaluate patient doses for the basis of the reference levels. In total, data for 20 procedures for about 1300 patients were collected. There were many-fold variations in the number of IR equipment and procedures per population, in the entrance dose rates, and in the patient dose data (total dose area product or DAP, fluoroscopy time and number of frames). There was no clear correlation between the total DAP and entrance dose rate, or between the total DAP and fluoroscopy time, indicating that a number of parameters affect the differences. Because of the limited number of patients, preliminary reference levels were proposed only for a few procedures. There is a need to improve the optimisation of IR procedures and their definitions and grouping, in order to account for their different complexities.
In interventional cardiac procedures, staff operates near the patient in a non-uniformly scattered radiation field. Consequently, workers may receive, over a period, relatively high radiation doses. The measurement of individual doses to personnel becomes critical due to the use of protective devices and, as a consequence of the large number of methods proposed to assess the effective dose, great variability in monitoring programmes is expected among European countries. SENTINEL consortium has conducted a survey on staff dosimetry methods and on the level of staff exposure in 12 European cardiac centres demonstrating the urgent need to harmonise dosimetry methods. From the dosimetry survey, constraint annual effective dose of 1.4 mSv and Hp(0.07) over the protective apron of 14 mSv are proposed for the optimisation the exposure the most-exposed operator.
An internal audit has been performed to evaluate the patient radiation dose in the clinical use of X-ray cardiac flat panel detector (FPD) systems. Fluoroscopy and image acquisition (cine mode) programs are optimised for low-dose settings. The diagnostic and therapeutic interventional cardiac procedures are performed at 6 pulse s(-1) for fluoroscopy and 15 frames s(-1) for image acquisition. The FPD entrance dose is configured for 29 nGy pulse(-1) in the fluoroscopy mode and 0.10 microGy frame(-1) in the cine mode. From the data collected, the following local reference levels for coronary angiography and angioplasty have been obtained: kerma-area products 23 and 44 Gy cm(2), cumulative doses 376 and 776 mGy, fluoroscopy times 5 and 15.5 min and cine images 617 and 1163 images.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.