WOMAC and MOS SF-36 detect significant and clinically meaningful changes in outcome after hip and knee replacement. WOMAC requires a smaller sample size and is more responsive in the short term. For a follow-up longer than 6 months MOS SF-36 provides additional information. The improvement in outcomes following hip joint surgery were significantly greater than those following knee surgery.
The discriminatory potential to classify subjects with or without vertebral fractures was tested cross-sectionally with different methods for the measurement of bone status in a population-based sample of postmenopausal women. Quantitative ultrasound (QUS) measurement at the calcaneus (Lunar Achilles, Hologic Sahara), the proximal phalanges (Igea Bone Profiler), and measurement of bone mineral density (BMD) with dual-energy X-ray absorptiometry (DXA; Lunar Expert) at several anatomic sites was performed in 500 postmenopausal women (aged 65-75 years) randomly selected from the population. In addition, 50 young female subjects (20 -40 years old) had QUS measurements and served as controls to express QUS results as T-score values. Radiographs of the lumbar and thoracic spine were performed in the elderly women. Two independent radiologists reviewed the X-rays for the presence of vertebral fractures. Of 486 eligible study participants, no fracture was seen in 396 participants. Single vertebral fractures were observed in 71 subjects; 19 individuals presented multiple fractures. The overall prevalence of vertebral fractures was 18.5%. Participants without vertebral fractures were compared with subjects with vertebral fractures. Normal statistical distributions were found for all bone measurement results. Risk of vertebral fracture in subjects with no and multiple vertebral fracture was estimated using age adjusted odds ratios (ORs) for QUS and dual-energy X-ray absorptiometry (DXA) values. Each SD decrease in bone measurement increased the risk of multiple vertebral fracture by 3.0 (95% CI, 1.6 -5.6) for the Achilles stiffness, by 3.8 (95% CI, 1.8 -8.2) for the Sahara QUI, 2.1 (95% CI, 1.3-3.4) for the Bone Profiler amplitude-dependent speed of sound (AD-SOS), and 2.1 (95% CI, 1.2-3.9) and 2.4 (95% CI, 1.3-4.3) for DXA lumbar spine and for DXA total hip, respectively. Results of a discriminant analysis showed sensitivities between 84% and 58% and specificities between 72% and 58% for the respective DXA and QUS parameters. Optimum fracture thresholds for QUS measurements derived from this analysis were calculated also. Optimum T-score threshold values for QUS measurements tended to be higher than those for DXA measurements. However, the performance of QUS measurements is at least comparable with DXA measurements in identifying subjects with multiple vertebral fractures randomly selected from the population.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.