Because of the high prevalence of baffle leaks in adults after atrial switch operations, we propose routine screening with agitated saline contrast, particularly prior to implantation of transvenous pacemaker or defibrillator leads.
SACHER collects multicentre data on adults with CHD. Its structure enables prospective data analysis to assess detailed, lesion-specific outcomes with the aim to finally improve long-term outcomes.
OBJECTIVES
Ventricular assist device (VAD) for systemic right ventricular (RV) failure patients post-atrial switch, for transposition of the great arteries (TGA), and those with congenitally corrected TGA has proven useful to reduce transpulmonary gradient and bridge-to-transplantation. The purpose of this study is to describe our experience of VAD in systemic RV failure and our move towards concomitant tricuspid valve replacement (TVR).
METHODS
This is a single-centre retrospective study of consecutive adult patients receiving HeartWare VAD for systemic RV failure between 2010 and 2019. From 2017, concomitant TVR was performed routinely. Demographic, clinical variables and echocardiographic and haemodynamic measurements pre- and post-VAD implantation were recorded. Complications on support, heart transplantation and survival rates were described.
RESULTS
Eighteen patients underwent VAD implantation. Moderate or severe systemic tricuspid regurgitation was present in 83.3% of patients, and subpulmonic left ventricular impairment in 88.9%. One-year survival was 72.2%. VAD implantation was technically feasible and successful in all but one. Post-VAD, transpulmonary gradient fell from 16 (15–22) to 10 (7–13) mmHg (P = 0.01). Patients with TVR (n = 6) also demonstrated a reduction in mean pulmonary and wedge pressures. Furthermore, subpulmonic left ventricular end-diastolic dimension (44.3 vs 39.6 mm; P = 0.03) and function improved in this group. After 1 year of support, 72.2% of patients were suitable for transplantation.
CONCLUSIONS
VAD is an effective strategy as bridge-to-candidacy and bridge-to-transplantation in patients with end-stage systemic RV failure. Concomitant TVR at the time of implant is associated with better early haemodynamic and echocardiographic results post-VAD.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.