The Messidor database, which contains hundreds of eye fundus images, has been publicly distributed since 2008. It was created by the Messidor project in order to evaluate automatic lesion segmentation and diabetic retinopathy grading methods. Designing, producing and maintaining such a database entails significant costs. By publicly sharing it, one hopes to bring a valuable resource to the public research community. However, the real interest and benefit of the research community is not easy to quantify. We analyse here the feedback on the Messidor database, after more than 6 years of diffusion. This analysis should apply to other similar research databases.
The automatic detection of exudates in color eye fundus images is an important task in applications such as diabetic retinopathy screening. The presented work has been undertaken in the framework of the TeleOphta project, whose main objective is to automatically detect normal exams in a tele-ophthalmology network, thus reducing the burden on the readers. A new clinical database, e-ophtha EX, containing precisely manually contoured exudates, is introduced. As opposed to previously available databases, e-ophtha EX is very heterogeneous. It contains images gathered within the OPHDIAT telemedicine network for diabetic retinopathy screening. Image definition, quality, as well as patients condition or the retinograph used for the acquisition, for example, are subject to important changes between different examinations. The proposed exudate detection method has been designed for this complex situation. We propose new preprocessing methods, which perform not only normalization and denoising tasks, but also detect reflections and artifacts in the image. A new candidates segmentation method, based on mathematical morphology, is proposed. These candidates are characterized using classical features, but also novel contextual features. Finally, a random forest algorithm is used to detect the exudates among the candidates. The method has been validated on the e-ophtha EX database, obtaining an AUC of 0.95. It has been also validated on other databases, obtaining an AUC between 0.93 and 0.95, outperforming state-of-the-art methods.
The software rapidly and accurately analyzed the in vivo confocal micrographs of the healthy central corneas, yielding quantitative results to describe the nerves, dendritic immune cells, and wing cells.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.