Background-Previous studies of pacing therapy for dilated congestive heart failure (CHF) have not established the relative importance of pacing site, AV delay, and patient heterogeneity on outcome. These variables were compared by a novel technique that evaluated immediate changes in hemodynamic function during brief periods of atrial-synchronous ventricular pacing. Methods and Results-Twenty-seven CHF patients with severe left ventricular (LV) systolic dysfunction and LV conduction disorder were implanted with endocardial pacing leads in the right atrium and right ventricle (RV) and an epicardial lead on the LV and instrumented with micromanometer catheters in the LV, aorta, and RV. Patients in normal sinus rhythm were stimulated in the RV, LV, or both ventricles simultaneously (BV) at preselected AV delays in a repeating 5-paced/15-nonpaced beat sequence. Maximum LV pressure derivative (LVϩdP/dt) and aortic pulse pressure (PP) changed immediately at pacing onset, increasing at a patient-specific optimal AV delay in 20 patients with wide surface QRS (180Ϯ22 ms) and decreasing at short AV delays in 5 patients with narrower QRS (128Ϯ12 ms) (PϽ0.0001). Overall, BV and LV pacing increased LVϩdP/dt and PP more than RV pacing (PϽ0.01), whereas LV pacing increased LVϩdP/dt more than BV pacing (PϽ0.01). Conclusions-In this population, CHF patients with sufficiently wide surface QRS benefit from atrial-synchronous ventricular pacing, LV stimulation is required for maximum acute benefit, and the maximum benefit at any site occurs with a patient-specific AV delay. (Circulation. 1999;99:2993-3001.)
Positive responses to left (LV) and biventricular (BV) stimulation observed in heart failure patients with left bundle branch block (LBBB) suggest a possible mechanism of LV resynchronization. An anesthetized canine LBBB model was developed using radio frequency ablation. Before and after ablation, LV pressure derivative over time (dP/dt) and aortic pulse pressure (PP) were assessed during normal sinus rhythm with right ventricle (RV), LV, or BV stimulation combined with four atrioventricular delays in six dogs. In three more dogs, M-mode echocardiograms of septal and LV posterior wall motion were obtained before and after LBBB and during LV stimulation. LBBB caused QRS widening and hemodynamics deterioration. Before ablation, stimulation alone worsened LV dP/dt and PP. After ablation, LV and BV stimulation maximally increased LV dP/dt by 16% and PP by 7% (P < 0.001), whereas little improvement was observed during RV stimulation. M-mode echocardiogram showed that LBBB resulted in a paradoxical septal wall motion that was corrected by LV stimulation. In conclusion, LV and BV stimulation improved cardiac function in a canine LBBB model via resynchronization of LV excitation and contraction.
The new 'over the wire' lead and guiding catheter system allows uncomplicated access to the coronary sinus and the depth of the coronary vein tributaries. Left ventricular sensing and pacing thresholds are acceptable for chronic use in implanted cardiac rhythm management systems.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.