The authors' work was conducted to identify the dose reduction limits of ASiR™ for a pediatric oncology population using automatic tube current modulation. Improvements in noise levels from ASiR™ reconstruction were adapted to provide lower radiation exposure (i.e., lower mA) instead of improved image quality. We have demonstrated for the image quality standards required at our institution, a maximum dose reduction of 82% can be achieved using 100% ASiR™; however, to negate changes in the appearance of reconstructed images using ASiR™ with a medium to low frequency noise preserving reconstruction filter (i.e., standard), 40% ASiR™ was implemented in our clinic for 42%-48% dose reduction at all pediatric ages without a visually perceptible change in image quality or image noise.
Purpose To determine a comprehensive method for the implementation of adaptive statistical iterative reconstruction (ASIR) for maximal radiation dose reduction in pediatric computed tomography (CT) without changing the magnitude of noise in the reconstructed image or the contrast-to-noise ratio (CNR) in the patient. Materials and Methods The institutional review board waived the need to obtain informed consent for this HIPAA-compliant quality analysis. Chest and abdominopelvic CT images obtained before ASIR implementation (183 patient examinations; mean patient age, 8.8 years ± 6.2 [standard deviation]; range, 1 month to 27 years) were analyzed for image noise and CNR. These measurements were used in conjunction with noise models derived from anthropomorphic phantoms to establish new beam current–modulated CT parameters to implement 40% ASIR at 120 and 100 kVp without changing noise texture or magnitude. Image noise was assessed in images obtained after ASIR implementation (492 patient examinations; mean patient age, 7.6 years ± 5.4; range, 2 months to 28 years) the same way it was assessed in the pre-ASIR analysis. Dose reduction was determined by comparing size-specific dose estimates in the pre- and post-ASIR patient cohorts. Data were analyzed with paired t tests. Results With 40% ASIR implementation, the average relative dose reduction for chest CT was 39% (2.7/4.4 mGy), with a maximum reduction of 72% (5.3/18.8 mGy). The average relative dose reduction for abdominopelvic CT was 29% (4.8/6.8 mGy), with a maximum reduction of 64% (7.6/20.9 mGy). Beam current modulation was unnecessary for patients weighing 40 kg or less. The difference between 0% and 40% ASIR noise magnitude was less than 1 HU, with statistically nonsignificant increases in patient CNR at 100 kVp of 8% (15.3/14.2; P = .41) for chest CT and 13% (7.8/6.8; P = .40) for abdominopelvic CT. Conclusion Radiation dose reduction at pediatric CT was achieved when 40% ASIR was implemented as a dose reduction tool only; no net change to the magnitude of noise in the reconstructed image or the patient CNR occurred.
Magnetic Resonance Imaging (MRI) is known to be significantly affected by a number of acquisition artifacts, such as intensity non-standardness, bias field, and Gaussian noise. These artifacts degrade MR image quality significantly, obfuscating anatomical and physiological detail and hence need to be corrected for to facilitate application of computerized analysis techniques such as segmentation, registration, and classification. Specifically, algorithms are required to correct for bias field (intensity inhomogeneity), intensity non-standardness (drift in tissue intensities across patient acquisitions), and Gaussian noise, an artifact that significantly affects and blurs tissue boundaries (resulting in poor gradients). While clearly one needs to correct for all these artifacts, the exact sequence in which all three operations need to be applied in order to maximize MR image quality has not been explored. In this paper, we empirically evaluate the interplay between distinct algorithms for bias field correction (BFC), intensity standardization (IS), and noise filtering (NF) to study the effect of these operations on image quality in the context of 3 Tesla T2-weighted (T2w) prostate MRI. 7 different sequences comprising combinations of BFC, IS, and NF were quantitatively evaluated in terms of the percent coefficient of variation (%CV), a statistic which attempts to quantify the intensity inhomogeneity within a region of interest (prostate). The different combinations were also independently evaluated in the context of a classifier scheme for detection of prostate cancer on high resolution in vivo T2w prostate MRI. A secondary contribution of this work is a novel evaluation measure for quantifying the level of intensity non-standardness, called difference of modes (DoM). Experimental evaluation of the different sequences of operations across 22 patient datasets revealed that the sequence of BFC, followed by NF, and IS provided the best image quality in terms of %CV as well as classifier accuracy. The DoM measure was able to accurately capture the level of intensity non-standardness present in the images resulting from the different sequences of operations.
Background It is unclear if routine pelvic imaging is needed in patients with Wilms’ tumor. Thus, our primary objective examined the role of routine pelvic computed tomography (CT) in a cohort of pediatric patients with Wilms’ tumor. Methods With IRB approval we retrospectively identified 110 Wilms’ tumor patients diagnosed between January 1999 and December 2009; surveillance imaging continued through March 2011. We estimated survival (OS) and event-free survival (EFS), and dosimetry from dose length product (DLP) conversion to effective dose (ED) for every CT in a subgroup of 80 patients scanned using contemporary scanners (2002–2011). MOSFET dosimeters were placed within organs of anthropomorphic phantoms to directly calculate truncal ED. EDDLP was correlated with EDMOSFET to calculate potential pelvic dose savings. Results Eighty patients underwent 605 CT examinations containing DLP information: 352 chest, abdomen and pelvis, 123 chest-abdomen, 102 chest only, 18 abdomen-pelvis, 9 abdomen only, one limited to pelvis. Respective 5-year OS and EFS estimates were 92.8% ± 3.0% and 2.6% ± 4.3%. Sixteen patients (16/110; 15%) relapsed a median of 11.3 months (range, 5.0 months to 7.3 years) after diagnosis; four died of disease recurrence. Three patients developed pelvic relapse, all symptomatic. Estimated ED savings from gender-neutral CT surveillance performed at 120 kVp without pelvic imaging was calculated: 30.5%, 30.4%, 39.4%, and 44.9% for the average 1, 5, 10, and 15 year old patient, respectively. Conclusions Omitting pelvic CT from routine off-therapy follow-up of Wilms’ tumor patients saves an average 30–45% effective dose without compromising disease detection.
Purpose-To determine a comprehensive method for the implementation of adaptive statistical iterative reconstruction (ASIR) for maximal radiation dose reduction in pediatric computed tomography (CT) without changing the magnitude of noise in the reconstructed image or the contrast-to-noise ratio (CNR) in the patient.Materials and Methods-The institutional review board waived the need to obtain informed consent for this HIPAA-compliant quality analysis. Chest and abdominopelvic CT images obtained before ASIR implementation (183 patient examinations; mean patient age, 8.8 years ± 6.2 [standard deviation]; range, 1 month to 27 years) were analyzed for image noise and CNR. These measurements were used in conjunction with noise models derived from anthropomorphic phantoms to establish new beam current-modulated CT parameters to implement 40% ASIR at 120 and 100 kVp without changing noise texture or magnitude. Image noise was assessed in images obtained after ASIR implementation (492 patient examinations; mean patient age, 7.6 years ± 5.4; range, 2 months to 28 years) the same way it was assessed in the pre-ASIR analysis. Dose reduction was determined by comparing size-specific dose estimates in the pre-and post-ASIR patient cohorts. Data were analyzed with paired t tests.Results-With 40% ASIR implementation, the average relative dose reduction for chest CT was 39% (2.7/4.4 mGy), with a maximum reduction of 72% (5.3/18.8 mGy). The average relative dose reduction for abdominopelvic CT was 29% (4.8/6.8 mGy), with a maximum reduction of 64% (7.6/20.9 mGy). Beam current modulation was unnecessary for patients weighing 40 kg or less. The difference between 0% and 40% ASIR noise magnitude was less than 1 HU, with statistically Address correspondence to S.L.B. (samuel.brady@stjude.org). 2 Current address: Department of Physics, Tuskegee University, Tuskegee, Ala.Online supplemental material is available for this article. Author contributions:Guarantors of integrity of entire study, S.L.B., R.A.K.; study concepts/study design or data acquisition or data analysis/ interpretation, all authors; manuscript drafting or manuscript revision for important intellectual content, all authors; manuscript final version approval, all authors; literature research, S.L.B., B.M.M., B.S.Y.; clinical studies, all authors; experimental studies, all authors; statistical analysis, S.L.B.; and manuscript editing, all authors Conflicts of interest are listed at the end of this article. Disclosures of Conflicts of HHS Public Access Author ManuscriptAuthor Manuscript Author ManuscriptAuthor Manuscript nonsignificant increases in patient CNR at 100 kVp of 8% (15.3/14.2; P = .41) for chest CT and 13% (7.8/6.8; P = .40) for abdominopelvic CT.Conclusion-Radiation dose reduction at pediatric CT was achieved when 40% ASIR was implemented as a dose reduction tool only; no net change to the magnitude of noise in the reconstructed image or the patient CNR occurred.Reducing radiation dose for pediatric patients undergoing computed tomography (CT) exami...
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.