SUMMARYObjective: In 2014 the European Union-funded E-PILEPSY project was launched to improve awareness of, and accessibility to, epilepsy surgery across Europe. We aimed to investigate the current use of neuroimaging, electromagnetic source localization, and imaging postprocessing procedures in participating centers. Methods: A survey on the clinical use of imaging, electromagnetic source localization, and postprocessing methods in epilepsy surgery candidates was distributed among the 25 centers of the consortium. A descriptive analysis was performed, and results were compared to existing guidelines and recommendations. Results: Response rate was 96%. Standard epilepsy magnetic resonance imaging (MRI) protocols are acquired at 3 Tesla by 15 centers and at 1.5 Tesla by 9 centers. Three centers perform 3T MRI only if indicated. Twenty-six different MRI sequences were reported. Six centers follow all guideline-recommended MRI sequences with the proposed slice orientation and slice thickness or voxel size. Additional sequences are used by 22 centers. MRI postprocessing methods are used in 16 centers. Interictal positron emission tomography (PET) is available in 22 centers; all using 18F-fluorodeoxyglucose (FDG). Seventeen centers perform PET postprocessing. Single-photon emission computed tomography (SPECT) is used by 19 centers, of which 15 perform postprocessing. Four centers perform neither PET nor SPECT in children. Seven centers apply magnetoencephalography (MEG) source localization, and nine apply electroencephalography (EEG) source localization. Fourteen combinations of inverse methods and volume conduction models are used. Significance: We report a large variation in the presurgical diagnostic workup among epilepsy surgery centers across Europe. This diversity underscores the need for highquality systematic reviews, evidence-based recommendations, and harmonization of available diagnostic presurgical methods.
Objective: The European Union-funded E-PILEPSY network (now continuing within the European Reference Network for rare and complex epilepsies [Epi-CARE]) aims to harmonize and optimize presurgical diagnostic procedures by creating and implementing evidence-based guidelines across Europe. The present study evaluates the current evidence on the diagnostic accuracy of long-term video-electroencephalographic monitoring (LTM) in identifying the epileptogenic zone in epilepsy surgery candidates. Methods: MEDLINE, Embase, CENTRAL, and ClinicalTrials.gov were searched for relevant articles. First, we used random-effects meta-analytical models to calculate pooled estimates of sensitivity and specificity with respect to postsurgical seizure freedom. In a second phase, we analyzed individual patient data in an exploratory fashion, assessing diagnostic accuracy within lesional and nonlesional temporal lobe epilepsy (TLE) and extratemporal lobe epilepsy (ETLE) patients. We also evaluated seizure freedom rate in the presence of "localizing" or "nonlocalizing" LTM within each group. The quality of evidence was assessed using the QUADAS-2 tool and the GRADE approach. Results: Ninety-four studies were eligible. Forty-four were included in sensitivity meta-analysis and 34 in specificity meta-analysis. Pooled sensitivity was 0.70 (95% confidence interval [CI] = 0.60-0.80) and specificity was 0.40 (95% CI = 0.27-0.54). Subgroup analysis was based on individual data of 534 patients (41% men).In lesional TLE patients, sensitivity was 0.85 (95% CI = 0.81-0.89) and specificity was −0.19 (95% CI = 0.13-0.28). In lesional ETLE patients, a sensitivity of 0.47 (95% CI = 0.36-0.58) and specificity of 0.35 (95% CI = 0.21-0.53) were observed. ---In lesional TLE, if LTM was localizing and concordant with resection site, the seizure freedom rate was 247 of 333 (74%), whereas in lesional ETLE it was 34 of 56 (61%). The quality of evidence was assigned as "very low." Significance: Long-term video-electroencephalographic monitoring is associated with moderate sensitivity and low specificity in identification of the epileptogenic zone. Sensitivity is remarkably higher in lesional TLE compared to lesional ETLE. Substantial heterogeneity across the studies indicates the need for improved design and quality of reporting. K E Y W O R D Sepilepsy surgery, seizure outcome, sensitivity, specificity, video-EEG
Interictal high resolution (HR-) electric source imaging (ESI) and magnetic source imaging (MSI) are non-invasive tools to aid epileptogenic zone localization in epilepsy surgery candidates. We carried out a systematic review on the diagnostic accuracy and quality of evidence of these modalities. MethodsEmbase, Pubmed and the Cochrane database were searched on 13 February 2017.Diagnostic accuracy studies taking post-surgical seizure outcome as reference standard were selected. Quality appraisal was based on the QUADAS-2 framework. ResultsEleven studies were included: eight MSI (n=267), three HR-ESI (n=127) studies. None was free of bias. This mostly involved: selection of operated patients only, interference of source imaging with surgical decision, and exclusion of indeterminate results. Summary sensitivity and specificity estimates were 82% (95% CI: 75-88%) and 53% (95% CI: 37-68%) for overall source imaging, with no statistical difference between MSI and HR-ESI. Specificity is higher when partially concordant results were included as non-concordant (p<0.05). Inclusion of indeterminate test results as non-concordant lowered sensitivity (p<0.05). ConclusionsSource imaging has a relatively high sensitivity but low specificity for identification of the epileptogenic zone. SignificanceWe need higher quality studies allowing unbiased test evaluation to determine the added value and diagnostic accuracy of source imaging in the presurgical workup of refractory focal epilepsy. Highlights Interictal source imaging studies are biased and show heterogeneity for population and test method Source imaging sensitivity and specificity was 82% (95% CI: 75-88%) and 53% (37-68%) respectively Diagnostic accuracy for (extra)temporal and (non)-lesional patients show no statistical differences
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.