Image‐based assessments of quadriceps muscle size facilitate examination of structural changes after anterior cruciate ligament (ACL) injury and reconstruction (ACLR). Understanding the effects of ACLR on muscle size measures may aid in clarifying the contribution of quadriceps atrophy toward quadriceps strength. The purpose of this study was to systematically review the literature examining the effects of ACLR on quadriceps muscle volume and cross‐sectional area (CSA). An online database search was conducted using Web of Science, SportDISCUS, PubMed (Medline), CINHAL (EBSCO), and Cochrane Library limited to articles published after January 1, 1980. Means and standard deviations were extracted for the ACLR limb and the contralateral limb, and sample characteristics from relevant articles. Magnitude of between limb differences were assessed using pooled effect sizes (Hedge's g) and 95% confidence intervals. Eleven articles (five CSA, six muscle volume) were included in this systematic review. Included studies reported negative effective sizes, indicating that the ACLR limb was smaller in CSA or muscle volume compared with the contralateral limb; however, 36% of the included articles reported meaningful difference between the limbs. Quadriceps atrophy may occur following ACL injury and persist after rehabilitation, however, the magnitude of these reductions may not be clinically meaningful and may only partially explain the persistent quadriceps weakness that is ubiquitous among this patient population. © 2019 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 38:598–608, 2020
Background This study aimed to determine the impact of pulmonary complications on death after surgery both before and during the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) pandemic. Methods This was a patient-level, comparative analysis of two, international prospective cohort studies: one before the pandemic (January–October 2019) and the second during the SARS-CoV-2 pandemic (local emergence of COVID-19 up to 19 April 2020). Both included patients undergoing elective resection of an intra-abdominal cancer with curative intent across five surgical oncology disciplines. Patient selection and rates of 30-day postoperative pulmonary complications were compared. The primary outcome was 30-day postoperative mortality. Mediation analysis using a natural-effects model was used to estimate the proportion of deaths during the pandemic attributable to SARS-CoV-2 infection. Results This study included 7402 patients from 50 countries; 3031 (40.9 per cent) underwent surgery before and 4371 (59.1 per cent) during the pandemic. Overall, 4.3 per cent (187 of 4371) developed postoperative SARS-CoV-2 in the pandemic cohort. The pulmonary complication rate was similar (7.1 per cent (216 of 3031) versus 6.3 per cent (274 of 4371); P = 0.158) but the mortality rate was significantly higher (0.7 per cent (20 of 3031) versus 2.0 per cent (87 of 4371); P < 0.001) among patients who had surgery during the pandemic. The adjusted odds of death were higher during than before the pandemic (odds ratio (OR) 2.72, 95 per cent c.i. 1.58 to 4.67; P < 0.001). In mediation analysis, 54.8 per cent of excess postoperative deaths during the pandemic were estimated to be attributable to SARS-CoV-2 (OR 1.73, 1.40 to 2.13; P < 0.001). Conclusion Although providers may have selected patients with a lower risk profile for surgery during the pandemic, this did not mitigate the likelihood of death through SARS-CoV-2 infection. Care providers must act urgently to protect surgical patients from SARS-CoV-2 infection.
Background Metal sensitivity as a cause for painful joint replacement has become increasingly prevalent; however, there is a lack of reported clinical outcome data from total knee arthroplasty patients with metal allergies. The purpose of this study was to determine whether patients presenting with a painful total knee arthroplasty with a positive metal sensitivity have improved outcomes following revision to a hypoallergenic implant. Methods A retrospective review was conducted for patients that underwent a revision total knee arthroplasty after metal sensitivity testing over a 3-year period from January 1, 2015, to December 31, 2017. Based on the results of sensitivity testing, patients underwent revision total knee arthroplasty to a hypoallergenic component or a standard component. Following revision, patients returned to the clinic at an interval of 6 weeks, 5 months, and 12 months for functional, pain, and satisfaction assessment. Outcomes were compared within and between sensitivity groups. Results Of the included patients, 78.3% (39/46) were positive for metal sensitivity. The most common metal sensitivity was to nickel (79.5%, 32/39). Both non-reactive and reactive patients significantly improved in range of motion after revision arthroplasty. The reactive group saw a 37.8% decrease in pain at 6 weeks post-revision ( p < 0.001) Whereas, the non-reactive group only saw a moderate, non-significant improvement in pain reduction at 6 weeks post-revision (27.0%; p = 0.29). Frequency of pain experienced did not vary significantly between groups. Maximum metal lymphocyte transformation test (LTT) sensitivity score did not correlate with pain level at the time of revision ( R 2 = 0.02, p = 0.38) or percent improvement after revision ( R 2 = 0.001, p = 0.81). Overall, all patients reported being very satisfied after revision total knee arthroplasty; there was no difference between positive and negative sensitivity groups ( W = 62, p = 0.89). Conclusions Patients presenting with a painful knee arthroplasty and positive metal LTT have improved pain scores, walking function, and range of motion following revision to a hypoallergenic component. This study also provides a treatment algorithm for patients presenting with a painful knee replacement, in order to provide effective and timely diagnosis and management. Electronic supplementary material The online version of this article (10.1186/s13018-019-1228-4) contains supplementary material, which is available to authorized users.
Quadriceps muscle weakness is a commonly reported issue post anterior cruciate ligament reconstruction (ACLR), with minimal information related to skeletal muscle morphology following surgery. The purpose is to examine the morphological and functional differences in the vastus lateralis muscle from patient's ACLR and contralateral leg. Three physically active ACLR participants were recruited and secured to a dynamometer to perform maximal voluntary isometric knee extension contractions (MVIC) of the ACLR and contralateral limb. Muscle biopsies of the ACLR and contralateral vastus lateralis were performed, then sectioned, and stained for myosin isoforms to determine fiber type. Confocal images were acquired, and ImageJ software was used to determine the fiber type and cross-sectional area (CSA). There was a significant reduction in CSA of the type IIa and type IIx muscle fiber cells between healthy (IIa: 7,718 ± 1,295 µm2; IIx; 5,800 ± 601 µm2) and ACLR legs (IIa: 4,139 ± 709 µm2; IIx: 3,708 ± 618 µm2) (p < 0.05), while there was no significant difference in knee extension MVIC torque between legs (healthy limb: 2.42 ± 0.52 Nm/kg; ACLR limb: 2.05 ± 0.24 Nm/kg, p = 0.11). The reduction in the cross-sectional area of the ACLR type II fibers could impair function and increase secondary injury risk.
This case report looks at the failure of a vitamin E-infused highly cross-linked polyethylene acetabular liner that fractured at the superior rim of the locking mechanism. This calls to question whether there is a problem with the vitamin E-infused product or a flaw in the design of the liner or possibly a combination of the 2. Although there has been discussion of a possible minimum rim polyethylene thickness, there has not been a minimum thickness established. In addition, in the case of offset liners, indentations which are a part of a locking mechanism can cause the minimum rim dimension to be much less than the specified nominal thickness. This case serves as an interesting observation and contributes to the discussion of rim liner polyethylene thickness and minimum rim thickness.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.