The purpose of this study was to investigate the impact of processing, API loading, and formulation composition on the content uniformity of low-dose tablets made using direct compression (DC) and roller compaction (RC) methods at 1 kg scale. Blends of 1:1 microcrystalline cellulose/lactose or 1:1 microcrystalline cellulose/dicalcium phosphate anhydrous with active pharmaceutical ingredient (API) at loadings of 0.2, 1 and 5% were processed either by DC or RC. A statistical analysis showed that DC produced comparable content uniformity results to RC. Microcrystalline cellulose/lactose formulations had improved average potency compared to microcrystalline cellulose/dicalcium phosphate anhydrous formulations for both DC and RC. The impact of segregation in the DC blends and adhesion to equipment surfaces was assessed to aid in understanding potency trends. DC may be as suitable as RC for low-dose regime (e.g. < 1 mg) when manufacturing clinical supplies at small scale provided the API has a suitable particle size and potency loss to equipment is negligible.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.