The sensitivity and dynamic range of optical coherence tomography (OCT) are calculated for instruments utilizing two common interferometer configurations and detection schemes. Previous researchers recognized that the performance of dual-balanced OCT instruments is severely limited by beat noise, which is generated by incoherent light backscattered from the sample. However, beat noise has been ignored in previous calculations of Michelson OCT performance. Our measurements of instrument noise confirm the presence of beat noise even in a simple Michelson interferometer configuration with a single photodetector. Including this noise, we calculate the dynamic range as a function of OCT light source power, and find that instruments employing balanced interferometers and balanced detectors can achieve a sensitivity up to six times greater than those based on a simple Michelson interferometer, thereby boosting image acquisition speed by the same factor for equal image quality. However, this advantage of balanced systems is degraded for source powers greater than a few milliwatts. We trace the concept of beat noise back to an earlier paper [J. Opt. Soc. Am. 52, 1335 (1962)].
, "Limits to performance improvement provided by balanced interferometers and balanced detection in OCT/OCM instruments", Proc. SPIE 5316, 467 (2004) ABSTRACTWe compare the dynamic range of OCT/OCM instruments configured with unbalanced interferometers, e.g., Michelson interferometers, with that of instruments utilizing balanced interferometers and balanced photodetection. We define the dynamic range (DR) as the ratio of the maximum fringe amplitude achieved with a highly reflecting surface to the rootmean-square (rms) noise. Balanced systems achieve a dynamic range 2.5 times higher than that of a Michelson interferometer, enabling an image acquisition speed roughly 6 times faster. This maximum improvement occurs at light source powers of a few milliwatts. At light source powers higher than 30 mW, the advantage in acquisition speed of balanced systems is reduced to a factor of 4. For video-rate imaging, the increased cost and complexity of a balanced system may be outweighed by the factor of 4 to 6 enhancement in image acquisition speed. We include in our analysis the "beat-noise" resulting from incoherent light backscattered from the sample, which reduces the advantage of balanced systems. We attempt to resolve confusion surrounding the origin and magnitude of "beat-noise", first described by L. Mandel in 1962. Beat-noise is present in both balanced and unbalanced OCT/OCM instruments.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.