The aim of the current paper is to review the available literature reporting on comparative studies of heat-cured resins and three-dimensionally printed biomaterials for denture bases in terms of their composition, properties, fabrication techniques and clinical performance. The methodology included applying a search strategy, defining inclusion and exclusion criteria, selecting studies to summarize the results. Searches of PubMed, Scopus, and Embase databases were performed independently by three reviewers to gather literature published between 2018 and 2021. A total of 135 titles were obtained from the electronic databases, and the application of exclusion criteria resulted in the identification of 42 articles pertaining to conventional and 3D printed technology for removable dentures. The main disadvantages of the heat-cured resins for removable dentures are that they require lots of special equipment, skilled personnel and time. Emerging technologies, such as 3D printed dentures, have the potential to alleviate these problems allowing for faster patient rehabilitation. With the development of digital dentistry, it is becoming increasingly necessary to use 3D printed resin materials for the manufacturing of removable dentures. However, further research is required on the existing and developing materials to allow for advancement and increase its application in removable prosthodontics.
The aim of the current study was to evaluate the dimensional changes and ultimate tensile strength in three polyamide materials for denture bases fabrication through injection molding, subjected to artificial aging and different storage conditions. A total of 333 test specimens fabricated from Biosens (BS; Perflex, Netanya, Israel), Bre.flex 2nd edition (BF; Bredent, Senden, Germany) and ThermoSens (TS; Vertex Dental B.V., Soesterberg, The Netherlands)—n = 111 per material—were equally divided into three groups (n = 37) based on different treatments and storage conditions. Test samples allocated to the “Control group” were not artificially aged and stored in water for 24 h. Both “Treatment 1 group” and “Treatment 2 group” were subjected to thermocycling, the former dehydrated and the latter stored in water between cycle-sets. Linear changes and ultimate tensile strength were measured and analyzed for storage condition and material influence on the outcome variables. A Welch ANOVA test with Games–Howell post-hoc analysis was used to compare the influence of treatments across different materials. Significant differences were found for all three included materials with p values ranging from <0.05 to <0.001 for linear dimensional changes. The magnitude of alterations varied and was large for BS (Perflex, Israel) (ω2 = 0.62) and BF (Bredent, Germany) (ω2 = 0.47) and small but significant for TS (Vertex Dental B.V., The Netherlands) (ω2 = 0.05). However, results seem to fall into clinically acceptable range. Significant differences were also observed for the ultimate tensile strength test with the same range of p-values. All three materials showed different initial ultimate tensile strengths and varying reaction to artificial aging and storage with the lowest alterations observed for BF (Bredent, Germany) (ω2 = 0.05). Within the limitation of this study, it can be concluded that all three materials show different dimensional and mechanical properties when subjected to artificial aging and different storage. Although linear dimensions show significant changes, they seem to be clinically irrelevant, whereas the change in ultimate tensile strength after only 6-month equivalent clinical use was substantial for BS (Perflex, Israel) and TS (Vertex Dental B.V., The Netherlands).
This study investigated the colour stability of three dimensional (3D)-printed and conventional denture teeth after immersion in different colourants. A total of 60 artificial maxillary central incisors were selected from three types of materials: 3D-printed dental resin (NextDent, 3D Systems, Soesterberg, The Netherlands), prefabricated acrylic teeth in Ivostar Shade (Ivoclar Vivadent, Schaan, Liechtenstein), and SpofaDent Plus in shade A2 (SpofaDental, Jičín, Czechia). These were immersed in four types of colourants at room temperature (23 °C ± 1 °C), including artificial saliva (pH = 6.8) as a control group, coffee, red wine, and Coca-Cola (n = 5). The temperature and the pH of the colouring agents were maintained throughout all immersion periods. After 7 days (T1), 14 days (T2), and 21 days (T3), the ∆E values were measured with a SpectroShade Micro (SpectroShade, Oxnard, CA, USA) spectrophotometer. Their means were then calculated and compared by two-way ANOVA. The independent factors, immersion time and different staining solutions, as well as the interaction between these factors, significantly influenced ΔE. The highest and the lowest mean ∆Es were recorded for prefabricated teeth in red wine, and 3D-printed teeth in artificial saliva, respectively. All the specimens demonstrated an increased colour change at T1 compared to T3, and the difference in mean ∆E was statistically significant.
Contemporary thermoplastic monomer-free prosthetic materials are widely used nowadays, and there are a great variety available on the market. These materials are of interest in terms of the improvement of the quality features of the removable dentures. The aim of this study is to establish how minimal changes in the laboratory protocol of polyamide prosthetic base materials influence the surface texture. Two polyamide materials intended for the fabrication of removable dentures bases were used—Perflex Biosens (BS) and VertexTM ThermoSens (TS). A total number of 20 coin-shaped samples were prepared. They were injected under two different modes—regular, as provided by the manufacturer, and modified, proposed by the authors of this study. Scanning electronic microscopy (SEM) under four magnifications—×1000, ×3000, ×5000, and ×10,000—was conducted. With minimal alterations to the melting temperature (5 °C) and the pressure (0.5 Bar), in Biosens, no changes in terms of surface improvement were found, whereas in ThermoSens, the surface roughness of the material significantly changed in terms of roughness reduction. By modifying the technological mode during injection molding, a smoother surface was achieved in one of the studied materials.
Objective: To evaluate the change of diameter of different injection-molded thermoplastic materials. Material and Methods: Four thermoplastic injection-molded materials were analyzed (Bre.flex 2 nd edition, Vertex ThermoSens, Perflex Biosens and Polyan IC). A total of 432 test samples were made in the form of an "hourglass". All samples were divided into three groups: Group I (Control) -consisting of 36 test samples for each type of material, that was not exposed to artificial aging or a wet environment; Group II -consisting of 36 test samples for each type of material, that were artificially aged through dehydration; Group III -specimen were subjected to artificial aging without dehydration. The diameter of each specimen was measured with a digital caliper. Data were analysed using the Student's t-test. Results: Regarding to shrinkage, the samples from the Bf Control group have a mean value of 1.56 mm and was observed a shrinkage of the injection-molded polyamide material within 0.25%. The comparison between the samples from Group II and Group III showed statistically significant differences (p<0.001). There were no significant differences between groups for Thermosens and Biosens (p>0.05). The comparison between Group II and Group III for Polyan IC samples shows that Group III has a higher arithmetic mean value (p<0.01). Conclusion: Shrinkage of the polymers during the injection process is present in all materials. The thermocycling and the storage in a dry or in a wet environment of the samples results in a change of the diameter in almost every single type of material.
Introduction:Simulation tests may significantly decrease the cost and time needed for planning and production of prosthetic restorations, providing both computer simulation as part of the refinement process and experimental testing. Aim: Comparative simulation testing with functional loading of two denture framework materials. Materials and methods: Upper model cast denture forbilateral edentulous areas posterior to the natural teeth (Kennedy Class I) was produced on the "Frasaco" phantom model. The denture was scanned by a 3D optical laboratory scanner. The 3D model was transformed into an STL-file and was processed with "Cinema 4D" software before the application of the program "SOLIDWORKS" v.2018. Parameters of two materials – metal alloy I-MG EKO (Interdent, Slovenia) and injection molded resin Bio Dentaplast (Bredent, Germany) were applied. Simulations were performed by equivalent loading according to the Third strength theory (von Mises stress-test) and loading with deformation and shift at constant force 0.1N/mm2 at a maximal number of 159 181 segmented elements of the 3D object. Tests were held upon unilateral loading on the working side, and support was provided by reciprocal clasp arms on the working and non-working side, denture flanges and major connector. Results and discussion: Results showed insignificant differences between the common reflected load of the two tested materials but with different distribution - on the major connector, it was 0.4N for the alloy and 0.87N for the resin, at the flanges – 2.26N and 5.6N respectively, for the clasps – 5.1N and 5.7N. Conclusion: The tested metal alloy is rigid and resistant material which provides distribution of the reflected load between clasp elements and denture saddle, especially distally, while the the tested injection molded material possesses relatively high flexibility and elasticity, which hides a risk for the teeth bearing clasps.
ABSTRACT:Thermoplastic materials (TMs) are used more than a century in dentistry worldwide, but in Bulgaria, there is limited information about their properties and indications. These materials let the specialists widen the application of full and partial dentures even in difficult clinical cases. Objective: A survey regarding the awareness of the properties, the drawbacks and the indications of the thermoplastic materials for dental purposes in Bulgaria. Material and method: Inquiry ranged from April 2016 until October 2016. The participants were 289 dentist and dental technicians in Bulgaria. The questions regard area of expertise, gender, age, years of experience; awareness of the types of TMs, members and working protocol; properties of the materials, personal observations of the participants. Results: Most of the participants work in a private practice, and half of them are familiar with the TMs in general. Conclusion: This study shows that 52% of the participants are aware of have some information about TM, 82% of them know the polyamides, 25% the thermoplastic acrylic resins, 15% polyoxymethylene, 4% polyolefin and only 1,5% Polyan. 42% use these materials in their practice and are familiar with the technological and working protocol and only 36% report that they are aware of their properties, disadvantages and indications.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.