Many different materials are available for grafting during surgery for Peyronie's disease (PD). To study the outcomes associated with the use of a lyophilized bovine pericardium graft (Peri-Guard®) to repair tunical defects in patients with PD, descriptive study of 43 patients with disabling penile curvature was performed. Curvature was measured before and after the intervention using a standardized procedure. Surgical technique was plaque excision and grafting of the tunical defect carried out by a single surgeon. A lyophilized bovine pericardium patch was used for grafting. We measured the change in penile curvature and length, the ability to perform successful sexual intercourse without further pharmacological or surgical treatment, and the satisfaction with treatment. Follow-up data were available for a total of 41 patients. Median age was 50 years (IQR 48–52); mean follow-up time was 14 ± 6 months. Complete penile straightening was achieved in 33 patients (80.5%) and five patients (12.2%) had curvature under 20°. Three months after surgery and stretching therapy, mean (s.d.) flaccid penile length increased from 11.2 ± 2.8 cm to 12.1 ± 2.9 cm (P = 0.062). Seventy-five percentage of patients reported being able to achieve successful intercourse without further treatment. Eighty-five percentage of patients reported to be satisfied with the treatment. There was no evidence of tissue rejection or infection, and only four patients suffered an adverse event. Plaque excision and grafting of the tunical defect with lyophilized bovine pericardium seems to be a safe and effective treatment for patients with PD.
Most widespread three-component penile prosthesis models are 700CX™ and Titan®. Our purpose is to assess patient and partner satisfaction after the first implant. This is a multicenter, retrospective, nonrandomized study in which all patients who met the inclusion criteria between 2009 and 2013 were included. In total, 248 patients agreed to participate. To evaluate patient satisfaction, a validated but modified 11-question questionnaire was completed (EDITS); and a nonvalidated two-item questionnaire was given to the partner. Statistical analysis used an ordinal logistic regression model. Two hundred and forty-eight patients (194 with 700CX™
vs 54 with Titan®) and 207 couples completed the questionnaire (165 with 700CX™
vs 42 with Titan®). Overall satisfaction was high. Both showed great reliability for sexual intercourse and high compliance with prior expectations. Most patients were able to manage the penile prosthesis correctly within 6 months. Postoperative penile shortening led to some dissatisfaction in 42% and 46% of cases (700CX™ /Titan®). Significant differences were found in three questions of patients’ questionnaire. There were more patients satisfied with the 700CX™ (P = 0.0001). No patient with Titan® implant took longer than 6 months to optimal management. Only 4% of patients with 700CX™ implant were dissatisfied with the deflation, in contrast to 24% with the Titan® (P = 0.0031). Of the two partners’ questions, one showed a statistically significant difference (P = 0.0026). It seems that group 700CX™ would recommend to re-implant the prosthesis with a greater tendency. The overall satisfaction was very high for both prostheses. The final aspect of the erected and flaccid penis was satisfactory, but both groups showed significant discontent with its final size. Partners’ overall satisfaction was high.
Objectives
To assess the impact of transrectal versus transperineal prostate biopsy on erectile function.
Methods
This was a single‐center, observational, prospective study of consecutive patients who underwent a prostate biopsy (transrectal or transperineal/fusion biopsy). Study participants completed the International Index of Erectile Function‐5 questionnaire before the procedure, and 3 and 6 months after. Prostatic biopsies were carried out following the standard procedure for both techniques.
Results
The study included 135 male patients with a mean age of 63.5 years. At baseline, 28 patients (21%) presented normal erectile function, whereas 107 patients (82%) presented erectile dysfunction, which was severe in four (3%), moderate in 49 (36%) and mild in 54 (40%), with an overall mean International Index of Erectile Function‐5 score of 17.70. After 3 months, the rates were 29%, 3%, 27% and 38%, respectively (mean International Index of Erectile Function‐5 score 17.95). At 6 months, the rates were 30%, 6%, 28% and 34%, respectively (mean International Index of Erectile Function‐5 score of 17.77). No significant differences between pre‐ and post‐biopsy International Index of Erectile Function‐5 scores at 3 and 6 months were observed, even when analyzing transrectal and transperineal separately. The number of biopsy cores and number of previous biopsies did not influence the International Index of Erectile Function‐5 scores.
Conclusions
Our findings suggest that prostate biopsy technique, number of biopsy cores and history of previous biopsy do not significantly impact erectile function in the medium term up to 6 months.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.