BackgroundStudies from high-income countries have shown that women receive less aggressive diagnostics and treatment than men in acute coronary syndromes (ACS), though their short-term mortality does not appear to differ from men. Data on gender differences in ACS presentation, management, and outcomes are sparse in India.Methods and ResultsThe Detection and Management of Coronary Heart Disease (DEMAT) Registry collected data from 1,565 suspected ACS patients (334 women; 1,231 men) from ten tertiary care centers throughout India between 2007–2008. We evaluated gender differences in presentation, in-hospital and discharge management, and 30-day death and major adverse cardiovascular event (MACE; death, re-hospitalization, and cardiac arrest) rates. Women were less likely to present with STEMI than men (38% vs. 55%, p<0.001). Overall inpatient diagnostics and treatment patterns were similar between men and women after adjustment for potential confounders. Optimal discharge management with aspirin, clopidogrel, beta-blockers, and statin therapy was lower for women than men, (58% vs. 65%, p = 0.03), but these differences were attenuated after adjustment (OR = 0.86 (0.62, 1.19)). Neither the outcome of 30-day mortality (OR = 1.40 (0.62, 3.16)) nor MACE (OR = 1.00 (0.67, 1.48)) differed significantly between men and women after adjustment.ConclusionsACS in-hospital management, discharge management, and 30-day outcomes did not significantly differ between genders in the DEMAT registry, though consistently higher treatment rates and lower event rates in men compared to women were seen. These findings underscore the importance of further investigation of gender differences in cardiovascular care in India.
Objective:To evaluate the effect of percutaneous closure of patent ductus arteriosus (PDA) on left ventricular (LV) systolic and diastolic function in children.Background:Limited studies are available on alteration in LV hemodynamics, especially diastolic function, after PDA closure.Methods:Thirty-two consecutive children with isolated PDA treated by trans-catheter closure were studied. The LV systolic and diastolic function were assessed by two-dimensional (2D) echocardiography and tissue Doppler imaging 1 day before the PDA closure, on day 1, and on follow-up.Results:At baseline, none of the patients had LV systolic dysfunction. On day 1 post-PDA closure, 8 (25%) children developed LV systolic dysfunction. The baseline LV ejection fraction (LVEF), LV end-systolic dimension (LVESD), and PDA diastolic gradient predicted the post-closure LVEF. Patients who developed post-closure LV systolic dysfunction had poorer LV diastolic function than those who did not. LV diastolic properties improved after PDA closure; however, the improvement in LV diastolic properties lagged behind the improvement in the LV systolic function. All children were asymptomatic and had normal LVEF on follow up of >3 months.Conclusions:Percutaneous closure of PDA is associated with the reversible LV systolic dysfunction. Improvement in the LV diastolic function lags behind that in the LV systolic function.
The Warden technique is a simple and effective surgical option, which should be preferred for patients with anomalous drainage of the pulmonary veins to SVC. Though arrhythmias are rare in the early follow-up, longer follow-up is required to rule out their late development.
Background:Selecting the device size using a sizing balloon could oversize the ostium secundum atrial septal defect (OSASD) with floppy margins and at times may lead to complications. Identifying the firm margins using trans-esophageal echocardiography (TEE) and selecting appropriate-sized device optimizes ASD device closure. This retrospective study was undertaken to document the safety and feasibility of device closure without balloon sizing the defect.Methods:Sixty-one consecutive patients who underwent trans-catheter closure of OSASD guided by balloon sizing of the defect and intra procedural fluoroscopy (group I) and 67 consecutive patients in whom TEE was used for defect sizing and as intraprocedural imaging during device deployment (group II) were compared. The procedural success rate, device characteristics, and complications were compared between the two groups.Results:The procedure was successful in 79.7 % patients. The success rate in group II (60 of 67, 89.6%) was significantly higher than in group I (41 of 61, 67.2 %) (P = 0.002). Mean upsizing of ASD device was significantly lower in group II (P < 0.001). TEE also provided better success rate with smaller device in subjects with large ASD (>25 mm) and in those who were younger than 14 years of age. There were four cases of device embolization (two in each group); of which one died in group II despite successful surgical retrieval.Conclusion:Balloon sizing may not be essential for successful ASD device closure. TEE-guided sizing of ASD and device deployment provides better success rate with relatively smaller sized device.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.