This paper presents a single-axis angular rate sensor that is robust to variations in its operating voltage and frequencies. The sensor is developed to overcome the shortcomings of conventional mode-matched Micromachined Vibratory Gyroscopes in open loop operations, namely narrow frequency bandwidths and unstable scale factors. The developed sensor utilizes inherent forcing and inertial nonlinearities from electrostatic forces and fabrication imperfections to auto-parametrically excite the sense mode via 2:1 auto-parametric resonance, which yields a broader bandwidth frequency response for the sensor’s sense mode. The experimental results demonstrated −3 dB frequency bandwidth of 500 Hz, a scale factor of 50 µV/°/s, and a dynamic range of ±330 °/s.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.