Background The current pandemic of the SARS-CoV-2 virus, widely known as COVID-19, has affected millions of people around the world. The World Health Organization (WHO) has recommended vigorous testing to differentiate SARS-CoV-2 from other respiratory infections to aid in guiding appropriate care and management. Situations like this have demanded robust testing strategies and pooled testing of samples for SARS-CoV-2 virus has provided the solution to mass screening of people for COVID-19. A pooled testing strategy can be very effective in testing when resources are limited, yet it comes with its own limitations. These benefits and limitations need critical consideration when it comes to testing highly infectious diseases like COVID-19. Methods This study evaluated the pooled testing of nasopharyngeal swabs for SARS-COV-2 by comparing the sensitivity of individual sample testing with 4-and 8-pool sample testing. Median cycle threshold (Ct) values were compared, and the precision of pooled testing was assessed through an inter- and intra-assay of pooled samples. Coefficient of variance was calculated for inter- and intra-assay variability. Results The sensitivity becomes considerably lower when the samples are pooled. There is a high percentage of false negative reports with larger sample pool size and when the patient viral load is low or weak positive samples. High variability was seen in the intra- and inter-assay, especially among weak positive samples and when more number of samples are pooled together. Conclusion As COVID − 19 infection numbers and need for testing remain high, we must meticulously evaluate the testing strategy for each country depending on its testing capacity, infrastructure, economic strength, and need to determine the optimal balance on the cost-effective strategy of resource saving and risk/ cost of missing positive patients.
In the current coronavirus disease 2019 (COVID‐19) pandemic there is a mass screening of severe acute respiratory syndrome coronavirus 2 (SARS‐CoV‐2) happening around the world due to the extensive spread of the infections. There is a high demand for rapid diagnostic tests to expedite the identification of cases and to facilitate early isolation and control spread. Hence this study evaluates six different rapid nucleic acid detection assays that are commercially available for SARS‐CoV‐2 virus detection. Nasopharyngeal samples were collected from 4981 participants and were tested for the SARS‐CoV‐2 virus by the gold standard real‐time reverse‐transcription polymerase chain reaction (RT‐PCR) method and with one of these six rapid methods of detection. Evaluation of the rapid nucleic acid detection assays was done by comparing the results of these rapid methods with the gold standard RT‐qPCR results for SARS‐COV‐2 detection. AQ‐TOP had the highest sensitivity (98%) and a strong kappa value of 0.943 followed by Genechecker and Abbot ID NOW. The POCKIT (ii RT‐PCR) assay had the highest test accuracy of 99.29% followed by Genechecker and Cobas Liat. Atila iAMP showed the highest percentage of invalid reports (35.5%) followed by AQ‐TOP with 6% and POCKIT with 3.7% of invalid reports. Genechecker system, Abbott ID NOW, and Cobas Liat were found to have the best performance and agreement when compared with the standard RT‐PCR for COVID‐19 detection. With further research, these rapid tests have the potential to be employed in large‐scale screening of COVID‐19.
In this COVID-19 pandemic, there is a dire need for cost-effective and less time-consuming alternatives for SARS-CoV-2 testing. The RNA extraction-free method for detecting SARS-CoV-2 in saliva is a promising option. This study found that it has high sensitivity (85.34%), specificity (95.04%), and was comparable to the gold standard nasopharyngeal swab (NPS) sample tests. The method showed good agreement between salivary and NPS samples, with a kappa coefficient of 0.797. However, there are variations in the sensitivity and specificity based on the RT-PCR kit used. The Thermo Fisher Applied Biosystems showed high sensitivity, positive predictive value (PPV), and negative predictive value (NPV) but also showed a higher percentage of invalid reports. On the other hand, the BGI kit showed high specificity, better agreement (kappa coefficient) between the results of saliva and NPS samples, and higher correlation between the Ct values of saliva and NPS samples. Thus, the RNA extraction-free method for salivary sample serves as an effective alternative screening method for COVID-19.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.