Patients with neurological or orthopedic lesions require assistance during therapies with repetitive movements. NURSE (cassiNo-qUeretaro uppeR-limb aSsistive dEvice) is an arm movement aid device for both right- and left-upper limb. The device has a big workspace to conduct physical therapy or training on individuals including kids and elderly individuals, of any age and size. This paper describes the mechanism design of NURSE and presents a numerical procedure for testing the mechanism feasibility that includes a kinematic, dynamic, and FEM (Finite Element Method) analysis. The kinematic demonstrated that a big workspace is available in the device to reproduce therapeutic movements. The dynamic analysis shows that commercial motors for low power consumption can achieve the needed displacement, acceleration, speed, and torque. Finite Element Method showed that the mechanism can afford the upper limb weight with light-bars for a tiny design. This work has led to the construction of a NURSE prototype with a light structure of 2.6 kg fitting into a box of 35 × 45 × 30 cm. The latter facilitates portability as well as rehabilitation at home with a proper follow-up. The prototype presented a repeatability of ±1.3 cm that has been considered satisfactory for a device having components manufactured with 3D rapid prototyping technology.
Studies have demonstrated the validity of Kinect-based systems to measure spatiotemporal parameters of gait. However, few studies have addressed test-retest, inter-rater and intra-rater reliability for spatiotemporal gait parameters. This study aims to assess test-retest, inter-rater and intra-rater reliability of SANE (eaSy gAit aNalysis system) as a measuring instrument for spatiotemporal gait parameters. SANE comprises a depth sensor and a software that automatically estimates spatiotemporal gait parameters using distances between ankles without the need to manually indicate where each gait cycle begins and ends. Gait analysis was conducted by 2 evaluators for 12 healthy subjects during 4 sessions. The reliability was evaluated using Intraclass Correlation Coefficients (ICC). In addition, the Standard Error of the Measurement (SEM), and Smallest Detectable Change (SDC) was calculated. SANE showed from an acceptable to an excellent test-retest, inter-rater and intra-rater reliability; test-retest reliability ranged from 0.62 to 0.81, inter-rater reliability ranged from 0.70 to 0.95 and intra-rater ranged from 0.74 to 0.92. The subject behavior had a greater effect on the reliability of SANE than the evaluator performance. The reliability values of SANE were comparable with other similar studies. SANE, as a feasible and markerless system, has large potential for assessing spatiotemporal gait parameters.
The efficacy of Lokomat on motor recovery in stroke patients is well known. However, few studies have examined Lokomat tools to assess stiffness, joint torque and range of motion (ROM) during the subacute phase of stroke. The purpose of this retrospective observational study is to assess the changes of joint torque, ROM and stiffness that were estimated with Lokomat tools, namely L-FORCE (lower limb-force), L-ROM (lower limb-range of motion)and L-STIFF (lower limb-stiff), for paretic and non-paretic lower limbs in the subacute phase of stroke, assuming that the tools were able to measure these changes. The data come from 10 subjects in the subacute phase who had their first ever-stroke and followed a treatment that included Lokomat. The measurements came from basal assessments (T0) and one-month follow-up (T1). The measures were compared between paretic and non-paretic legs, and between T0 and T1. Significant differences in stiffness, joint torque and ROM were obtained between the paretic and non-paretic limbs at both T0 and T1. A non-significant trend was obtained for reduced stiffness and increased torque and ROM between T0 and T1 of the paretic limbs. The Lokomat tools were able to measure the changes between paretic and non-paretic legs and the small changes between T0 and T1 measurements.
This paper presents an experimental characterization of NURSE, a device for arm motion guidance. The laboratory setup and testing modes are presented to explain the experimental procedure. Two exercises for the upper limb exercise are used to test the NURSE behaviour, and successful results are presented. Trajectories and linear accelerations are tested when the device performs the two exercises without and with load. In addition, torque and power consumption are considered to check the NURSE behaviour.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.