Peptides of 12 amino acids were tethered via a terminal cysteine to mono-, di-, tri-, and tetrabromomethyl-substituted benzene to produce bundles of one to four peptide strands (CY12-T1 to CY12-T4, respectively). The interaction of the bundles with the α-hemolysin pore was assessed by measuring the blockade currents (I) and times (T) at an applied potential of - 50, - 100, and - 150 mV. Three types of events could be distinguished: bumping events, with small I and short T where the molecule transiently interacts with the pore before diffusing away; translocation events, where the molecule threads through the pore with large I and the value of T decreases with increasing voltage; and intercalation events, where the molecule transiently enters the pore but does not translocate with large I and the value of T increases with increasing voltage. CY12-T1 and CY12-T2 gave only bumping and translocation events; CY12-T3 and CY12-T4 also gave intercalation events, some of which were of very long duration. The results suggest that three uncoiled peptide strands cannot simultaneously thread through the α-hemolysin pore and that proteins must completely unfold in order to translocate.
Nanopore analysis is an emerging technique of structural biology which employs nanopores, such as the α-hemolysin pore, as a biosensor. A voltage applied across a membrane containing a nanopore generates a current, which is partially blocked when a molecule interacts with the pore. The magnitude (I) and the duration (T) of the current blockade provide an event signature for that molecule. Two peptides, CY12(+)T1 and CY12(-)T1 with net charges + 2 and - 2, respectively, were analysed using different applied voltages and all four possible orientations of the electrodes and pore. The four orientations were vestibule downstream (VD), vestibule upstream (VU), stem downstream (SD) and stem upstream (SU) where vestibule and stem refer to the side of the pore on which the peptide was placed and downstream and upstream refer to the application of a positive or negative electrophoretic force, respectively. For CY12(+)T1, the effect of voltage on the event duration was consistent with translocation in the VD and SD configurations, but only intercalation events were observed in the VU and SU configurations. For CY12(-)T1, translocations were only observed in the VD and VU configurations. The results are interpreted in terms of two energy barriers on either side of the lumen of the pore. The difference in height of the barriers determines the preferred direction of exit. Electroosmotic flow and current rectification due to the pore as well as the dipole moment and charge of the peptide also play significant roles. Thus, factors other than simple electrophoresis are important for determining the interaction of small peptides with the pore.
The application of nanopore sensing utilizing the α-hemolysin pore to probe proteins at single-molecule resolution has expanded rapidly. In some studies protein translocation through the α-hemolysin has been reported. However, there is no direct evidence, as yet, that proteins can translocate the α-hemolysin pore. The biggest challenge to obtaining direct evidence is the lack of a highly sensitive assay to detect very low numbers of protein molecules. Furthermore, if an activity based assay is applied then the proteins translocating by unfolding should refold back to an active confirmation for the assay technique to work. To overcome these challenges we selected a model enzyme, ribonuclease A, that readily refolds to an active conformation even after unfolding it with denaturants. In addition we have developed a highly sensitive reverse transcription polymerase chain reaction based activity assay for ribonuclease A. Initially, ribonuclease A, a protein with a positive net charge and dimensions larger than the smallest diameter of the pore, was subjected to nanopore analysis under different experimental conditions. Surprisingly, although the protein was added to the cis chamber (grounded) and a positive potential was applied, the interaction of ribonuclease A with α-hemolysin pore induced small and large blockade events in the presence and the absence of a reducing and/or denaturing agent. Upon measuring the zeta potential, it was found that the protein undergoes a charge reversal under the experimental conditions used for nanopore sensing. From the investigation of the effect of voltage on the interaction of ribonuclease A with the α-hemolysin pore, it was impossible to conclude if the events observed were translocations. However, upon testing for ribonuclease A activity on the trans chamber it was found that ribonuclease A does not translocate the α-hemolysin pore.
Peptide modifications that improve pharmacological properties are of considerable therapeutic importance. Here we consider the retro (R), inversed (D) and retro-inversed (RI) isomers of glucagon with respect to structure, stability, toxicity and biological activity. Biologically, RI-glucagon demonstrated comparable in vivo activity as L-glucagon with respect to magnitude and duration of blood sugar elevation following i.p. administration to mice. Structurally, the isomers were investigated through circular dichroism (CD) and nanopore analysis. CD demonstrated a conserved potential for formation of secondary structure, which was independent of the direction of the peptide (L vs R; D vs RI) as well as formation of symmetry-related structures for the chiral isomers (L vs D; R vs RI). CD, therefore, discriminated chiral but not directional isomers. Nanopore analysis, which depends on interaction of the peptides with chiral pores, discriminated all four isomers on the basis of unique signatures of bumping and translocation. Nanopore analysis offered greater opportunity than CD to discriminate the isomers although neither technique provided a definitive biomarker of biological activity. Functionally, the R and RI isomers resist proteolytic degradation and none of the isomers possess hemolytic activity or cellular toxicity. Collectively, this investigation highlights the potentials and limitations of CD and nanopore analysis for investigation of peptide isomers as well as offering insight into the structural criteria to mimic peptide biological activity. For this example, retro-inversion, through undefined contributions of increased stability and maintained biological activity, was best suited to mimic the biological activity of the parent peptide.
Nanopore analysis is a promising technique for studying the conformation of proteins and protein/protein interactions. Two proteins (bacterial thioredoxin and maltose binding protein) were subjected to nanopore analysis with α-hemolysin. Two types of events were observed; bumping events with a blockade current less than -40 pA and intercalation events with blockade currents between -40 pA and -100 pA. In potassium phosphate buffer, pH 7.8, both proteins gave intercalation events but the frequency of these events was significantly reduced in TRIS or HEPES buffers especially in the presence of 0.01 mM divalent metal ions. The frequency of events was restored by the addition of EDTA. For maltose binding protein, the frequency of intercalation events was also decreased in the presence of maltose but not lactose to which it does not bind. It is proposed that the events with large blockade currents represent transient intercalation of a loop or end of the protein into the pore and that divalent metal ions inhibit this process. The results demonstrate that the choice of buffer and the effects of metal ion contamination are important considerations in nanopore analysis.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.