We have investigated whether restoration of the balance between neutrophil elastase and its inhibitor, alpha(1)-antitrypsin, can prevent the progression of pulmonary emphysema in patients with alpha(1)-antitrypsin deficiency. Twenty-six Danish and 30 Dutch ex-smokers with alpha(1)-antitrypsin deficiency of PI*ZZ phenotype and moderate emphysema (FEV(1) between 30% and 80% of predicted) participated in a double-blind trial of alpha(1)-antitrypsin augmentation therapy. The patients were randomized to either alpha(1)-antitrypsin (250 mg/kg) or albumin (625 mg/kg) infusions at 4-wk intervals for at least 3 yr. Self-administered spirometry performed every morning and evening at home showed no significant difference in decline of FEV(1) between treatment and placebo. Each year, the degree of emphysema was quantified by the 15th percentile point of the lung density histogram derived from computed tomography (CT). The loss of lung tissue measured by CT (mean +/- SEM) was 2.6 +/- 0.41 g/L/yr for placebo as compared with 1.5 +/- 0.41 g/L/yr for alpha(1)-antitrypsin infusion (p = 0.07). Power analysis showed that this protective effect would be significant in a similar trial with 130 patients. This is in contrast to calculations based on annual decline of FEV(1) showing that 550 patients would be needed to show a 50% reduction of annual decline. We conclude that lung density measurements by CT may facilitate future randomized clinical trials of investigational drugs for a disease in which little progress in therapy has been made in the past 30 yr.
EMPIRE10 (Evaluation of Methods for Pulmonary Image REgistration 2010) is a public platform for fair and meaningful comparison of registration algorithms which are applied to a database of intrapatient thoracic CT image pairs. Evaluation of nonrigid registration techniques is a nontrivial task. This is compounded by the fact that researchers typically test only on their own data, which varies widely. For this reason, reliable assessment and comparison of different registration algorithms has been virtually impossible in the past. In this work we present the results of the launch phase of EMPIRE10, which comprised the comprehensive evaluation and comparison of 20 individual algorithms from leading academic and industrial research groups. All algorithms are applied to the same set of 30 thoracic CT pairs. Algorithm settings and parameters are chosen by researchers expert in the configuration of their own method and the evaluation is independent, using the same criteria for all participants. All results are published on the EMPIRE10 website (http://empire10.isi.uu.nl). The challenge remains ongoing and open to new participants. Full results from 24 algorithms have been published at the time of writing. This paper details the organization of the challenge, the data and evaluation methods and the outcome of the initial launch with 20 algorithms. The gain in knowledge and future work are discussed.
FEV(1) is fundamental to the diagnosis and staging of chronic obstructive pulmonary disease. In emphysema, airflow obstruction usually coexists with impairment of gas exchange, but discordance is not infrequent. We hypothesized that variations in the distribution of emphysema would be associated with functional differences and therefore account for discordant physiology. We used quantitative computed tomography to assess emphysema severity and distribution in 119 subjects with alpha1-antitrypsin deficiency (PiZ phenotype) and grouped them according to distribution pattern. In the 102 subjects with emphysema, 65 had a predominantly basal pattern ("basal"), but 37 (36%) had greater involvement of the upper regions ("apical"). Subjects from each group were matched for total volume of emphysema and age, and matched pairs analysis was used to relate emphysema distribution to clinical phenotype. Basal distribution was associated with greater impairment of FEV(1) (mean difference, 9.9% predicted; 95% confidence interval, 3.8 to 16.0; p = 0.002) but less impairment of gas exchange (Pa(O(2)) mean difference, 0.5 kPa, 0.03 to 0.1; p = 0.016) and alveolar-arterial oxygen gradient (mean difference, 0.7 kPa; 0.2 to 1.2; p = 0.007) than the apical distribution. Emphysema distribution correlated with physiologic discordance (r = -0.409, p < 0.001). The use of single physiologic parameters as a surrogate measure of emphysema severity may introduce systematic bias in the staging of subjects with emphysema.
Background-Hypertension is an important clinical problem and is often accompanied by left ventricular (LV) hypertrophy and dysfunction. Whether the myocardial high-energy phosphate (HEP) metabolism is altered in human hypertensive heart disease and whether this is associated with LV dysfunction is not known. Methods and Results-Eleven patients with hypertension and 13 age-matched healthy subjects were studied with magnetic resonance imaging at rest and with phosphorus-31 magnetic resonance spectroscopy at rest and during high-dose atropine-dobutamine stress. Hypertensive patients showed higher LV mass (98Ϯ28 g/m 2 ) than healthy control subjects (73Ϯ13 g/m 2 , PϽ0.01). LV filling was impaired in patients, reflected by a decreased peak rate of wall thinning (PRWThn), E/A ratio, early peak filling rate, and early deceleration peak (all PϽ0.05), whereas systolic function was still normal. The myocardial phosphocreatine (PCr)/ATP ratio determined in patients at rest (1.20Ϯ0.18) and during stress (0.95Ϯ0.25) was lower than corresponding values obtained from healthy control subjects at rest (1.39Ϯ0.17, PϽ0.05) and during stress (1.16Ϯ0.18, PϽ0.05). The PCr/ATP ratio correlated significantly with PRWThn (rϭϪ0.55, PϽ0.01), early deceleration peak (rϭϪ0.56, PϽ0.01), and with the rate-pressure product (rϭϪ0.53, PϽ0.001). Conclusions-Myocardial HEP metabolism is altered in patients with hypertensive heart disease. In addition, there is an association between impaired LV diastolic function and altered myocardial HEP metabolism in humans.
BackgroundTwo randomised, double-blind, placebo-controlled trials have investigated the efficacy of IV alpha-1 antitrypsin (AAT) augmentation therapy on emphysema progression using CT densitometry.MethodsData from these similar trials, a 2-center Danish-Dutch study (n = 54) and the 3-center EXAcerbations and CT scan as Lung Endpoints (EXACTLE) study (n = 65), were pooled to increase the statistical power. The change in 15th percentile of lung density (PD15) measured by CT scan was obtained from both trials. All subjects had 1 CT scan at baseline and at least 1 CT scan after treatment. Densitometric data from 119 patients (AAT [Alfalastin® or Prolastin®], n = 60; placebo, n = 59) were analysed by a statistical/endpoint analysis method. To adjust for lung volume, volume correction was made by including the change in log-transformed total lung volume as a covariate in the statistical model.ResultsMean follow-up was approximately 2.5 years. The mean change in lung density from baseline to last CT scan was -4.082 g/L for AAT and -6.379 g/L for placebo with a treatment difference of 2.297 (95% CI, 0.669 to 3.926; p = 0.006). The corresponding annual declines were -1.73 and -2.74 g/L/yr, respectively.ConclusionsThe overall results of the combined analysis of 2 separate trials of comparable design, and the only 2 controlled clinical trials completed to date, has confirmed that IV AAT augmentation therapy significantly reduces the decline in lung density and may therefore reduce the future risk of mortality in patients with AAT deficiency-related emphysema.Trial registrationThe EXACTLE study was registered in ClinicalTrials.gov as 'Antitrypsin (AAT) to Treat Emphysema in AAT-Deficient Patients'; ClinicalTrials.gov Identifier: NCT00263887.
The VESSEL12 (VESsel SEgmentation in the Lung) challenge objectively compares the performance of different algorithms to identify vessels in thoracic computed tomography (CT) scans. Vessel segmentation is fundamental in computer aided processing of data generated by 3D imaging modalities. As manual vessel segmentation is prohibitively time consuming, any real world application requires some form of automation. Several approaches exist for automated vessel segmentation, but judging their relative merits is difficult due to a lack of standardized evaluation. We present an annotated reference dataset containing 20 CT scans and propose nine categories to perform a comprehensive evaluation of vessel segmentation algorithms from both academia and industry. Twenty algorithms participated in the VESSEL12 challenge, held at International Symposium on Biomedical Imaging (ISBI) 2012. All results have been published at the VESSEL12 website http://vessel12.grand-challenge.org. The challenge remains ongoing and open to new participants. Our three contributions are: (1) an annotated reference dataset available online for evaluation of new algorithms; (2) a quantitative scoring system for objective comparison of algorithms; and (3) performance analysis of the strengths and weaknesses of the various vessel segmentation methods in the presence of various lung diseases.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.