BackgroundA standardized imaging proposal evaluating implanted left atrial appendage (LAA) occlusion devices by cardiac computed tomography angiography (cCTA) has never been investigated.MethodscCTA datasets were acquired on a 3rd generation dual-source CT system and reconstructed with a slice thickness of 0.5 mm. An interdisciplinary evaluation was performed by two interventional cardiologists and one radiologist on a 3D multi-planar workstation. A standardized multi-planar reconstruction algorithm was developed in order to assess relevant clinical aspects of implanted LAA occlusion devices being outlined within a pictorial essay.ResultsThe following clinical aspects of implanted LAA occlusion devices were evaluated within the most appropriate cCTA multi-planar reconstruction: (1) topography to neighboring structures, (2) peri-device leaks, (3) coverage of LAA lobes, (4) indirect signs of neo-endothelialization. These are illustrated within concise CT imaging examples emphasizing the potential value of the proposed cCTA imaging algorithm: Starting from anatomical cCTA planes and stepwise angulation planes perpendicular to the base of the LAA devices generates an optimal LAA Occluder View for post-implantation Evaluation (LOVE). Aligned true axial, sagittal and coronal LOVE planes offer a standardized and detailed evaluation of LAA occlusion devices after percutaneous implantation.ConclusionsThis pictorial essay presents a standardized imaging proposal by cCTA using multi-planar reconstructions that enables systematical follow-up and comparison of patients after LAA occlusion device implantation.Electronic supplementary materialThe online version of this article (doi:10.1186/s12880-016-0127-y) contains supplementary material, which is available to authorized users.
INTRODUCTION Central venous catheterisation (CVC) is a commonly performed procedure in a wide variety of hospital settings and is associated with appreciable morbidity. There is a paucity of literature focusing on mechanical complications specifically in the trauma setting. The aim of our study was to determine the spectrum of mechanical complications in a high-volume trauma centre in a developing world setting where ultrasound guidance was not available. METHODS A retrospective study was performed analysing data from a four-year period at the Pietermaritzburg Metropolitan Trauma Service in South Africa. RESULTS A total of 178 mechanical complications (18%) occurred in 1,015 patients undergoing CVC: 117 pneumothoraces, 25 malpositions, 18 catheter dislodgements, 14 arterial cannulations, one air embolism, one chylothorax, one pleural cannulation and one retained guide-wire. The internal jugular vein (IJV) approach was associated with a higher overall complication rate than the subclavian vein (SCV) approach (24% vs. 13%, p<0.001). Pneumothorax (73% vs. 57%, p<0.001) and arterial cannulation (15% vs. 0%, p<0.001) were more common with the IJV. Catheter dislodgement (21% vs. 0%, p<0.001) was more common with the SCV. Junior doctors performed 66% of the CVCs and this was associated with a significantly higher complication rate (20% vs. 12%, p<0.001). CONCLUSIONS CVC carries appreciable morbidity, with pneumothorax being the most frequent mechanical complication. The SCV was the most commonly used approach at our institution. The majority of CVCs were performed by junior doctors and this was associated with a considerable complication rate.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.