Clinical magnetic resonance imaging (MRI) sequences are not often capable of directly visualizing tendons. Ultrashort echo time (UTE) MRI can acquire high signal from tendons thus enabling quantitative assessments. Magnetization transfer (MT) modeling combined with UTE-MRI—UTE-MT-modeling—can indirectly assess macromolecular protons in the tendon. This study aimed to determine if UTE-MT-modeling is a quantitative technique sensitive to the age-related changes of tendons. The legs of 26 young healthy (29 ± 6 years old) and 22 elderly (75 ± 8 years old) female subjects were imaged using UTE sequences on a 3T MRI scanner. Institutional review board approval was obtained, and all recruited subjects provided written informed consent. T1 and UTE-MT-modeling were performed on anterior tibialis tendons (ATT) and posterior tibialis tendons (PTT) as two representative human leg tendons. A series of MT pulse saturation powers (500–1500°) and frequency offsets (2–50 kHz) were used to measure the macromolecular fraction (MMF) and macromolecular T2 (T2MM). All measurements were repeated by three independent readers for a reproducibility study. MMF demonstrated significantly lower values on average in the elderly cohort compared with the younger cohort for both ATT (decreased by 16.8%, p = 0.03) and PTT (decreased by 23.0%, p < 0.01). T2MM and T1 did not show a significant nor a consistent difference between the young and elderly cohorts. For all MRI parameters, intraclass correlation coefficient (ICC) was higher than 0.98, indicating excellent consistency between measurements performed by independent readers. MMF serving as a surrogate measure for collagen content, showed a significant decrease in elderly leg tendons. This study highlighted UTE-MRI-MT techniques as a useful quantitative method to assess the impact of aging on human tendons.
Purpose: To investigate the correlations between cortical bone microstructural properties and total water proton density (TWPD) obtained from three-dimensional ultrashort echo time Cones (3D-UTE-Cones) magnetic resonance imaging techniques.Materials and Methods: 135 cortical bone samples were harvested from human tibial and femoral midshafts of 37 donors (61±24 years old). Samples were scanned using 3D-UTE-Cones sequences on a clinical 3T MRI and on a high-resolution micro-computed tomography (μCT) scanner. TWPD was measured using 3D-UTE-Cones MR images. Average bone porosity, pore size, and bone mineral density (BMD) were measured from μCT images at 9 μm voxel size. Pearson's correlation coefficients between TWPD and μCT-based measures were calculated.Results: TWPD showed significant moderate correlation with both average bone porosity (R=0.66, p<0.01) and pore size (R=0.58, p<0.01). TWPD also showed significant strong correction with BMD (R=0.71, p<0.01).
Conclusions:The presented 3D-UTE-Cones imaging technique allows assessment of TWPD in human cortical bone. This quick UTE-MRI-based technique was capable of predicting bone microstructure differences with significant correlations. Such correlations highlight the potential of UTE-MRI-based measurement of bone water proton density to assess bone microstructure.
Conventional magnetic resonance imaging (MRI) often acquires no signal in anterior cruciate ligament (ACL) due to the short apparent transverse relaxation time of ACL. Ultrashort echo time (UTE) MRI is capable of imaging ACL with high signal which enables quantitative ACL assessment. This study aimed to investigate the correlations of the mechanical and microstructural properties of human ACL specimens with quantitative three‐dimensional UTE Cones (3D‐UTE‐Cones) MRI measures. ACL specimens were harvested from cadaveric knee joints of 13 (50.9 ± 21.1 years old, 11 males and 2 female) donors. Specimens were scanned using a series of quantitative 3D‐UTE‐Cones T2* (UTE‐T2*), T1 (UTE‐T1), Adiabatic T1ρ (UTE‐Adiab‐T1ρ), and magnetization transfer (UTE‐MT) sequences in a wrist coil on a clinical 3T scanner. ACL elastic modulus was measured using a uniaxial tensile mechanical test. Histomorphometry analysis was performed to measure the average fascicle specific surface, fascicle size, and number of cells per unit area. Spearman's rank correlations of UTE‐MRI biomarkers with mechanical and histomorphometry measures were investigated. The elastic modulus of ACL showed significant moderate correlations with UTE‐Adiab‐T1ρ (R = −0.59, p = 0.01), macromolecular fraction from MT modeling (R = 0.54, p = 0.01), magnetization transfer ratio (R = 0.53, p = 0.01), UTE‐T2* (R = −0.53, p = 0.01), and average fascicle specific surface (R = 0.54, p = 0.01). UTE‐MRI showed nonsignificant correlations with histomorphometry measures. UTE‐MRI biomarkers may be useful noninvasive tools for the ACL mechanical assessment.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.